User:Karlena L. Brown/Notebook/PVOH Research/2012/10/31: Difference between revisions
From OpenWetWare
(→Notes) |
|||
Line 108: | Line 108: | ||
==Notes== | ==Notes== | ||
* The varied ion concentrated solution contained the following ions: Chlorine (Cl<sup>-</sup>), Bromine (Br<sup>-</sup>), and Iodine (I<sup>-</sup>). | * The varied ion concentrated solution contained the following ions: Chlorine (Cl<sup>-</sup>), Bromine (Br<sup>-</sup>), and Iodine (I<sup>-</sup>). | ||
* μS/cm ( | * μS/cm (microsiemen per centimeter) is a conductivity unit of measurement that is the inverse of an Ohm (O). | ||
* Experimental readings regarding the Ion Selective Electrode Analysis were taken every 30 minutes; however, for the first reading and recording only a 10 min interval surpassed before a reading was taken. | * Experimental readings regarding the Ion Selective Electrode Analysis were taken every 30 minutes; however, for the first reading and recording only a 10 min interval surpassed before a reading was taken. | ||
* The final two readings germane to the Ion Selective Electrode Analysis for the PVOH 22K film containing 1mL glutaldehyde that was exchanged for 10 min with CuSO<sub>4</sub> were taken by Dr. Fox. | * The final two readings germane to the Ion Selective Electrode Analysis for the PVOH 22K film containing 1mL glutaldehyde that was exchanged for 10 min with CuSO<sub>4</sub> were taken by Dr. Fox. |
Revision as of 02:47, 24 November 2012
PVOH Research | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OBJECTIVES
Furfural Film Preparation
(PVOH 22K Actual Mass = 1.0029g)
(Furfural Actual Mass = 0.3192g)
Films Examined using FTIRRECALL FTIR PROCEDURAL PROTOCOL 9/17/12 Ion Diffusion & Ion Selective Electrode Film Procedures
Ensure the hole separating the two graduated cylinder columns is completely shielded and covered by the PVOH 22K film ISE Film Analysis: Varied Ion SolutionA crosslinked PVOH 22K film containing 1mL glutaldehyde that had been exchanged for 10 min in the CuSO4 solution was used for an Ion Selective Electrode Analysis.
ISE Film Analysis: HPLC Grade H2O SolutionA crosslinked PVOH 22K film containing 1mL glutaldehyde that had been exchanged for 10 min in the CuSO4 solution was used for an Ion Selective Electrode Analysis.
Notes
|