7-AAD: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(New page: 7-aminoactinomycin-D * 546/647 * Nucleic acid dye * Stains '''dead cells''' * "The advantage of 7-AAD over PI is the ability to be used in conjunction with phycoerythrin (PE)- and fluores...)
 
m (categories)
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
7-aminoactinomycin-D
7-aminoactinomycin-D


==Purpose==
* Staining '''dead cells'''
==Procurement==
* Most standard companies
** [http://www.bdbiosciences.com/ptProduct.jsp?prodId=12856 BD Biosciences]
** [http://www.ebioscience.com/ebioscience/specs/antibody_00/00-6993.htm eBioscience]
==Use==
* 546/647
* 546/647
* Nucleic acid dye
* Nucleic acid dye
* Stains '''dead cells'''
* Often used in conjunction with [[Annexin-V]] when assaying for apoptotic cells
* "The advantage of 7-AAD over PI is the ability to be used in conjunction with phycoerythrin (PE)- and fluorescein isothiocyanate (FITC)-labeled monoclonal antibodies in 2-color analysis, with minimal spectral overlap between 7-AAD, PE and FITC fluorescence emissions. The 7-AAD fluorescence is detected in the '''far red range''' of the spectrum (650 nm long-pass filter).
* "The '''advantage of 7-AAD''' over PI is the ability to be used '''in conjunction with''' phycoerythrin ('''PE''')- '''and''' fluorescein isothiocyanate ('''FITC''')-labeled monoclonal antibodies in 2-color analysis, with minimal spectral overlap between 7-AAD, PE and FITC fluorescence emissions. The 7-AAD fluorescence is detected in the '''far red range''' of the spectrum (650 nm long-pass filter).
 
==Safety==
* No significant safety considerations ([http://www.bdbiosciences.com/external_files/pm/doc/msds/live/web_enabled/559925-MSDS.01.pdf BD Biosciences MSDS Sheet])
 
==References==
* MC O’Brien, et al. (1995) Cytometry 19:243
* I Schmid et al. (1992) Cytometry 13:204
 
<!-- ==Contact==
 
Add any other categories that may be relevant to your page.  We use categories like tags.
-->
 
[[Category:Material]] [[Category:Dye]] [[Category:Viability dye]]

Latest revision as of 06:30, 5 May 2009

7-aminoactinomycin-D

Purpose

  • Staining dead cells

Procurement

Use

  • 546/647
  • Nucleic acid dye
  • Often used in conjunction with Annexin-V when assaying for apoptotic cells
  • "The advantage of 7-AAD over PI is the ability to be used in conjunction with phycoerythrin (PE)- and fluorescein isothiocyanate (FITC)-labeled monoclonal antibodies in 2-color analysis, with minimal spectral overlap between 7-AAD, PE and FITC fluorescence emissions. The 7-AAD fluorescence is detected in the far red range of the spectrum (650 nm long-pass filter).

Safety

References

  • MC O’Brien, et al. (1995) Cytometry 19:243
  • I Schmid et al. (1992) Cytometry 13:204