==Descriptive Stats and Graph==
==Descriptive and Inferential Stats and Graphs==


<br><br>
'''Heart Rate of Pulse Ox and Spree'''


==Inferential Stats==
[[image:L3HRBarGraph.png]][[image:Improved Heart Rate.png]]<br>


Gold Standard:<br>
Average: 98.08976898<br>
Standard Deviation: 23.03054395<br>
<br>
Correlation Coefficient: 0.19287301522<br>
T-Test P-Value: 0.427116193<br>
<br>
Spree:<br>
Average: 98.95379538<br>
Standard Deviation: 24.87753802<br>
<br>


'''Temperature of Gold Standard and Spree'''<br>


[[image: The Real Temperature Graph.png]][[image:Temp Scatter.png]]<br>


Gold Standard:<br>         
Average: 96.64716049<br>                             
Standard Deviation: 1.922602071<br>
<br>
Correlation Coefficient: 0.69079664156<br>
T-Test P-Value: 1.09676E-21<br>
<br>                   
Spree:<br>
Average: 95.5308642<br>
Standard Deviation: 0.870378299<br>
<br>


<br><br>
==Summary of Results==
 
'''Heart Rate of Pulse Ox and Spree'''<br>
Based on the results of the scatter plot for the average heart rate (in beats per minute), there is a weak, positive correlation (R = 0.193) between the Spree model and the Gold Standard. Upon calculating a t-test between the two devices, the results were found to be significant at the  α = 0.05 significance level since the Spree model had a p-value of about 1.097E-21. This data provides convincing evidence that the Spree can accurately measure the average heart rate of humans.
 
'''Temperature of Oral Thermometer and Spree'''<br>
Based on the results of the scatter plot for the average temperature, there is a strong, positive correlation (R = 0.691) between the Spree model and the Gold Standard. Upon calculating a t-test between the two devices, the Spree model had a p-value of about 0.427. From this, there is not convincing evidence that, at the α = 0.05 significance level, the Spree model is comparable to the Gold Standard in recording the average human body temperature, meaning it is not accurate.
<br>


==Design Flaws and Recommendations==
==Design Flaws and Recommendations==
Based on the data above, the spree device is not a very specific and adequate way of measuring a person’s temperature and heart rate.
One possible design flaw for this experiment is that the trial did not use random sampling. The trial took place on a college campus, therefore, the majority of the people participating would have a healthy heart rate. If the trial used random sampling, there would be people of all ages participating in the trial. Therefore, the data of average heart rate would be significantly more accurate.
Another possible design flaw in this experiment would be the use of the oral thermometer. Using an oral thermometer to take a person's temperature is not very accurate. A better alternative for checking the participant's temperature would be through a digital thermometer or an ear thermometer. The digital thermometer uses electronic heat sensors to measure the body's temperature. This is much more precise than an oral thermometer. Using an oral thermometer averages about .5 degrees F to 1.0 degrees F below rectal, ear, and temporal readings, but not only that, but taking oral temperatures after eating or drinking also affect the accuracy of the sample.




Works Cited:


"Thermometers: Understand the Options." Mayo Clinic. Mayo Foundation for Medical Education and Research, 12 Sept. 2015. Web.


Tousseau, Jennifer. “What Is the Most Accurate Way to Take a Temperature? Is Oral, Temporal, Ear, or Rectal Best?” Systemic Autoinflammatory Disease (SAID) Support, 13 May 2017, saidsupport.org/what-is-the-most-accurate-way-to-take-a-temperature-is-oral-temporal-ear-or-rectal-best/.
<br>


<br><br>
==Experimental Design of Own Device==


==Experimental Design of Own Device==<br>
For the thermal therapy device, multiple temperatures will be taken in order to prove consistency. The goal is for the device to have 95% precision rate in achieving a target temperature. The data will be collected using a separate thermometer, and recorded on an excel sheet. The standard deviation for this experiment is expected to be fairly large (s = due to the fact that it will be both heating and cooling, which would increase the spread between all of the data points. The average value of the data would be larger as well because of the variation in temperature. The correlation of the data would be positive because the temperature goes from low to high and vice versa. In the trial, random sampling would be applied. From every state in the US, two physical therapy offices will be chosen at random and from each of these offices one patient will be chosen to participate in the trial. Having the sample spread out across the country makes the sample fairly representative of the American population that uses heating or cooling pads to treat chronic pain.


For the thermal therapy device, multiple different temperatures will be taken in order to prove consistency. The goal is for the device to get as close to the desired temperature as possible. The data will be recorded through a separate thermometer on the excel sheet. The standard deviation for this experiment would be much bigger due to the fact that it will be both heating and cooling. The average of the data would be larger as well because of the variation in temperature. The correlation of the data would be positive because the temperature goes from low to high and vice versa.<br>
From every state in the US, two physical therapy offices will be chosen at random and from each of these offices one patient will be chosen to participate in the trial. Thus making the trials more representative of the population, more specifically involving Americans who use heating or cooling pads to treat chronic pain. The participants would use the device for a period of three weeks. In that time, they will record how the temperature of the device feels and what their level of chronic pain is from the beginning to the end of the three weeks. They will rank their pain levels once a day. This way, by the end of the three weeks, they will be able to look back on their progress throughout the trial. <br>


<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
|}
|}

Latest revision as of 23:14, 27 September 2017

BME 100 Fall 2017 Home
People
Lab Write-Up 1 | Lab Write-Up 2 | Lab Write-Up 3
Lab Write-Up 4 | Lab Write-Up 5 | Lab Write-Up 6
Course Logistics For Instructors
Photos
Wiki Editing Help


OUR TEAM

Cole Alvarez
Kylie I. Mercer
Nathan Moorman
Kassandra Sanchez
Lauren Seliger

LAB 3 WRITE-UP

Descriptive and Inferential Stats and Graphs

Heart Rate of Pulse Ox and Spree


Gold Standard:
Average: 98.08976898
Standard Deviation: 23.03054395

Correlation Coefficient: 0.19287301522
T-Test P-Value: 0.427116193

Spree:
Average: 98.95379538
Standard Deviation: 24.87753802

Temperature of Gold Standard and Spree


Gold Standard:
Average: 96.64716049
Standard Deviation: 1.922602071

Correlation Coefficient: 0.69079664156
T-Test P-Value: 1.09676E-21

Spree:
Average: 95.5308642
Standard Deviation: 0.870378299

Summary of Results

Heart Rate of Pulse Ox and Spree
Based on the results of the scatter plot for the average heart rate (in beats per minute), there is a weak, positive correlation (R = 0.193) between the Spree model and the Gold Standard. Upon calculating a t-test between the two devices, the results were found to be significant at the α = 0.05 significance level since the Spree model had a p-value of about 1.097E-21. This data provides convincing evidence that the Spree can accurately measure the average heart rate of humans.

Temperature of Oral Thermometer and Spree
Based on the results of the scatter plot for the average temperature, there is a strong, positive correlation (R = 0.691) between the Spree model and the Gold Standard. Upon calculating a t-test between the two devices, the Spree model had a p-value of about 0.427. From this, there is not convincing evidence that, at the α = 0.05 significance level, the Spree model is comparable to the Gold Standard in recording the average human body temperature, meaning it is not accurate.

Design Flaws and Recommendations

Based on the data above, the spree device is not a very specific and adequate way of measuring a person’s temperature and heart rate.

One possible design flaw for this experiment is that the trial did not use random sampling. The trial took place on a college campus, therefore, the majority of the people participating would have a healthy heart rate. If the trial used random sampling, there would be people of all ages participating in the trial. Therefore, the data of average heart rate would be significantly more accurate.

Another possible design flaw in this experiment would be the use of the oral thermometer. Using an oral thermometer to take a person's temperature is not very accurate. A better alternative for checking the participant's temperature would be through a digital thermometer or an ear thermometer. The digital thermometer uses electronic heat sensors to measure the body's temperature. This is much more precise than an oral thermometer. Using an oral thermometer averages about .5 degrees F to 1.0 degrees F below rectal, ear, and temporal readings, but not only that, but taking oral temperatures after eating or drinking also affect the accuracy of the sample.


Works Cited:

"Thermometers: Understand the Options." Mayo Clinic. Mayo Foundation for Medical Education and Research, 12 Sept. 2015. Web.

Tousseau, Jennifer. “What Is the Most Accurate Way to Take a Temperature? Is Oral, Temporal, Ear, or Rectal Best?” Systemic Autoinflammatory Disease (SAID) Support, 13 May 2017, saidsupport.org/what-is-the-most-accurate-way-to-take-a-temperature-is-oral-temporal-ear-or-rectal-best/.

Experimental Design of Own Device

For the thermal therapy device, multiple temperatures will be taken in order to prove consistency. The goal is for the device to have 95% precision rate in achieving a target temperature. The data will be collected using a separate thermometer, and recorded on an excel sheet. The standard deviation for this experiment is expected to be fairly large (s = due to the fact that it will be both heating and cooling, which would increase the spread between all of the data points. The average value of the data would be larger as well because of the variation in temperature. The correlation of the data would be positive because the temperature goes from low to high and vice versa. In the trial, random sampling would be applied. From every state in the US, two physical therapy offices will be chosen at random and from each of these offices one patient will be chosen to participate in the trial. Having the sample spread out across the country makes the sample fairly representative of the American population that uses heating or cooling pads to treat chronic pain.

From every state in the US, two physical therapy offices will be chosen at random and from each of these offices one patient will be chosen to participate in the trial. Thus making the trials more representative of the population, more specifically involving Americans who use heating or cooling pads to treat chronic pain. The participants would use the device for a period of three weeks. In that time, they will record how the temperature of the device feels and what their level of chronic pain is from the beginning to the end of the three weeks. They will rank their pain levels once a day. This way, by the end of the three weeks, they will be able to look back on their progress throughout the trial.