BME103:T130 Group 7: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
 
(30 intermediate revisions by 5 users not shown)
Line 13: Line 13:
{| style="wikitable" width="700px"
{| style="wikitable" width="700px"
|- valign="top"
|- valign="top"
| [[Image:cheesemouse.jpg|100px|thumb|Name: Emily Thompson<br>Research & Development Scientist]]
| [[Image:EmilyBMElab.jpg|100px|thumb|Name: Emily Thompson<br>Research & Development Scientist]]
| [[Image:strongham.jpg|100px|thumb|Name: Vivian Benjes<br>Experimental Protocol Planner]]
| [[Image:strongham.jpg|100px|thumb|Name: Vivian Benjes<br>Experimental Protocol Planner/ Data Analyst]]
| [[Image:bananafran.jpg|100px|thumb|Name: Frances Marrett<br>Experimental Protocol Planner]]
| [[Image:bananafran.jpg|100px|thumb|Name: Frances Marrett<br>Experimental Protocol Planner]]
| [[Image:cglass.jpg|100px|thumb|Name: Chris Glass<br>Open PCR Machine Engineer<br>[http://openwetware.org/wiki/User:Christopher_M._Glass]]]
| [[Image:ChrisBMElab.jpg|100px|thumb|Name: [http://openwetware.org/wiki/User:Christopher_M._Glass Chris Glass]<br>Open PCR Machine Engineer<br>]]
| [[Image:moose.jpg|100px|thumb|Name: Ryan Frantz<br>Open PCR Machine Engineer<br>[http://openwetware.org/wiki/User:Ryan_T._Frantz]]]
| [[Image:RyanBMElab.jpg|100px|thumb|Name: Ryan Frantz<br>Open PCR Machine Engineer<br>[http://openwetware.org/wiki/User:Ryan_T._Frantz]]]
| [[Image:puffer.jpg|100px|thumb|Name: Cenric Nigbur<br>Ghost/ TBD]]
| [[Image:puffer.jpg|100px|thumb|Name: Cenric Nigbur<br>Ghost/ TBD]]
|}
|}
Line 27: Line 27:


'''The Original Design'''<br>
'''The Original Design'''<br>
This is a PCR (polymerase chain reaction) machine (model: Open PCR 1 Jankowski and Perfetto). This machine is capable of replicating DNA through a series of temperature changes over timed cycles. It uses specialized primers to target specific gene sequences and is capable of amplifying singular stretches of DNA. <br>
This is a PCR (polymerase chain reaction) machine ([http://openpcr.org/ Open PCR 1 Jankowski and Perfetto]). This machine is capable of replicating DNA through a series of temperature changes over timed cycles. It uses specialized primers to target specific gene sequences and is capable of amplifying singular stretches of DNA. <br>


[[Image:PCR Machine.png]]
[[Image:PCR Machine.png]]
Line 36: Line 36:
When the PCB board was unplugged from the Open PCR circuit board, the machine's LED display ceased to function.
When the PCB board was unplugged from the Open PCR circuit board, the machine's LED display ceased to function.


When the white wire that connects the Open PCR circuit board to 16 tube PCR block was unplugged, the machine's LED display read -40 Celsius indicating that the temperature could not be read.  
When the white wire that connects the Open PCR circuit board to the 16 tube PCR block was unplugged, the machine's LED display read -40 Celsius. This most likely indicated that the temperature could not be read on the device and that it was instead displaying a null value for the temperature.  




'''Test Run'''
'''Test Run'''


October 18,2012; The test program labeled "Simple Test", was performed to ensure proper function of the Open PCR machine. It ran through two cycles at a full range of temperatures, no DNA was present for the test run. The test performed without any flaws.<br>
October 18,2012; The test program labeled "Simple Test", was performed on machine number 7 to ensure proper function of the Open PCR machine. It ran through two cycles at a full range of temperatures and tested all of the PCR machine's essential systems. No DNA was present for the test run. The test performed without any flaws and the machine proved to be fairly quick at reaching its desired temperature.<br>




Line 57: Line 57:


To analyze the DNA samples after they've been amplified,  
To analyze the DNA samples after they've been amplified,  
a smartphone with adjustable settings was used.<br>
a smartphone with adjustable settings was used to take a photo of the samples.<br>
These settings were used and the provided cradle was implemented to hold the phone in position for photographing:<br>
These settings were used to accentuate the DNA smaples and a cradle was implemented to hold the phone in position for photographing:<br>


- Exposure to highest setting <br>
- Exposure to highest setting <br>
Line 68: Line 68:
<br><br>
<br><br>


The Fluorimeter aparatus consists of a hydrophobic Teflon surface on a glass slide. There is an array of 3x10 glass wells on the surface to anchor drops in position for photographing. First, two drops of the cybergreen solution were placed on row 2, column 1&2 (Figure 1). With a sterile pipet two drops of amplified sample DNA were added to the cybergreen solution. It was important to place the DNA on top of the cybergreen in order to achieve the best results and to avoid contamination of the DNA samples. The picture was then photographed in the dark box with the door shut to eliminate excess background light. The next sample was prepared by sucking the liquid off the slide using a 'waste' pipet. The slide was then moved back by two columns for the next sample. This procedure was replicated for each of the patient samples and two slides were used in their entirety. <br> <br>
The Fluorimeter aparatus consists of a hydrophobic Teflon surface on a glass slide. There is an array of 3x10 glass wells on the surface to anchor drops in position for photographing. First, two drops of the [http://en.wikipedia.org/wiki/SYBR_Green_I cybergreen] solution were placed on row 2, column 1&2 (Figure 1). With a sterile pipet two drops of amplified sample DNA were added to the cybergreen solution. It was important to place the DNA on top of the cybergreen in order to achieve the best results and to avoid contamination of the DNA samples. The picture was then photographed in the dark box with the door shut to eliminate excess background light. The next sample was prepared by sucking the liquid off the slide using a 'waste' pipet. The slide was then moved back by two columns for the next sample. This procedure was replicated for each of the patient samples and two slides were used in their entirety. <br> <br>
Picture and Analysis: <br>
 
'''Picture and Analysis:''' <br>
 
The pictures of each sample were analyzed using the "image j" software to process the images and analyze their content. The pictures, taken with the settings listed above, were upload to the "image j" software. The images were then separated into their composite colors, red, blue, and green. The green portion of the images were then analyzed using the software and its "INTDEN" was recorded.
The pictures of each sample were analyzed using the "image j" software to process the images and analyze their content. The pictures, taken with the settings listed above, were upload to the "image j" software. The images were then separated into their composite colors, red, blue, and green. The green portion of the images were then analyzed using the software and its "INTDEN" was recorded.






Interpreting results:
'''Interpreting results:'''


The cybergreen soluiton allowed the amount of DNA in a sample to be determined by its "INTDEN". The cybergreen glowed green in the presence of DNA and while this glow was not visable to the naked eye, the smart phone in conjunction with "image j" was able to quantify the luminosity in terms of the "INTDEN". The brighter samples contained more DNA and had a higher "INTDEN" value. This indicated that the sample reacted with the primers better and was cancerous.
The cybergreen soluiton allowed the amount of DNA in a sample to be determined by its "INTDEN". The cybergreen glowed green in the presence of DNA and while this glow was not visable to the naked eye, the smart phone in conjunction with "image j" was able to quantify the luminosity in terms of the "INTDEN". The brighter samples contained more DNA and had a higher "INTDEN" value. This indicated that the sample reacted with the primers better and was cancerous.
Line 82: Line 84:
'''Specific Cancer Marker Detection - The Underlying Technology'''<br>
'''Specific Cancer Marker Detection - The Underlying Technology'''<br>


Polymerase Chain Reaction, or PCR, is used to ampllify a specific segment of DNA, in this case the segment known to code for cancer. A primer, which is an artifically synthesized piece of complementary DNA, binds to the desired DNA segment, and the enzyme taq polymerase catalyzes the replication of the DNA strand using dNTPs (free bases). This is repeated over and over to produce many copies of the DNA. Once the copies are made, a fluorescent dye that only bonds to DNA double strands is added to the solution. If a solution that shows fluorescence by using a fluorimeter, then that DNA sample contains the cancer-associated sequence.  <br>
[http://www.ncbi.nlm.nih.gov/projects/genome/probe/doc/TechPCR.shtml Polymerase Chain Reaction], or PCR, is used to ampllify a specific segment of DNA, in this case the segment known to code for cancer. A primer, which is an artifically synthesized piece of complementary DNA, binds to the desired DNA segment, and the enzyme taq polymerase catalyzes the replication of the DNA strand using dNTPs (free bases). This is repeated over and over to produce many copies of the DNA. Once the copies are made, a fluorescent dye that only bonds to DNA double strands is added to the solution. If a solution that shows fluorescence by using a fluorimeter, then that DNA sample contains the cancer-associated sequence.  <br>


The single nucleotide polymorphism, or SNP, that is linked to cancer is rs17879961. The DNA base sequence associated with cancer is ACT, while the non-cancer sequence is ATT. PCR works to identify ACT from ATT because the primers, which are complementary to DNA strands containing cancer-positive ACT, will not bind to DNA containing ATT, and instead of DNA double strands, the solution will only contain single strands. The fluorescent dye will only bind to double strands and will identify those. <br>
The single nucleotide polymorphism, or SNP, that is linked to cancer is [http://www.ncbi.nlm.nih.gov/SNP/snp_ref.cgi?rs=17879961 rs17879961]. The DNA base sequence associated with cancer is ACT, while the non-cancer sequence is ATT. PCR works to identify ACT from ATT because the primers, which are complementary to DNA strands containing cancer-positive ACT, will not bind to DNA containing ATT, and instead of DNA double strands, the solution will only contain single strands. The fluorescent dye will only bind to double strands and will identify those. <br>




[[Image:EmilyPCRpic.jpg|700px]]<br>
[[Image:EmilyPCRpic.jpg|700px]]<br>
Adapted from: http://users.ugent.be/~avierstr/principles/pcr.html <br>
Adapted from: http://users.ugent.be/~avierstr/principles/pcr.html <br><br><br>
 
Reliability through Bayes Law <br>
 
Bayes Law expresses the probability that something is true. In this case, it relates to the probability that a person testing positive for cancer markers actually has cancer.


<br><br>
           
:<math>P(A|X) = \frac{P(X|A) P(A)}{P(X)} = \frac{P(X|A) P(A)}{P(X|A) P(A) + P(X|notA) P(notA)}</math>
 
Bayes Law states that the probability of an event, A, given another event, X, is equal to the probability of X given A times the probability of A. This is then divided by the probability of X given A times the probability of A plus the probability of X given not A times the probability of not A.
In the case of the cancer markers, events A and X might be the probability that a patient has cancer given that the patient tested positive for the cancer marker.


==Results==
==Results==
Line 97: Line 107:




<!--- Place two small Image J data images here. One showing the result of Water and the other showing the result of Calf Thymus DNA --->
<!--- Place two small [http://rsb.info.nih.gov/ij/ ImageJ] data images here. One showing the result of Water and the other showing the result of Calf Thymus DNA --->


These Images were taken using a HTC evo4G using the settings described under flourimeter measurements. <br>
These Images were taken using a [http://en.wikipedia.org/wiki/HTC_Evo_4G HTC Evo4G] using the settings described under flourimeter measurements. <br>


'''Water and SYBR green'''<br>
'''Water and SYBR green'''<br>
Line 121: Line 131:
| PCR: Positive Control || 8736864 || 6.472 || +
| PCR: Positive Control || 8736864 || 6.472 || +
|-
|-
| PCR: Patient 1 ID #####, rep 1 || 497871 || 0.369 || -
| PCR: Patient 1 ID 31464, rep 1 || 497871 || 0.369 || -
|-
|-
| PCR: Patient 1 ID #####, rep 2 || 197130 || 0.146 || -
| PCR: Patient 1 ID 31464, rep 2 || 197130 || 0.146 || -
|-
|-
| PCR: Patient 1 ID #####, rep 3 || 1126541 || 0.834 || -
| PCR: Patient 1 ID 31464, rep 3 || 1126541 || 0.834 || -
|-
|-
| PCR: Patient 2 ID #####, rep 1 || 4452498 || 3.298 || -
| PCR: Patient 2 ID 77979, rep 1 || 4452498 || 3.298 || -
|-
|-
| PCR: Patient 2 ID #####, rep 2 || 523003 || 0.387 || -
| PCR: Patient 2 ID 77979, rep 2 || 523003 || 0.387 || -
|-
|-
| PCR: Patient 2 ID #####, rep 3 || 6642729 || 4.921 || +
| PCR: Patient 2 ID 77979, rep 3 || 6642729 || 4.921 || +
|}
|}
<br>
<br>
Original Data Table : http://openwetware.org/wiki/Image:Fluorimeterexcel.jpg <br>
Original Data Table : http://openwetware.org/wiki/Image:Fluorimeterexcel.jpg <br>


KEY
'''KEY'''


* '''Integrated Density''' = Using the imageJ software, the image was split into its 'red', 'green' and 'blue' color components. This value represents the amount of 'green' light measured from the excitation through the blue LED light shining through the sample and subtracted from the background value, which was 'black' <!--- explain what "integrated density" means and how you did background subtraction to get this value --->  
* '''Integrated Density''' = Using the [http://rsb.info.nih.gov/ij/ ImageJ] software, the image was split into its 'red', 'green' and 'blue' color components. This value represents the amount of 'green' light measured from the excitation through the blue LED light shining through the sample and subtracted from the background value, which was 'black' <!--- explain what "integrated density" means and how you did background subtraction to get this value --->  
* '''DNA μg/mL''' = <!--- explain how you calculated this --->  
* '''DNA μg/mL''' = <!--- explain how you calculated this --->  
* '''Conclusion''' = The only replicate test that gave a positive value for cancer was patient two in their third replicate test, which yielded the highest DNA μg/mL. This indicated that the DNA reacted with the SYBR green to yield a positive result for screening for cancer. Using the data collected using the imageJ software, it is inconclusive to suggest that patient 2's first replicate data could be considered a positive for cancer considering the value obtained for the negative control.  
* '''Conclusion''' = Only the 3rd sample from patient 2 gave a positive result for cancer. This particular sample yielded a very high DNA μg/mL level. This indicated that the DNA reacted very well with the primers during PCR and created a lot of replicate DNA. This replicated DNA reacted with the SYBR green to yield a positive result for screening for cancer. All other samples were found to be below the negative control level, though some other samples from patient 2 were found to be high.
It is difficult to draw strong conclusions when all of the data is reviewed. The negative control read quite a high value for DNA presence meaning that some sort of error may have occurred. The negative control should have had very low levels of DNA present. To provide better results the experiment should be run again with an emphasis on achieving a lower level of DNA in the negative sample.


<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
|}
|}

Latest revision as of 13:57, 15 November 2012

BME 103 Fall 2012 Home
People
Lab Write-Up 1
Lab Write-Up 2
Lab Write-Up 3
Course Logistics For Instructors
Photos
Wiki Editing Help

OUR TEAM

Name: Emily Thompson
Research & Development Scientist
Name: Vivian Benjes
Experimental Protocol Planner/ Data Analyst
Name: Frances Marrett
Experimental Protocol Planner
Name: Chris Glass
Open PCR Machine Engineer
Name: Ryan Frantz
Open PCR Machine Engineer
[1]
Name: Cenric Nigbur
Ghost/ TBD

LAB 1 WRITE-UP

Initial Machine Testing

The Original Design
This is a PCR (polymerase chain reaction) machine (Open PCR 1 Jankowski and Perfetto). This machine is capable of replicating DNA through a series of temperature changes over timed cycles. It uses specialized primers to target specific gene sequences and is capable of amplifying singular stretches of DNA.


Experimenting With the Connections

When the PCB board was unplugged from the Open PCR circuit board, the machine's LED display ceased to function.

When the white wire that connects the Open PCR circuit board to the 16 tube PCR block was unplugged, the machine's LED display read -40 Celsius. This most likely indicated that the temperature could not be read on the device and that it was instead displaying a null value for the temperature.


Test Run

October 18,2012; The test program labeled "Simple Test", was performed on machine number 7 to ensure proper function of the Open PCR machine. It ran through two cycles at a full range of temperatures and tested all of the PCR machine's essential systems. No DNA was present for the test run. The test performed without any flaws and the machine proved to be fairly quick at reaching its desired temperature.




Protocols

Polymerase Chain Reaction

To amplify samples of DNA, the OpenPCR machine was used to perform a Polymerase Chain Reaction (PCR). This technique worked by cycling a mixture of DNA Template, Primers, Taq Polymerase, Magnesium Chloride, and dNTP's through three specific temperatures to create more copies of the desired sequence. After assembling the PCR mixture, the PCR machine was programmed to perform three stages. In the first stage, the samples went through one cycle at 95⁰C for 3 minutes. The purpose of this stage was to initially denature the DNA and allow the primers to act on the DNA. The second stage put the samples through 35 cycles of 95⁰C, 57⁰C, and 72⁰C each for 30 seconds. The purpose of the first part of the second stage is to break apart the hydrogen bonds between the base pairs, denaturing the DNA sequence into two separate strands. The purpose of the low temperature is to allow primers to bind. The purpose of the middle temperature is to create an environment for Taq Polymerase to assemble a new strand that is the desired product of the entire polymerase chain reaction. The last stage, stage three, puts the samples through one cycle of 72⁰C for 3 minutes. There is a final hold of 4⁰C that preserves the DNA. The samples were then taken out of the PCR machine. The target sequence had been amplified a million times and could now be analyzed with less sensitive equipment! To analyze the sequence, see the Fluorimeter section.


Fluorimeter Measurements

To analyze the DNA samples after they've been amplified, a smartphone with adjustable settings was used to take a photo of the samples.
These settings were used to accentuate the DNA smaples and a cradle was implemented to hold the phone in position for photographing:

- Exposure to highest setting
- ISO to 800+
- White balance to Automatic
- Saturation to highest setting
- Flash off if necessary
- Contrast to lowest setting


The Fluorimeter aparatus consists of a hydrophobic Teflon surface on a glass slide. There is an array of 3x10 glass wells on the surface to anchor drops in position for photographing. First, two drops of the cybergreen solution were placed on row 2, column 1&2 (Figure 1). With a sterile pipet two drops of amplified sample DNA were added to the cybergreen solution. It was important to place the DNA on top of the cybergreen in order to achieve the best results and to avoid contamination of the DNA samples. The picture was then photographed in the dark box with the door shut to eliminate excess background light. The next sample was prepared by sucking the liquid off the slide using a 'waste' pipet. The slide was then moved back by two columns for the next sample. This procedure was replicated for each of the patient samples and two slides were used in their entirety.

Picture and Analysis:

The pictures of each sample were analyzed using the "image j" software to process the images and analyze their content. The pictures, taken with the settings listed above, were upload to the "image j" software. The images were then separated into their composite colors, red, blue, and green. The green portion of the images were then analyzed using the software and its "INTDEN" was recorded.


Interpreting results:

The cybergreen soluiton allowed the amount of DNA in a sample to be determined by its "INTDEN". The cybergreen glowed green in the presence of DNA and while this glow was not visable to the naked eye, the smart phone in conjunction with "image j" was able to quantify the luminosity in terms of the "INTDEN". The brighter samples contained more DNA and had a higher "INTDEN" value. This indicated that the sample reacted with the primers better and was cancerous.

Research and Development

Specific Cancer Marker Detection - The Underlying Technology

Polymerase Chain Reaction, or PCR, is used to ampllify a specific segment of DNA, in this case the segment known to code for cancer. A primer, which is an artifically synthesized piece of complementary DNA, binds to the desired DNA segment, and the enzyme taq polymerase catalyzes the replication of the DNA strand using dNTPs (free bases). This is repeated over and over to produce many copies of the DNA. Once the copies are made, a fluorescent dye that only bonds to DNA double strands is added to the solution. If a solution that shows fluorescence by using a fluorimeter, then that DNA sample contains the cancer-associated sequence.

The single nucleotide polymorphism, or SNP, that is linked to cancer is rs17879961. The DNA base sequence associated with cancer is ACT, while the non-cancer sequence is ATT. PCR works to identify ACT from ATT because the primers, which are complementary to DNA strands containing cancer-positive ACT, will not bind to DNA containing ATT, and instead of DNA double strands, the solution will only contain single strands. The fluorescent dye will only bind to double strands and will identify those.



Adapted from: http://users.ugent.be/~avierstr/principles/pcr.html


Reliability through Bayes Law

Bayes Law expresses the probability that something is true. In this case, it relates to the probability that a person testing positive for cancer markers actually has cancer.


[math]\displaystyle{ P(A|X) = \frac{P(X|A) P(A)}{P(X)} = \frac{P(X|A) P(A)}{P(X|A) P(A) + P(X|notA) P(notA)} }[/math]

Bayes Law states that the probability of an event, A, given another event, X, is equal to the probability of X given A times the probability of A. This is then divided by the probability of X given A times the probability of A plus the probability of X given not A times the probability of not A. In the case of the cancer markers, events A and X might be the probability that a patient has cancer given that the patient tested positive for the cancer marker.

Results

These Images were taken using a HTC Evo4G using the settings described under flourimeter measurements.

Water and SYBR green



Water and SYBR green under split color conditions for green

SYBR green and Calf Thymus




Sample Integrated Density DNA μg/mL Conclusion
PCR: Negative Control 4498138 3.332 -
PCR: Positive Control 8736864 6.472 +
PCR: Patient 1 ID 31464, rep 1 497871 0.369 -
PCR: Patient 1 ID 31464, rep 2 197130 0.146 -
PCR: Patient 1 ID 31464, rep 3 1126541 0.834 -
PCR: Patient 2 ID 77979, rep 1 4452498 3.298 -
PCR: Patient 2 ID 77979, rep 2 523003 0.387 -
PCR: Patient 2 ID 77979, rep 3 6642729 4.921 +


Original Data Table : http://openwetware.org/wiki/Image:Fluorimeterexcel.jpg

KEY

  • Integrated Density = Using the ImageJ software, the image was split into its 'red', 'green' and 'blue' color components. This value represents the amount of 'green' light measured from the excitation through the blue LED light shining through the sample and subtracted from the background value, which was 'black'
  • DNA μg/mL =
  • Conclusion = Only the 3rd sample from patient 2 gave a positive result for cancer. This particular sample yielded a very high DNA μg/mL level. This indicated that the DNA reacted very well with the primers during PCR and created a lot of replicate DNA. This replicated DNA reacted with the SYBR green to yield a positive result for screening for cancer. All other samples were found to be below the negative control level, though some other samples from patient 2 were found to be high.

It is difficult to draw strong conclusions when all of the data is reviewed. The negative control read quite a high value for DNA presence meaning that some sort of error may have occurred. The negative control should have had very low levels of DNA present. To provide better results the experiment should be run again with an emphasis on achieving a lower level of DNA in the negative sample.