BioMicroCenter:Caliper LabChip GX: Difference between revisions
Manlin Luo (talk | contribs) (New page: {{BioMicroCenter}} The Caliper LabChip GX is the most accurate and advanced nucleic acid separations system. The GX suite of instruments utilizes Caliper’s innovative microfluidics tec...) |
Manlin Luo (talk | contribs) No edit summary |
||
Line 7: | Line 7: | ||
*Flexible with 96 and 384 well compatibility | *Flexible with 96 and 384 well compatibility | ||
*Comprehensive and quantitative analysis with LabChip GX software | *Comprehensive and quantitative analysis with LabChip GX software | ||
=== [[BioMicroCenter:Caliper_INFO | Available Analyses]] === | |||
'''HiSens DNA ''' | |||
Sensitivity: | |||
Standard Workflow | |||
*5 pg/μL per fragment | |||
*100 pg/μL for smears | |||
Limited Sample Workflow | |||
*10 pg/μL per fragment | |||
*200 pg/μL for smears | |||
'''Total RNA ''' | |||
RNA metrics such as peak heights, peak areas, and concentration are used to determine an RQS (RNA Quality Score) number for each sample. The Caliper RQS is a calculated score that rates the quality of RNA samples. The RQS has been validated to correlate well with Agilent’s RIN (RNA Integrity Number) and follows the same 0-10 scale rating. Results comparing RIN to RQS for the same samples run on both LabChip GX and Agilent’s Bioanalyzer 2100 typically show <10% deviation. |
Revision as of 13:48, 28 February 2011
HOME -- | SEQUENCING -- | LIBRARY PREP -- | HIGH-THROUGHPUT -- | COMPUTING -- | OTHER TECHNOLOGY |
The Caliper LabChip GX is the most accurate and advanced nucleic acid separations system. The GX suite of instruments utilizes Caliper’s innovative microfluidics technology to perform reproducible, high-resolution, eletrophoretic separations.
- Complete assessment of RNA quality for better gene expression data
- Exact sizing and quantitation of DNA fragments
- Extreme accuracy with resolution down to 5 bp and sensitivity of 0.1ng/ul
- Flexible with 96 and 384 well compatibility
- Comprehensive and quantitative analysis with LabChip GX software
Available Analyses
HiSens DNA
Sensitivity:
Standard Workflow
- 5 pg/μL per fragment
- 100 pg/μL for smears
Limited Sample Workflow
- 10 pg/μL per fragment
- 200 pg/μL for smears
Total RNA
RNA metrics such as peak heights, peak areas, and concentration are used to determine an RQS (RNA Quality Score) number for each sample. The Caliper RQS is a calculated score that rates the quality of RNA samples. The RQS has been validated to correlate well with Agilent’s RIN (RNA Integrity Number) and follows the same 0-10 scale rating. Results comparing RIN to RQS for the same samples run on both LabChip GX and Agilent’s Bioanalyzer 2100 typically show <10% deviation.