DIYbio/BOSSlab/Notebook/2011/05/15
From OpenWetWare
(Difference between revisions)
(Autocreate 2011/05/15 Entry for DIYbio/BOSSlab/Notebook) |
(→Entry title) |
||
| Line 6: | Line 6: | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
| - | == | + | == Preflight == |
| - | * | + | what's our goal: |
| + | transformation of Invivogen lyocomp cells w/ BBa_J04450 on card (circa 2008). | ||
| + | |||
| + | === Materials === | ||
| + | * lyocomp E. coli 116, (k12 derived?), non-pathogenic. http://www.invivogen.com/family.php?ID=189 | ||
| + | * BBa_J04450 plasmid-on-card. Ampicillin resistant, based on pSB1A4. http://partsregistry.org/Part:pSB4A1 | ||
| + | * 1000x stock of ampicillin | ||
| + | * LB-agar (1 L) | ||
| + | * SOC, 1.8 mL | ||
| + | * pressure sterilizer, burner, propane | ||
| + | * ice, water, 50g scale, fridge, freezer, incubator, p200, p1000, tips, gloves, bleach | ||
| + | |||
| + | |||
| + | === what are the risks to us === | ||
| + | * fire hazard: pressure sterilizer + propane burner | ||
| + | * chemical hazard: bleach | ||
| + | * chemical hazard: concentrated ampicillin | ||
| + | * experimental hazard: lab-grade E. coli contamination on bench surfaces | ||
| + | * temperature hazard: molten LB-agar | ||
| + | |||
| + | === what waste are we gonna generate === | ||
| + | * bleach + LB-agar (solid) | ||
| + | * combusted propane gas | ||
| + | * water | ||
| + | * tips used to transfer & mix transformed E. coli (bleached) | ||
| + | |||
| + | === mitigation of community risks === | ||
| + | * chemical hazards: propane leak in air | ||
| + | ** only use burner outdoors on concrete | ||
| + | * e. coli on tips | ||
| + | ** dispose of pipet tips into bleach solution, bag & throw away. | ||
| + | |||
| + | |||
| + | == Protocol == | ||
| + | based on http://www.invivogen.com/PDF/LyoComp_GT116_TDS.pdf | ||
| + | |||
| + | # Thaw competent cells (Lyocomp E. coli 116) & rehydration solution on ice. | ||
| + | # Chill 1.5 mL centrifuge tubes on ice. | ||
| + | # Rehydrate lyophilized cells with 0.5 mL "rehydration solution" | ||
| + | # Let cells rehydrate for 30 min on ice | ||
| + | # Add "DNA chads" from biobrick card to 1.5 mL centrifuge tubes | ||
| + | # dispense 250 mL of rehydrated lyocomp cells to each 1.5 mL centrifuge tube. Mix. | ||
| + | # Incubate 30 min on ice. | ||
| + | # During this time pre-heat water bath to 42°C (don’t use heating block). | ||
| + | # Incubate samples at 42°C in the water bath for exactly 30s. | ||
| + | # Immediately chill samples on ice for 2 minutes. | ||
| + | # Add 900 uL of room temperature SOC to each tube. | ||
| + | # Incubate at 37 C for 90 min, shaking at 250 RPM | ||
| + | # Spread 100 uL of transformed bacteria on LB-Amp plates. | ||
| + | # Incubate plates at 37°C for 18 h. | ||
| + | |||
| + | |||
| + | |||
| + | == Notes == | ||
| + | * p1000 tips don't fit in lyocomp vial. Used p200 tips. Only removed 400 uL (200 uL to each 1.5 mL tube) of rehydrated e. coli from the vial. | ||
| + | * unsure of concentration and age of frozen Amp stock. Assuming 1000x. Poured two LB plates without the amp. Added 100 uL transformant to each. | ||
| + | * distributed 100 uL transformant to two LB-Amp plates. | ||
| + | * incubating one 1.5 mL tube with remaining transformant (900 uL) at 37 C. no shaking. | ||
| + | * storing the other 1.5 mL tube with remaining transformant (900 uL) at 4 C. | ||
| + | * incubation started at xxx PM 5/15/2011 | ||
Revision as of 22:17, 15 May 2011
Main project page Previous entry
| |
Preflightwhat's our goal: transformation of Invivogen lyocomp cells w/ BBa_J04450 on card (circa 2008). Materials
what are the risks to us
what waste are we gonna generate
mitigation of community risks
Protocolbased on http://www.invivogen.com/PDF/LyoComp_GT116_TDS.pdf