== AHL Signal Extraction == | |||
In a large test tube containing the sample you wish to test: | |||
# Add 5mL of ethyl acetate and vortex on high for 30seconds | |||
# Let the sample sit for 10 minutes to allow the two phases to separate out. | |||
# After the 10 minute rest, pipette off the clear acetate layer only being careful to not draw up any of the bottom cell debris layer. | |||
# Deposit the clear acetate layer in a 10mL glass tube with a sealable air tight cap. | |||
# Repeat steps 1-4 and add acetate supernatant to collection tube from step 4. | |||
# Place acetate filled tubes into N2 evaporator until all acetate has evaporated off. (keep on low level to prevent splashing) | |||
# Suspend dried signal in 100uL of ethyl acetate, screw sealable cap on tightly, wrap in parafilm and place in -20 freezer. | |||
Revision as of 14:26, 22 January 2014
AHL Signal Extraction
In a large test tube containing the sample you wish to test:
- Add 5mL of ethyl acetate and vortex on high for 30seconds
- Let the sample sit for 10 minutes to allow the two phases to separate out.
- After the 10 minute rest, pipette off the clear acetate layer only being careful to not draw up any of the bottom cell debris layer.
- Deposit the clear acetate layer in a 10mL glass tube with a sealable air tight cap.
- Repeat steps 1-4 and add acetate supernatant to collection tube from step 4.
- Place acetate filled tubes into N2 evaporator until all acetate has evaporated off. (keep on low level to prevent splashing)
- Suspend dried signal in 100uL of ethyl acetate, screw sealable cap on tightly, wrap in parafilm and place in -20 freezer.