AHL Signal Extraction

In a large test tube containing the sample you wish to test:

  • Add 5mL of ethyl acetate and vortex on high for 30seconds
  • Let the sample sit for 10 minutes to allow the two phases to separate out.
  • After the the 10 minute rest, pipette off the clear acetate layer only. Be careful to not draw up any of the bottom cell debris layer.
  • Deposit the clear acetate layer in a 10mL glass tube with a sealable air tight cap.
  • Repeat steps 1-4 and add acetate supernatant to tube from first cycle.
  • Place acetate filled tubes into N2 evaporator on medium until all acetate has evaporated off.