Endy:Library-based construction/Inverter library protocol: Difference between revisions
From OpenWetWare
Jump to navigationJump to search
Line 18: | Line 18: | ||
==Transform into electrocompetent CW2553/pJat8== | ==Transform into electrocompetent CW2553/pJat8== | ||
=== | ===Controls=== | ||
*(+): [http://invitrogen.com/search/index.cfm?fuseaction=google.search&searchTerm=pUC18&num=10&category=Vectors pUC18] (Amp resistance) ([[Endy:Standard_transformation_positive_control|efficiencies]]) | *(+): [http://invitrogen.com/search/index.cfm?fuseaction=google.search&searchTerm=pUC18&num=10&category=Vectors pUC18] (Amp resistance) ([[Endy:Standard_transformation_positive_control|efficiencies]]) | ||
*(-): cells only | *(-): cells only | ||
==Procedure== | ==Procedure== | ||
#Keep 2mm cuvettes on ice | #Keep 2mm cuvettes on ice |
Revision as of 09:01, 24 July 2006
We should be fleshing this out as we work through it a few times
Generate inverter library via mutagenic PCR
- 50 ul PCR reaction using Stratagene's GeneMorph® II Random Mutagenesis kit
- PCR cleanup and elute with 30 ul
Digest the library and ligate into SP1.0
- Perform a 50 ul restriction digest using all of the PCR reaction
- Separate the insert out on a gel and perform gel extraction
- Elute the entire reaction into a single 30 ul volume (reuse on multiple columns if necessary)
- Perform a 40-ul ligation:
- 4 ul 10X T4 DNA ligase buffer
- All of the digest
- Can also save some of the ligation and use less, probably don't need this much
- 1 ul of the cut SP1.0 vector
- 2 ul T4 DNA ligase
- H20 to 40 ul
Transform into electrocompetent CW2553/pJat8
Controls
- (+): pUC18 (Amp resistance) (efficiencies)
- (-): cells only
Procedure
- Keep 2mm cuvettes on ice
- Dialyze ligation product ~20 min
- Thaw electrocompotent cells (40 ul per tube) on ice
- Add 1 ml of SOB (from media room) to 12x75mm culture tube(s)
- Quickly spin down the thawed cells and add 3 ul (more, less?) of ligation product to the cells
- Keep on ice as much as possible
- Swirl with pipette tip to mix, pipetting is bad (heat, shear?)
- Add cell/DNA mix to the cuvettes in the center channel
- On the electroporation machine's menu, go to 4) pre-set protocols; 1) bacterial; 2) E.Coli-2mm, 2.5kV
- Should end up on a screen that lists the voltage and other parameters
- Should have a blinking 'P' in the corner of the screen
- Tap the cuvette on the table to settle cells to the bottom of the chamber, wipe the metal with a kim wipe and place in electroporation machine
- Press pulse button, wait, and check for a exponential decay graph with ~1800 volts applied and a time of ~4s
- If the screen goes back to the main menu, it worked
- If you hear a cracking noise/loud pop, sample arced, cells died, try again
- Quickly add the 1 ml of SOB from the culture tube and pipette up and down to get cells out of the chamber, then pipette everything back into the culture tube
- Grow for one hour without antibiotic (1ml)
- plate a portion (50 ul? more, less?) on selective media in order to determine the library size
- plate a portion (1/1e6? 1e7?) on non-selective media in order to determine the number of surviving cells following electroporation
- Move the rest of the culture into a higher volume (10ml?) of selective media
Rest of procedure
- Store 5 glycerols of the libary from the overnight culture
- Spin down cells and switch to M9 media
- Measure OD to determine how many cells to add to your experimental cultures
- To be safe, take at least 10 times the library size (calculated from plates)
- Start experimental cultures with no induction and high induction
- Be sure to make a high enough dilution to allow for at least 9 doublings without going into stationary (OD600 < ~1)
- Grow overnight (rough doubling time is ~1.5-2 hrs)
- Sort cells with LOW in/HIGH out and HIGH in/LOW out into sub-libraries
- Be sure to also collect analytical samples of the populations after sorting, so that we have data of what the libraries looked like.
- Grow up the sub-libraries under the reverse condition (and the same condition)
- The reason for growing under the same conditions is to see how effective the sorting was (control, basically).
- Conduct second round of sorting to create sub-libraries that we're tested under both HIGH input and LOW input conditions
- Grow up library and store 5 glycerols, as well as plate to get individual mutants
- Test individual mutants, if necesary can repeat the rounds of screening to tighten up the library