* Insert content here...
+
Spun overnight cultures of GFP-Senders at 13.1g for 10 minutes in 2mL tubes in benchtop centrifuge. Filtered using Fuqing's 0.45μm sterile filters and syringes. Made 5mL of 1% LuxI media. 5mL of LB+amp and 50ul LuxI sender.
-
 
+
<br>
 +
Set up microfluidics with David Menn. LuxI inducing LuxR-GFP at 1%.
 +
<br>
 +
Made dilutions of filtered sender media. Wanted to make sure each concentration has the same ratio of spent media to fresh media. Made 1800ul. 300ul for 3 replicates of each dilution. 1500ul for flow cytometry. Can take some off the top at multiple time points.
 +
<br>
 +
{| {{table}}
 +
| align="center" style="background:#f0f0f0;"|'''%media'''
 +
| align="center" style="background:#f0f0f0;"|'''Total media'''
 +
| align="center" style="background:#f0f0f0;"|'''ul sender'''
 +
| align="center" style="background:#f0f0f0;"|'''ul LB media'''
 +
| align="center" style="background:#f0f0f0;"|'''ul spent ctrl media'''
 +
|-
 +
| 10||1800||180||1620||0
 +
|-
 +
| 5||1800||90||1620||90
 +
|-
 +
| 2.5||1800||45||1620||135
 +
|-
 +
| 1.25||1800||22.5||1620||157.5
 +
|-
 +
| 0.625||1800||11.25||1620||168.75
 +
|-
 +
| 0.3125||1800||5.625||1620||174.375
 +
|}
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Current revision

Project name Main project page
Previous entry      Next entry

02/26/2014

Spun overnight cultures of GFP-Senders at 13.1g for 10 minutes in 2mL tubes in benchtop centrifuge. Filtered using Fuqing's 0.45μm sterile filters and syringes. Made 5mL of 1% LuxI media. 5mL of LB+amp and 50ul LuxI sender.
Set up microfluidics with David Menn. LuxI inducing LuxR-GFP at 1%.
Made dilutions of filtered sender media. Wanted to make sure each concentration has the same ratio of spent media to fresh media. Made 1800ul. 300ul for 3 replicates of each dilution. 1500ul for flow cytometry. Can take some off the top at multiple time points.

%media Total media ul sender ul LB media ul spent ctrl media
10180018016200
5180090162090
2.51800451620135
1.25180022.51620157.5
0.625180011.251620168.75
0.312518005.6251620174.375