'''Overview of set-up'''
'''Overview of set-up'''
-
Tower+Monitor uses “Optacon Stimulator” software to provide input to Optacon Interface (the rectangular box with the TRS connectors/jacks).
+
*Tower+Monitor uses “Optacon Stimulator” software to provide input to Optacon Interface (the rectangular box with the TRS connectors/jacks).
-
The Optacon Interface uses input from Opticon Stimulator to drive the optacon
+
*The Optacon Interface uses input from Opticon Stimulator to drive the optacon
-
Powerlab box reads from Optacon Interface
+
*Powerlab box reads from Optacon Interface
-
Response buttons are connected to the Powerlab box
+
*Response buttons are connected to the Powerlab box
-
Laptop with Labchart collects the output from Powerlab box (button presses and signal from pins)
+
*Laptop with Labchart collects the output from Powerlab box (button presses and signal from pins)
-
Switching on the system
+
'''Switching on the system'''
-
Turn on the computers
+
*Turn on the computers
-
Turn on Powerlab box (switch at back next to grey cord)  
+
*Turn on Powerlab box (switch at back next to grey cord)  
-
Turn on Optacon Interface (switch on top of box where it says Power)
+
*Turn on Optacon Interface (switch on top of box where it says Power)
-
Optacon should be the last thing you switch on
+
*Optacon should be the last thing you switch on
-
Switching off the system
+
'''Switching off the system'''
-
Optacon should be the first thing you switch off
+
*Optacon should be the first thing you switch off
-
Then switch off the Optacon Interface + Powerlab box
+
*Then switch off the Optacon Interface + Powerlab box
-
Then switch off computers
+
*Then switch off computers
-
Input to Optacon interface
+
'''Input to Optacon interface'''
-
The tower+monitor provides input to the optacon interface
+
*The tower+monitor provides input to the optacon interface
-
Open Optacon Stimulator
+
*Open Optacon Stimulator
-
Create New or Open
+
*Create New or Open
-
Uses .txt files – can make these in excel etc.
+
*Uses .txt files – can make these in excel etc.
-
Array (frames) is the input
+
*Array (frames) is the input
-
Dwell time – how long it stays on that frame  
+
*Dwell time – how long it stays on that frame  
-
Pins have fixed vibration rate  
+
*Pins have fixed vibration rate  
-
Single protraction/retraction is 4.35ms for ~230Hz vibration
+
** Single protraction/retraction is 4.35ms for ~230Hz vibration
-
Dwell time specifies how long the pins vibrate in the arrangement of that frame
+
*Dwell time specifies how long the pins vibrate in the arrangement of that frame
-
Note: Should take into account 4.35ms “frame duration”
+
** Note: Should take into account 4.35ms “frame duration”
-
e.g. if you put 5ms, It will do 2 protractions/frames, actually taking 8.7ms
+
***e.g. if you put 5ms, It will do 2 protractions/frames, actually taking 8.7ms
-
OR Click on cells to manually change them
+
*OR Click on cells to manually change them
-
In array/frames for input: specify number of Blocks and Stimuli
+
*In array/frames for input: specify number of Blocks and Stimuli
-
Blocks are like the Folder
+
*Blocks are like the Folder
-
Stimuli are within blocks  
+
**Stimuli are within blocks  
-
Can repeat blocks or stimuli independently  
+
*Can repeat blocks or stimuli independently  
-
In the input window for the pins  
+
*In the input window for the pins  
-
ANIMATE – can visualize how the pins are moving
+
**ANIMATE – can visualize how the pins are moving
-
Switch off animate when running experiment
+
**Switch off animate when running experiment
-
Can cause lag if it is switched on
+
*** Can cause lag if it is switched on
-
LOOP – will repeat whole sequence including blocks, stimuli – toggle on/off
+
**LOOP – will repeat whole sequence including blocks, stimuli – toggle on/off
-
First 5 seconds of task should be empty –
+
*First 5 seconds of task should be empty –
-
Might be vibrations due to noise etc, so have first 5 seconds empty to ensure experiment starts off clean
+
**Might be vibrations due to noise etc, so have first 5 seconds empty to ensure experiment starts off clean
-
Powerlab box
+
*Powerlab box
-
Can choose which pins the Powerlab box records from
+
**Can choose which pins the Powerlab box records from
-
Data Collection
+
"Data Collection"
-
Laptop has Labchart on it
+
*Laptop has Labchart on it
-
Uses this for data collection
+
**Uses this for data collection
Starting Labchart:
Starting Labchart:
-
Labchart shortcut is on the desktop
+
*Labchart shortcut is on the desktop
-
When labchart loads it will seach for optacon interface
+
*When labchart loads it will seach for optacon interface
-
If optacon interface is powered off you can still load labchart
+
**If optacon interface is powered off you can still load labchart
-
e.g. if you want to look at data
+
***e.g. if you want to look at data
-
If you want to use it with the optacon interface make sure interface is on first
+
**If you want to use it with the optacon interface make sure interface is on first
-
To use settings that have been made for use with optacon:
+
*To use settings that have been made for use with optacon:
-
Open a template (e.g ‘example’)
+
**Open a template (e.g ‘example’)
-
Then: File – new – will ask if want to use settings based on other worksheet – click ‘yes’
+
***Then: File – new – will ask if want to use settings based on other worksheet – click ‘yes’
Testing if everything is connected properly
Testing if everything is connected properly
-
Make a file that shows the button presses and the pins you are interested in recording from
+
*Make a file that shows the button presses and the pins you are interested in recording from
-
Run and check if button presses and pin recordings correspond to the correct channel
+
*Run and check if button presses and pin recordings correspond to the correct channel
-
e.g. Pin input test – test everything is plugged in properly
+
**e.g. Pin input test – test everything is plugged in properly
Recording:
Recording:
-
Press START button in the bottom right hand corner to start recording
+
*Press START button in the bottom right hand corner to start recording
-
Top 3 channels shows input – i.e. response from pressing buttons
+
*Top 3 channels shows input – i.e. response from pressing buttons
-
Bottom 3 channels records from pins
+
*Bottom 3 channels records from pins
-
Can toggle MONITOR to the left of start button – it will monitor responses/input but doesn’t record
+
*Can toggle MONITOR to the left of start button – it will monitor responses/input but doesn’t record
-
Make sure it is off when you want to collect data
+
** Make sure it is off when you want to collect data
-
Monitor Off / Recording– Not showing red X
+
*** Monitor Off / Recording– Not showing red X
-
Monitor On / Not Recording – Showing red X
+
*** Monitor On / Not Recording – Showing red X
-
Can also set up new channels to calculate things from the other channels
+
*Can also set up new channels to calculate things from the other channels
Saving:
Saving:
-
Save raw data as an .adicht file before doing anything  
+
*Save raw data as an .adicht file before doing anything  
-
Can select data points – ‘save as’ data file
+
*Can select data points – ‘save as’ data file
For stats:
For stats:
-
File – export – labchart txt file
+
*File – export – labchart txt file
-
Samples at 10k a second – can downsample it for smaller file size
+
*Samples at 10k a second – can downsample it for smaller file size - this may reduce precision of optacon pins because they are very fast (so find a suitable sampling rate for your purposes)
-
this may reduce precision of optacon pins because they are very fast  
+
-
(so find a suitable sampling rate for your purposes)
+
Notes for running participants
Notes for running participants
-
Instruct participants that they do not need to press hard on buttons
+
*Instruct participants that they do not need to press hard on buttons
-
Feels like it isn’t registering but it is
+
**Feels like it isn’t registering but it is
-
Use scales to measure pressure on fingers
+
*Use scales to measure pressure on fingers
-
Keep this constant over conditions and participants  
+
**Keep this constant over conditions and participants  
-
 
+
**If pressure is too high – will dampen the vibrations – should be gently touching
-
If pressure is too high – will dampen the vibrations – should be gently touching
+
Misc notes:
Misc notes:
-
Pull out blue cord at back of optacon to use the visual input part of the optacon  
+
*Pull out blue cord at back of optacon to use the visual input part of the optacon  
-
Switch at back – INVERT – black on white or white on black
+
*Switch at back – INVERT – black on white or white on black
-
Make sure optacon is not resting on the array – can damage the pins
+
*Make sure optacon is not resting on the array – can damage the pins
-
ALWAYS BE CAREFUL – it is a fragile piece of equipment we can’t easily replacea
+
*'''ALWAYS BE CAREFUL – it is a fragile piece of equipment we can’t easily replace'''
--[[User:Elizabeth Nguyen|Elizabeth Nguyen]] 01:47, 13 July 2012 (EDT)
--[[User:Elizabeth Nguyen|Elizabeth Nguyen]] 01:47, 13 July 2012 (EDT)

Revision as of 02:02, 13 July 2012

Members

Alex Holcombe
Sarah McIntyre
Fahed Jbarah
• Shih-Yu Lo
• Patrick Goodbourn
Lizzy Nguyen
Alumni


Technical

Skills Checklist
Python Programming
Psychopy/VisionEgg Installation Notes
R analysis,plot,stats
Statistics
Buttonbox
Verifying timing
Programming Cheat Sheets



USING THE OPTACON

Instructions for using the Optacon setup (draft)


Overview of set-up

  • Tower+Monitor uses “Optacon Stimulator” software to provide input to Optacon Interface (the rectangular box with the TRS connectors/jacks).
  • The Optacon Interface uses input from Opticon Stimulator to drive the optacon
  • Powerlab box reads from Optacon Interface
  • Response buttons are connected to the Powerlab box
  • Laptop with Labchart collects the output from Powerlab box (button presses and signal from pins)

Switching on the system

  • Turn on the computers
  • Turn on Powerlab box (switch at back next to grey cord)
  • Turn on Optacon Interface (switch on top of box where it says Power)
  • Optacon should be the last thing you switch on

Switching off the system

  • Optacon should be the first thing you switch off
  • Then switch off the Optacon Interface + Powerlab box
  • Then switch off computers

Input to Optacon interface

  • The tower+monitor provides input to the optacon interface
  • Open Optacon Stimulator
  • Create New or Open
  • Uses .txt files – can make these in excel etc.
  • Array (frames) is the input
  • Dwell time – how long it stays on that frame
  • Pins have fixed vibration rate
    • Single protraction/retraction is 4.35ms for ~230Hz vibration
  • Dwell time specifies how long the pins vibrate in the arrangement of that frame
    • Note: Should take into account 4.35ms “frame duration”
      • e.g. if you put 5ms, It will do 2 protractions/frames, actually taking 8.7ms
  • OR Click on cells to manually change them
  • In array/frames for input: specify number of Blocks and Stimuli
  • Blocks are like the Folder
    • Stimuli are within blocks
  • Can repeat blocks or stimuli independently
  • In the input window for the pins

**ANIMATE – can visualize how the pins are moving **Switch off animate when running experiment *** Can cause lag if it is switched on **LOOP – will repeat whole sequence including blocks, stimuli – toggle on/off


  • First 5 seconds of task should be empty –
    • Might be vibrations due to noise etc, so have first 5 seconds empty to ensure experiment starts off clean
  • Powerlab box
    • Can choose which pins the Powerlab box records from

"Data Collection"

  • Laptop has Labchart on it
    • Uses this for data collection

Starting Labchart:

  • Labchart shortcut is on the desktop
  • When labchart loads it will seach for optacon interface

**If optacon interface is powered off you can still load labchart ***e.g. if you want to look at data **If you want to use it with the optacon interface make sure interface is on first

  • To use settings that have been made for use with optacon:
    • Open a template (e.g ‘example’)
      • Then: File – new – will ask if want to use settings based on other worksheet – click ‘yes’

Testing if everything is connected properly

  • Make a file that shows the button presses and the pins you are interested in recording from
  • Run and check if button presses and pin recordings correspond to the correct channel
    • e.g. Pin input test – test everything is plugged in properly


Recording:

  • Press START button in the bottom right hand corner to start recording
  • Top 3 channels shows input – i.e. response from pressing buttons
  • Bottom 3 channels records from pins
  • Can toggle MONITOR to the left of start button – it will monitor responses/input but doesn’t record
    • Make sure it is off when you want to collect data
      • Monitor Off / Recording– Not showing red X
      • Monitor On / Not Recording – Showing red X
  • Can also set up new channels to calculate things from the other channels

Saving:

  • Save raw data as an .adicht file before doing anything
  • Can select data points – ‘save as’ data file

For stats:

  • File – export – labchart txt file
  • Samples at 10k a second – can downsample it for smaller file size - this may reduce precision of optacon pins because they are very fast (so find a suitable sampling rate for your purposes)

Notes for running participants

  • Instruct participants that they do not need to press hard on buttons
    • Feels like it isn’t registering but it is
  • Use scales to measure pressure on fingers
    • Keep this constant over conditions and participants
    • If pressure is too high – will dampen the vibrations – should be gently touching

Misc notes:

  • Pull out blue cord at back of optacon to use the visual input part of the optacon
  • Switch at back – INVERT – black on white or white on black
  • Make sure optacon is not resting on the array – can damage the pins
  • ALWAYS BE CAREFUL – it is a fragile piece of equipment we can’t easily replace


--Elizabeth Nguyen 01:47, 13 July 2012 (EDT)