* Our team is working to create a biosensor that detects the presence of a toxin via the change in resistance of the bacterial solution.
* Our team is working to create a biosensor that detects the presence of a toxin via the change in resistance of the bacterial solution.
 +
 +
Testing apparatus with NaCl at different concentrations
 +
 +
• 3 plates with 0.05M NaCl (0.02922g in 10mL)
 +
 +
• 3 plates with 0.005M NaCl (0.02922g in 100mL)
 +
 +
• 3 plates with 0.001M NaCl (0.01461g in 250mL)
 +
 +
dilute to each concentration then put 10 mL of each solution in respective plates
 +
 +
Control: distilled water
 +
 +
Results:
 +
 +
Control: 4.108Mohm, 2.517Mohm, 2.934Mohm
 +
 +
0.001M NaCl: 393.7 kohm, 265.5kohm, 579.6kohm
 +
 +
0.005M NaCl: 264.9kohm, 266kohm, 326.1kohm
 +
 +
0.05M NaCl: 233.5kohm, 46.69kohm, 97.1kohm
 +
 +
control 0.001M NaCl 0.005M NaCl 0.05M NaCl
 +
 +
3.186MΩ 0.4129MΩ 0.2857MΩ 0.1258MΩ
 +
 +
0.001M NaCl: 2.7731MΩ change
 +
 +
0.005M NaCl: 2.9003MΩ change
 +
 +
0.05M NaCl: 3.0602MΩ change
 +
 +
• Our wires were not long enough to touch the solution in the plates—next time don’t tape wires in place until right before experiment begins
 +
 +
• WE NEED A COMPUTER BASED VOLTMETER
 +
 +
 +
Questions for Dan Ludwig (Meeting Friday 3:00pm)
 +
 +
Should touching the plastic significantly change the resistance?
 +
 +
What if distance changes slightly?
 +
 +
All considerations of our apparatus
 +
 +
Any suggestions for a real-time, computer based voltmeter?
 +
 +
Tomorrow: get plates from Harvard lab!
 +
 +
Create glycerol stocks of the plasmids
 +

Current revision

iGEM Project name 1 Main project page
Previous entry      Next entry

Team Resistance

  • Our team is working to create a biosensor that detects the presence of a toxin via the change in resistance of the bacterial solution.

Testing apparatus with NaCl at different concentrations

• 3 plates with 0.05M NaCl (0.02922g in 10mL)

• 3 plates with 0.005M NaCl (0.02922g in 100mL)

• 3 plates with 0.001M NaCl (0.01461g in 250mL)

dilute to each concentration then put 10 mL of each solution in respective plates

Control: distilled water

Results:

Control: 4.108Mohm, 2.517Mohm, 2.934Mohm

0.001M NaCl: 393.7 kohm, 265.5kohm, 579.6kohm

0.005M NaCl: 264.9kohm, 266kohm, 326.1kohm

0.05M NaCl: 233.5kohm, 46.69kohm, 97.1kohm

control 0.001M NaCl 0.005M NaCl 0.05M NaCl

3.186MΩ 0.4129MΩ 0.2857MΩ 0.1258MΩ

0.001M NaCl: 2.7731MΩ change

0.005M NaCl: 2.9003MΩ change

0.05M NaCl: 3.0602MΩ change

• Our wires were not long enough to touch the solution in the plates—next time don’t tape wires in place until right before experiment begins

• WE NEED A COMPUTER BASED VOLTMETER


Questions for Dan Ludwig (Meeting Friday 3:00pm)

Should touching the plastic significantly change the resistance?

What if distance changes slightly?

All considerations of our apparatus

Any suggestions for a real-time, computer based voltmeter?

Tomorrow: get plates from Harvard lab!

Create glycerol stocks of the plasmids