Goals for this week
- Talk to Helen, Pete, etc. =)
- Work on growing anaerobically, the electric current, and everything together?
- Check that Shewie is growing by putting it with media, bubbling N2 gas.
Monday: June 30, 2008
Goals
- autopsy/cleaning
- LML current test
- anaerobic burnicite test
- research/buy O2 test kit
- Questions to Peter/Helen/Orianna
Results from autopsy
- membrane is pink but looks perfectly intact
- regular epoxy on cathode looks different
- dull grey color rather than silver black
- feels like rubber, starting to rub off
- fluffy white stuff in the cathode chamber where no bacteria was present
- white/clear gluey stuff growing in cathode chamber
- looked at under microscope -> looks like bacteria!
Lab
MFC Design changes
- remade anode and cathode without using epoxy:
- anode: titanium wire is wrapped around carbon felt
- cathode: titanium wire weaves around Pt covered carbon cloth
Anaerobic burnicide test
- see Tuesday for results
LML Current test
- baseline current of 1 microampere
- injected Shewie into anode side
- did not observe any noticeable change in current
- will try again with a higher density of Shewie
**Note: There was an initial hook-up error in cables**
Tuesday: July 1, 2008
Lab
Results from Anaerobic Burnicide test
Done at pH 7.3
PHOTO WILL GO HERE
- Anaerobic chamber with Shewie: went from brown to light yellow
- Anaerobic chamber without Shewie: stayed a clear brown
- Aerobic chamber with Shewie: turned slightly lighter but noticeably darker than anaerobic chamber with Shewie
Conclusion: LML media should be fine for anaerobic growth in Shewie.
Experiment: Plated anaerobic Shewie and aerobic Shewie from chambers to grow colonies.
Resazurin test
4 vials
- LML, open, 1 mL of 0.8 mM resazurin
- LML, open, 1 mL of 0.8 mM resazurin, 1 mL Shewie
- LML, closed, 1 mL of 0.8 mM resazurin, 1 mL Shewie
- LB, closed, 1 mL of 0.8 mM resazurin, 1 mL Shewie
Results
- Within a minute, vial with LB changed color
- Half an hour to an hour later, the closed vial with LML and Shewie also changed color
Photos?
Conclusions
- Resazurin works as an indicator of O2
- Worth trying LB and lactate (neutralized with NaOH) as the media since it appears to work much faster
Note: Resazurin will turn from clear to pink when exposed to oxygen again, but not to blue (first reduction step is irreversible)
Current Test
Paramaters Media: LB + 20 mM lactate at a pH of 6.96 (neutralized with NaOH), in both chambers Shewie: 10 mL of Shewie spun down, resuspended in 1 mL of LML Resistance: 400 ohms
Results
- Observed current increase approximately 7 minutes after Shewie were inserted
- Leveled off at approximately 34 microamps