The system performance here revolves most importantly around AHL sensitivity; however, the effect on, maximal output of fluorescent reporter protein and/or response time is, likewise, of great importance.
The system performance here revolves most importantly around AHL sensitivity; however, the effect on, maximal output of fluorescent reporter protein and/or response time is, likewise, of great importance.


Our approach involves a proposal of two simple constructs, varying with respect to the manner in which LuxR is introduced into the system:
Our approach, involves the proposal of two simple constructs, varying with respect to the manner in which LuxR is introduced into the system:
*Construct 1 - represented by T9002, incorporates constitutive expression of LuxR by pTET.
*Construct 1 - represented by T9002, incorporates constitutive expression of LuxR by pTET.
*Construct 2 - simpler in nature, lacks pTET; LuxR is introduced in purified form here.
*Construct 2 - simpler in nature, lacks pTET; LuxR is introduced in purified form here.<br>
 
~~Here explain briefly why Construct 2 was selected.


==Selection of model structure==
==Selection of model structure==

Revision as of 05:43, 20 October 2007

Model Development for Infector Detector

Formulation of the problem

As described earlier, Infector Detector (ID) is a simple biological detector, which serves to expose bacterial biofilm. It functions by exploiting the inherent AHL production employed by the quorum-sensing bacteria, in the formation of such structures.
Our project attempts to improve where previous methods of biofilm detection have proven ineffective: first and foremost, by focussing on the sensitivity of the system, to low levels of AHL production (bacterial chatter). In doing so, a complete investigation of the level of sensitivity to [AHL] needs to be performed - in other words, what is the minimal [AHL] for appreciable expression of reporter protein. Furthermore, establish a functional range for AHL detection. How does increased [AHL] impact on maximal output of reporter protein?
Also, how can the system performance be tailored, by exploiting the remaining state variables (e.g. varying initial [LuxR] and/or [pLux]).

The system performance here revolves most importantly around AHL sensitivity; however, the effect on, maximal output of fluorescent reporter protein and/or response time is, likewise, of great importance.

Our approach, involves the proposal of two simple constructs, varying with respect to the manner in which LuxR is introduced into the system:

  • Construct 1 - represented by T9002, incorporates constitutive expression of LuxR by pTET.
  • Construct 2 - simpler in nature, lacks pTET; LuxR is introduced in purified form here.

~~Here explain briefly why Construct 2 was selected.

Selection of model structure

  • Present general type of model
  1. is the level of description macro- or microscopic
  2. choice of a deterministic or stochastic (!) approach
  3. use of discrete or continuous variables
  4. choice of steady-state, temporal, or spatio-temporal description
  • determinants for system behaviour? - external influences, internal structure...
  • assign system variables

Assumptions

  • Ignore spatial information of the system; we ignore molecular dynamics of the system.
  • Keep track of number of molecules of each type - concentrations of these state variables.
  • Thus assume that the system is homogeneous - well-stirred, so that the molecules of each type are spread uniformly throughout spatial domain. *assume thermal equilibrium
  • assume constant volume of spatial domain

Our models

  • Introduction

We can condition the system in various manners, but for the purposes of our project, Infector Detector, we will seek a formulation which is valid for both constructs considered.

Our initial approach assumed that energy would be in unlimited supply, and that our system would eventually reach steady-state (Model 1). Experimentation suggested otherwise; our system needed to be amended. This lead to the development of model 2, an energy-dependent network, where the dependence on energy assumed Hill-like dynamics:

Model 1: Steady-state is attained; limitless energy supply (link here to derivation)

[math]\displaystyle{ \frac{d[LuxR]}{dt} = k_1 + k_3[A] - k2[LuxR][AHL]- \delta_{LuxR}[LuxR] }[/math]


[math]\displaystyle{ \frac{d[AHL]}{dt} = k_3[A] - k2[LuxR][AHL]- \delta_{AHL}[AHL] }[/math]

[math]\displaystyle{ \frac{d[A]}{dt} = -k_3[A] + k2[LuxR][AHL]- k_4[A][pLux] + k_5[AP] }[/math]

[math]\displaystyle{ \frac{d[P]}{dt} = -k_4[A][P] + k_5[P] }[/math]

[math]\displaystyle{ \frac{d[AP]}{dt} = k_4[A][pLux] - k_5[AP] }[/math]

[math]\displaystyle{ \frac{d[GFP]}{dt} = k_6[AP] - \delta_{GFP}[GFP] }[/math]

Model 2: Equations developed through steady-state analysis; however due to limited energy supply, we operate in the transient regime

[math]\displaystyle{ \frac{d[LuxR]}{dt} = k_1\bigg(\frac{[E]^n}{K_E^n + [E]^n}\bigg) + k_3[A] - k_2[LuxR][AHL]- \delta_{LuxR}[LuxR] }[/math]
[math]\displaystyle{ \frac{d[AHL]}{dt} = k_3[A] - k_2[LuxR][AHL]- \delta_{AHL}[AHL] }[/math]

[math]\displaystyle{ \frac{d[A]}{dt} = -k_3[A] + k_2[LuxR][AHL]- k_4[A][P] + k_5[AP] }[/math]

[math]\displaystyle{ \frac{d[P]}{dt} = -k_4[A][P] + k_5[P] }[/math]

[math]\displaystyle{ \frac{d[AP]}{dt} = k_4[A][P] - k_5[AP] }[/math]

[math]\displaystyle{ \frac{d[GFP]}{dt} = k_6[AP]\bigg(\frac{[E]^n}{K_E^n + [E]^n}\bigg) - \delta_{GFP}[GFP] }[/math]

[math]\displaystyle{ \frac{d[E]}{dt} = -\alpha_{1}k_1\bigg(\frac{[E]^n}{K_E^n + [E]^n}\bigg) - \alpha_{2}k_6[AP]\bigg(\frac{[E]^n}{K_E^n + [E]^n}\bigg) }[/math]


where:

[A] represents the concentration of AHL-LuxR complex
[P] represents the concentration of pLux promoters
[AP] represents the concentration of A-Promoter complex
k1, k2, k3, k4, k5, k6 are the rate constants associated with the relevant forward and backward reactions
[math]\displaystyle{ \alpha_i \ }[/math] represents the energy consumption due to gene transcription. It is a function of gene length.
n is the positive co-operativity coefficient (Hill-coefficient)
[math]\displaystyle{ K_E \ }[/math] the half-saturation coefficient



The system of equations for the two constructs varies strictly with respect to the value of the parameter k1. Construct 1 possesses a non-zero k1 rate constant, whereas for construct 2, a zero value is assumed.

Generalities of the Model

Simulations

Sensitivity Analysis