Protocol(Status: ???)
- define status: Work in Progress / Feedbacks Required / Validated (other tags ?)
Day 1
Equipment
- 7ml sterile tubes x4
- 1.5ml Eppendorf tube x1
- Incubator 37oC
- Gilson Pipettes
Reagents
- E.coli BL21; culture containing pTet-LuxR-pLux-GFP
- LB medium
- Ampicillin stock (50 mg/ml)
- AHL stock
Innoculation of Media
- Inoculate 10ul of stored parts in individual 2ml LB medium containing 2ul of ampicillin
- Incubate at 37°C for overnight in a shaker. (This is to get a good stock of cells for use in the experiment. After the overnight culture the cells will be in stationary phase)
Preparation of diluted series of AHL
http://parts.mit.edu/registry/images/4/4c/F2620-TF-Small.png
(Taken off BBa_F2620. Results show required dilution of AHL solution)
- Add 2µl of AHL stock solution to 200µl of cell samples.
Day 2
Equipment
- Water bath @ 37°C
- Stripettes
- Well-plate x1
- Stop watch
Reagents
- LB medium
- Ampicillin stock (50 mg/ml)
- 10μM AHL stock
- 100μM AHL stock
- GFP stock solution
- ddH2O
Preparation of diluted GFP standard solution
- Add 995ul of ultra pure water an eppendorf tube, together with 5ul of undiluted GFP standard solution and mix. (This gives a 200x dilution to be used as a positive control)
Loading Plate
- Transfer 200 µl aliquots of each of the cultures to a flat-bottomed 96 well plate. (Follow the schematic as shown)
- Three wells to be filled with 200µl of media to measure the absorbance background.
- Three further wells to be filled with 200 µl of (media + empty-vector culture) to measure fluorescent background. (IS THIS POSSIBLE??!?!)
- Standard GFP solution added as a positive control.
- Add 2µl of stock concentrations of AHL (10μM & 100μM) to the respective wells as shown.
- Place the top on the plate and centrifuge for 1 minute
- Remove lid and measure in the flourometer.
- (Fluorescence measurements - 488 nm excitation filter, 525 nm emission filter, 0.5 seconds, CW lamp energy 12901 units)
- Repeat the measurement a further two times straight after each other (This is to test the variability of the machine)
- Place lid back on and place back in the incubator at 30oC
Schematic
|
Collecting Data
- After 5 minutes of incubation measure the fluorescence by repeating procedure 3-5 above.
- Repeat measurements after every 5 minutes until the fluorescence is constant
- Before every measurement in the fluorometer spin the plates in a plate centrifuge
- Save data file from computer
- Copy and paste the data into an Excel spreadsheet for data analysis