IGEM:IMPERIAL/2007/Experimental Design/Phase1/Results 2.1
In Vitro Tetsing
Aim
The aims of this experiment is to test the following constructs in vitro at 37°C To Determine if the following constructs work in vivo:
After this testing we will test working constructs at 10°C and 37°C. In addition we want to identify any problems with our testing method
Both constructs were tested in vitro on *pTet and pT7 in vitro Tested 21-08-2007 to Tested 23-08-2007
pTet was tested in vitro at 10°C and 45°C Tested 21-08-2007
Results
pTet-GFP(100ng/μl)
Test: 21-08-2007
37 Degrees
We tested pTet-GFP in vitro in commercial S30 Cell Extract at 37 °C. The initial test was carried out over a period of 6 hours, during which measurements were taken every hour. The positive control of GFP diluted in water shows a typical expotential decay. The negative control remains relativly constant, however it does increase over the duration of 4 hours.
The Graph to the left shows the following data: Fluorescence of the GFP diluted in water solution (+ve control to show if fluoreometer is set correctly for GFP)
The average fluorescence of the pTet samples(3)
The fluoresence of a solution containing only S30 cell extract (-ve control).
|
Test: 21-08-2007 to Test: 23-08-2007
37 Degrees
The pTet-GFP in vitro samples were left and restested over three days to test to see what a typical expression curve looks like. The results of the average fluorescence of the samples and the positive control are shown to the left.
The graph on the left shows the following data: Fluorescence of the diluted GFP solution. (+ve control)
The average fluorescence of the pTet samples(3)
|
Test: 22-08-2007
10 Degrees
We tested pTet-GFP in vitro in commercial S30 cell extract at 10°C for 4 hours, sampling every 30 minutes. The results show us that the pTet-GFP does not work at 10 °C. The fluorescence of the samples remains nearly constant to that of the negative control. However, the negative control and the sample show slight variation around the basal level. The positive control shows a decay over the four hours, however because of the short sampling time we cannot tell whether this decay is expotential.
The graph the the right corresponds to the following: Positive Control - Fluorescence of the diluted GFP solution
The average fluorescence of the pTet samples(3)
Negative Control - The fluoresence of a solution containing only S30 cell extract
|
Test: 22-08-2007
45 Degrees
We tested pTet-GFP in vitro in commcercial S30 extract at 45°C for 4 hours, sampleing every 30minutes.
The results show that there minimal expression of GFP at 45°C. The sample only slightly increases above the negative control showing minimal expression. The positive control shows decay, we cannot tell if this decay is expotential because of the short sampling time. Interestingly there is even greater variation within the results, giving very unpreditable trend lines. The results to the left show the followig Positive Control - Fluorescence of the diluted GFP solution
The average fluorescence of the pTet samples(3)
Negative Control - The fluoresence of a solution containing only S30 cell extract
|
pT7-GFP In Vitro (100ng/μl)
37 Degrees
The pT7 was tested in vitro in commercial S30 Cell extract at 37oC for 4 hours. The samples initially showed a higher fluorescence than that of the control, however, both control and samples decreased. The positive control showed a decay over 4 hours of measuring. The graph on the left dispays the following. Fluorescence of the diluted GFP solution. (+ve control)
The average fluorescence of the pT7 samples(3)
The fluoresence of a solution containing only S30 cell extract (-ve control).
Overall though, the fluorescence readings were minimal compared to pTet.It can thus be concluded that the pT7 construct does not work in vitro with the commercial S30 cell extract.
|