*'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL | *'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL | ||
*The protocols for the experiment can be found [[IGEM:here|here]] | *The protocols for the experiment can be found [[IGEM:here|here]] | ||
*The [[ | *The [[Media:IC 2007 PLux in-vitro 05-10 25oC.xls|results]] of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM. | ||
*It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been: | *It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been: | ||
**The reaction was not mixed properly or the right amounts were not pipetted | **The reaction was not mixed properly or the right amounts were not pipetted | ||
**The plates had already been used and thus could have affected the reaction | **The plates had already been used and thus could have affected the reaction |
Latest revision as of 14:14, 21 October 2007
pTet-LuxR-pLux-GFP construct in-vivo
- Aim: The aim of the test was to check if construct 1 of infector detector works in-vivo
- The protocols for the experiment can be found here
- The results of the test showed that pTet-LuxR-pLux-GFPmut3b is working in vivo and GFPmut3b produced increases with increasing [AHL]
pTet-LuxR-pLux-GFP construct in-vitro
- Aim: The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL
- The protocols for the experiment can be found here
- The results of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM.
- It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been:
- The reaction was not mixed properly or the right amounts were not pipetted
- The plates had already been used and thus could have affected the reaction