==Phase 1: Intial Testing==
==Phase 1: Intial Testing==


Phase 1 involves the testing of various simple constructs to confirm that there is gene expression ''in vitro'' and ''in veso''. DNA constructs are as summarized below:
Phase 1 involves the testing of various simple constructs to confirm that there is gene expression ''in vivo'' and ''in vitro''. DNA constructs are as summarized below:


{|{| style="background:#F5FAFF; border: 1px solid #aabadd; color:Black"
{|{| style="background:#F5FAFF; border: 1px solid #aabadd; color:Black"
Line 85: Line 85:
<br>
<br>


Firstly we will test the promoters using the ''in vitro'' system. We are not interested in a lot of details, but rather just trying to see the most suitable promoter. The promoter construct, together with the inducer required (if the promoter is inducable) will be mixed together and the levels of fluorescence will be monitored over time. <br>
We are not interested in a lot of details, but rather just trying to see the most suitable promoter. The promoter construct, together with the inducer required (if the promoter is inducable) will be mixed together and the levels of fluorescence will be monitored over time in different chassis. <br>
*3 repeats to be done for each test
*Positive control: Purified GFP in E.coli, and then in the cell extract
*Negative control: Cell extract without any DNA insert or GFP
 
The best promoter sequence is defined as such:<br>
*Fastest expression of GFP
*Highest detection of fluorescence


We preferably want to use a constitutive promoter for Cell by Date. If all constitutive promoters are found working then we will need to chose one of them. This decision can be made based on their levels of activity (the higher, the better) and their operating temperature range. This needs to be as close as possible to the CBD operating range of 4&deg;C - 37&deg;C <br>
We preferably want to use a constitutive promoter for Cell by Date. If all constitutive promoters are found working then we will need to chose one of them. This decision can be made based on their levels of activity (the higher, the better) and their operating temperature range. This needs to be as close as possible to the CBD operating range of 4&deg;C - 37&deg;C <br>


==Phase 2: Characterizing specific Construct==
==Phase 2: Characterizing specific Construct==
Once the best promoter has been chosen, we would then proceed to characterize it in the ''in vitro'' systems. Several variables will be tested for, including:<br>
*Test for temperature operating range: 4°C, 15°C, 25°C, 37°C, 45°C, 60°C.
*Life span of the system


Fluorescence level readings will be taken every 15 min intervals, with triplicates for each sample at a particular temperature. Determining the rate of fluorescence at each temperature would also provide preliminary data for modelling analysis.


The system is then subjected to temperature changes and the effect on fluorescence levels measured:<br>
*Subject system to temperature changes and measure effect on fluorescence levels
*Type of gradients: Steep/ Gentle/ Pulse
*Temperature increment: from 4°C to 25°C
*Apply the temperature increment only after the GFP levels have reached steady state


===Problems===
*The commercial cell extracts come in 50µl, while the wells in the fluorometer plates can hold up to 200µl.
*Water evaporates when fluorescent readings are taken.




==Phase 3: Testing/Validation of Modelling Analysis==
Ideally, phase 2 would provide the results necessary for constructing our model for the system. The model should also be able to accurately predict the outcome of our temperature effects and verified through experimental testing. We would then obtain the thermal exposure device that achieves the specifications that we have defined for the project.


Phase 2 and 3 is to be repeated using DsRed-Express as the reporter. This is subjected to the arrival of its gene sequence, and its preparation and performance overall as a better reporter (due to its stability and quicker detection time).


 
===Considerations for DsRed-Express===
 
*When Dsred Express gene sequence arrives, clone and express it.
 
*Draw up a calibration curve of DsRed-Express.
 
*Positive control: DsRed-Express in cell extract
 
*Negative control: Cell extract only
 
 
 
 
 
 
=NOT APPLICABLE=
 
 
=== 2A : Gradient ===
====Introduction====
Having used the data collected from Phase 1 and simulated changes of temperature in the accumulation of reporter gene in model studies, we proceed on to test and validate our findings in Phase 2 where the device is exposed to varying temperature conditions. Since we have already calibrated our device in Phase 1, there is no requirement for further calibration unless a different reporter gene is used. Therefore the higher the exposure to increased temperature conditions, the faster the system will move along a graded colour scheme that has been calibrated in Phase 1. If this can occur without false positives, then it has achieved the objectives that we have set in our specifications.
 
====Design Parameters====
*Temperatures: Focus on varying exposure
**Ramp analysis
**Pulse
**Step
**Sqaure pulse
*Testing and validation of our model studies and data analysis
*Prevention of false positives (indicator reads "off" when it is not)
 
 
=== 2B : Discrete Colour Change ===
* Builds on 2A by having a discrete colour change when meat is spoilt.
 
* Discrete Change occours when meat is exposed to room temperature (25<sup>o</sup>C) for more than two hours
 
More info to be added!
 
 
==Phase 3 : General Meat Heat Exposure Device / Abstraction for re-usability==
 
More info to be added!

Revision as of 18:04, 12 August 2007

Cell by Date: Design


Summary

Cell by Date has three levels of complexity and we hope to implement these levels in separate chassis: E. coli, in vitro and in veso. These chassis are being characterized as one of ICGEMs sub-projects. The table below outlines which levels which hope to implement Cell by Date in.

Chassis Phase 1 Phase 2 Phase 3
E.coli X
In-Vitro X X X
In-Veso X X X


Phase 1: Intial Testing

Phase 1 involves the testing of various simple constructs to confirm that there is gene expression in vivo and in vitro. DNA constructs are as summarized below:

Type of Promoter Test Constructs Notes
Constitutive T7 Promoter
PT7 promoting GFP
PT7 promoting GFP
  • Entire construct is currently available in Biobricks Registry: BBa_E7104 (available), in pSB1A2 (AmpR)
  • pT7 can be used with T7 RNAP in vitro and in veso, and it gives constitutive expression.
Constitutive E.coli Promoter
Ptet</sub promoting GFP
Ptet</sub promoting GFP
  • Entire construct is currently in Biobricks Registry: BBa_I13522 (available), in pSB1A2 (AmpR)
  • pTet can be used with E.coli RNAP in vitro and maybe in veso, and it gives constitutive expression.
Inducible E.coli Promoter
PBad promoting GFP
PBad promoting GFP
  • pBad promoter and GFP available: BBa_J5528 (available), in pSB2K3 (KanR)
  • Need Ara C regulator protein in vitro and in veso. Ara C available with the RBS:BBa_S03550
  • pBad can be used with E.coli RNAP in vitro, and it is inducible by arabinose.
  • To be used in veso, arabinose transport proteins have to be inserted in the phospholipid bilayer of the vesicles.
Constitutive E.coli Promoter
PcI promoting GFP
PcI promoting GFP
  • Entire construct is currently available in Biobricks Registry: BBa_J07037 (avaiable), in pSB2K3 (KanR)
  • pcI gives constitutive expression.
Constitutive E.coli Promoter
pBad promoting GFP and pcI promoting araC
pBad promoting GFP and pcI promoting araC


We are not interested in a lot of details, but rather just trying to see the most suitable promoter. The promoter construct, together with the inducer required (if the promoter is inducable) will be mixed together and the levels of fluorescence will be monitored over time in different chassis.

  • 3 repeats to be done for each test
  • Positive control: Purified GFP in E.coli, and then in the cell extract
  • Negative control: Cell extract without any DNA insert or GFP

The best promoter sequence is defined as such:

  • Fastest expression of GFP
  • Highest detection of fluorescence

We preferably want to use a constitutive promoter for Cell by Date. If all constitutive promoters are found working then we will need to chose one of them. This decision can be made based on their levels of activity (the higher, the better) and their operating temperature range. This needs to be as close as possible to the CBD operating range of 4°C - 37°C


Phase 2: Characterizing specific Construct

Once the best promoter has been chosen, we would then proceed to characterize it in the in vitro systems. Several variables will be tested for, including:

  • Test for temperature operating range: 4°C, 15°C, 25°C, 37°C, 45°C, 60°C.
  • Life span of the system

Fluorescence level readings will be taken every 15 min intervals, with triplicates for each sample at a particular temperature. Determining the rate of fluorescence at each temperature would also provide preliminary data for modelling analysis.

The system is then subjected to temperature changes and the effect on fluorescence levels measured:

  • Subject system to temperature changes and measure effect on fluorescence levels
  • Type of gradients: Steep/ Gentle/ Pulse
  • Temperature increment: from 4°C to 25°C
  • Apply the temperature increment only after the GFP levels have reached steady state

Problems

  • The commercial cell extracts come in 50µl, while the wells in the fluorometer plates can hold up to 200µl.
  • Water evaporates when fluorescent readings are taken.


Phase 3: Testing/Validation of Modelling Analysis

Ideally, phase 2 would provide the results necessary for constructing our model for the system. The model should also be able to accurately predict the outcome of our temperature effects and verified through experimental testing. We would then obtain the thermal exposure device that achieves the specifications that we have defined for the project.

Phase 2 and 3 is to be repeated using DsRed-Express as the reporter. This is subjected to the arrival of its gene sequence, and its preparation and performance overall as a better reporter (due to its stability and quicker detection time).

Considerations for DsRed-Express

  • When Dsred Express gene sequence arrives, clone and express it.
  • Draw up a calibration curve of DsRed-Express.
  • Positive control: DsRed-Express in cell extract
  • Negative control: Cell extract only