Klapperich Lab:Cell Counting Procedure
From OpenWetWare
Overview
How to count cells using Hemocytometer.
Materials
List reagents, supplies and equipment necessary to perform the protocol here. For those materials which have their own OWW pages, link to that page. Alternatively, links to the suppliers' page on that material are also appropriate.
- supply 1 (i.e. tubes of a certain size? spreaders?)
- reagent 1
- X μL reagent 2
- component A (reagent 2 is made up of multiple components)
- component B
- equipment 1
- equipment 2
Procedure
- Aspirate media.
- Wash with 1X PBS.
- Aspirate PBS.
- Resuspend in media – make sure cells are completely resuspended, that they are not clumped together.
- Place coverslip on middle of hemocytometer.
- remove 500 ul of cells to microfuge tube.
- Add 50 ul of cell solution to 50 ul of trypan blue solution in a second microfuge tube.
- Add 20 ul of the final solution to each side of the hemocytometer. by letting a drop of liquid get taken into the slid by capillary action.
- Place hemocytometer on scope at 10X magification
- Locate center 5 x 5 grid.
- Move to higher power.
- Count all of the viable cells in the 5 x 5 grid. It is easier to count at higher power. Dead cells will be dark blue.
- Count the cells in two other 1 mm2 areas (one of the squares surrounding the center square).
- Average the values for the final count.
Notes
- List troubleshooting tips here.
- You can also link to FAQs/tips provided by other sources such as the manufacturer or other websites.
- Anecdotal observations that might be of use to others can also be posted here.
Please sign your name to your note by adding ('''~~~~''') to the end of your tip.
References
Relevant papers and books
- Goldbeter A and Koshland DE Jr. An amplified sensitivity arising from covalent modification in biological systems. Proc Natl Acad Sci U S A. 1981 Nov;78(11):6840-4. DOI:10.1073/pnas.78.11.6840 |
- JACOB F and MONOD J. Genetic regulatory mechanisms in the synthesis of proteins. J Mol Biol. 1961 Jun;3:318-56. DOI:10.1016/s0022-2836(61)80072-7 |
- ISBN:0879697164
Contact
- Who has experience with this protocol?