Lidstrom:Colony PCR: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
No edit summary
Line 8: Line 8:
*If they aren't working, you can put them in tubes, put them at 95oC for a while, then centrifuge they lysed cells so all the debris falls out.  Run PCR from on the aqueous portion.     
*If they aren't working, you can put them in tubes, put them at 95oC for a while, then centrifuge they lysed cells so all the debris falls out.  Run PCR from on the aqueous portion.     


*[[User:Janet B. Matsen|Janet]] is using NEB's [http://www.neb.com/nebecomm/products/productM0486.asp OneTaq] quick-load (not hot start) & their recommended [http://www.neb.com/nebecomm/appNotes/appnoteM0486.pdf|protocol protocol]
*[[User:Janet B. Matsen|Janet]] is using NEB's [http://www.neb.com/nebecomm/products/productM0486.asp OneTaq] quick-load (not hot start) & their recommended [http://www.neb.com/nebecomm/products/productM0486.asp|protocol protocol]


==Parameters:==
==Parameters:==

Revision as of 14:06, 3 February 2012

Back to Protocols

General:

  • Use Taq. It is cheap. Do not use Phusion. It is ~$1/50uL rxn. Taq is less accurate & less fast but that's fine.
  • The thermocycling denaturation & extension temperature should be that recommended by your particular PCR kit. I have seen 68oC & 72oC.
  • The primer concentration varies in different people's recipes. Janet hasn't tested variations.
  • One fatal flaw: overloading the PCR. Just a tiny piece of a colony should be used.
  • If they aren't working, you can put them in tubes, put them at 95oC for a while, then centrifuge they lysed cells so all the debris falls out. Run PCR from on the aqueous portion.

Parameters:

  • T_anneal: up to you. For VF2 & VR 54-56oC works well.
  • t_anneal: use 30s/kb and round up.
  • rxn volume: 10-25 uL. Too small of a volume can result in overloading without noticing.
  • Stay tuned for an image of what "overloading" can look like!