M465:16S rRNA gene lab work: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
Line 122: Line 122:


**Note that Loading dye contains glycerol to keep our sample in the lane rather than floating away and will have one of 3 marker dyes (bromophenol blue, xylene cyanol, or orange G) that facilitate estimation of DNA migration distance and optimization of agarose gel run time. 1x TBE buffer is used in this electrophoretic separation (89mM Tris, 89mM Boric acid, 2.0mM EDTA. The gel will be run at 120V for approximately 30 minutes. <BR><BR>
**Note that Loading dye contains glycerol to keep our sample in the lane rather than floating away and will have one of 3 marker dyes (bromophenol blue, xylene cyanol, or orange G) that facilitate estimation of DNA migration distance and optimization of agarose gel run time. 1x TBE buffer is used in this electrophoretic separation (89mM Tris, 89mM Boric acid, 2.0mM EDTA. The gel will be run at 120V for approximately 30 minutes. <BR><BR>
=='''Clean up of your PCR product'''==
Before we can sesquence our bacterial 16s rRNA genes, we must remove interfering dNPTs, primers, and other small degraded DNA. We will use a column that separates DNA by size. Since the reagents and column materials in the kit we will use are proprietary, we won't know exactly what is going on at each step but, basicially, we will apply our pcr product to a column of a particular density, wash away elements too small to be trapped in it, and elute off the larger fragments of DNA (that should be ~1500bps if our pcr amplification of the 16s rRNA genes in our soil genomic DNA was successful).
'''Notes before Starting:'''<BR>
95% ethanol  has been added to Buffer PE before first time use (see bottle label for volume).<BR>
All centrifuge steps are carried out at 17,900rfc (~13,000 rpm in a microcentrifuge) in a conventional tabletop microcentrifuge at room temperature.<BR>
'''Procedure'''<BR>
1. Add 5 volumes of Buffer PB to 1 volume of the PCR reaction and mix.  Because our PCR reactions are 20 ul volume, we will be adding  100 ul of buffer PB to the tubes. <br> <br>
2. Place a QIAquick column in a 2 ml collection tube. <br> <br>
3. To bind the DNA to the column, apply the sample to the surface of the QIAquick column and centrifuge for 30-60 seconds. <br> <br>
4. Discard the flow-through and place the QIAquick column back in the same tube. <br> <br>
5. To wash, add 750 ul of buffer PE to the QIAquick column and centrifuge for 30-60 s.  Discard the flow-through and place the column back in the same tube. <br> <br>
6. Centrifuge the column once more in the provided 2 ml tube to remove residual wash buffer. <br> <br>
7. Place each QIAquick column in a clean, 1.5 mL microcentrifuge tube. <br> <br>
8. To elute DNA, add 50 ul of buffer EB to the surface of the column - make sure to place this volume at the center of the membrane. Centrifuge the column for 1 minute. <br> <br>
9. The purified DNA should now be at the bottom of your 1.5 mL tube. Discard the column. <br> <br>
''IMPORTANT NOTES for using this kit: Ensure that the elution buffer (EB) is dispensed directly onto the spin column membrane for complete elution of bound DNA. The average eluate volume is 48 μl from 50 μl elution buffer volume.''<BR>
''Elution efficiency is dependent on pH. The maximum elution efficiency is achieved
between pH 7.0 and 8.5. Store DNA at –20°C as DNA may degrade in the absence of a buffering
agent. ''<BR><BR>
Make sure your pcr product is clearly labeled. Your instructor will measure the new DNA conc. using the nanodrop and post those concentrations for you in ng/μL. In the next lab you will use these amplified products for direct sequencing via the BigDye reaction. <br>

Revision as of 13:29, 19 February 2014


M465

Home        People        Resources        Schedule        Lab Safety        Links to Labs       

Creating Lysates from your Isolates

One of the big advantages of the molecular revolution in microbial ecology is that we can actually find, based on 16S rRNA gene sequences, the identity of your isolates. In order to do that, we will follow the protocol below which first involves liberating the DNA in your isolate, then amplifying the 16S rRNA gene, then sequencing it. The bioinformatics analysis of this sequence will be covered next time we meet.

Isolate Genomic DNA From Your Sample
Please wear gloves during this protocol

1. For each of your isolates, label a 200 ul PCR tube and fill it with 100 ul of water.
2. Using a sterile loop, transfer a small bit (barely visible) of your isolate into the 100 ul solution in the PCR tube - make sure to shake the isolate off the loop so that it is in the water
3. Cap and vortex the PCR tube for 10 seconds.
4. Place in the PCR machine at 95C for 10 minutes.

Storing DNA:
Because you've just made a lysate of your isolate, remember that this solution contains all cellular contents, including DNAses -- enzymes that break down that very DNA we are trying to amplify. You can store your lysates at -20C in the freezer in the lab but make sure to create new ones if you freeze-thaw them more than once.

We will next attempt to amplify only bacterial rRNA genes by using "universal" bacterial primers :a forward primer, Eub27F (5′–3′:AGA GTT TGA TCC TGG CTC AG) , and a reverse primer, Eub1492R (5′–3′: ACG GCT ACC TTG TTA CGA CTT). These primers are short sequences of single stranded DNA that are complementary in sequence to areas of the 16s rRNA gene. The 16S rRNA gene sequence is particularly good target gene for amplification because this gene (encoding a ribosomal subunit) contains conserved sequences of DNA common to all bacteria (to which the primers are directed) as well as divergent sequences unique to each species of bacteria (allowing identification of the bacterial species from sequence databases and sequence identifying software). Our "universal" primers will anneal to most bacterial DNA and initiate an exponential amplification of the 16s rRNA gene from the template DNA. After 30 cycles of polymerase chain reaction in a thermal cycler, the result will be a pcr product containing hundreds, if not thousands, of the 16s rRNA gene.

PCR Amplification of 16s rRNA genes from Universal Bacterial Primers

To review how the polymerase chain reaction works and how it exponentially amplifies specific sequences of DNA, go to the following web site:
PCR animation http://www.dnalc.org/resources/animations/pcr.html

All PCR reactions require a thermal cycler to elevate and reduce the reaction temperature quickly and keep it at a specific temperature for a prescribed amount of time. There is a basic pattern to these temp. cycles, but there are differences, so you must be sure to program the cycler with the correct time and temperature for your specific amplification. Traditionally, pcr used Taq polymerase, a heat stable DNA polymerase originally found in a extremophilic bacterium, Thermus aquaticus, that lives and reproduces in boiling hot springs. We are not using Taq for our pcr but a different polymerase, Finnzyme's Phusion High-Fidelity Polymerase, a proprietary reagent that uses a novel heat-stable Pyrococcus-like enzyme. Phusion DNA Polymerase generates long templates with a greater accuracy and speed than with Taq. The error rate of Phusion DNA Polymerase in Phusion HF Buffer is determined to be 4.4 x 10-7, which is approximately 50-fold lower than that of Thermus aquaticus DNA polymerase, and 6-fold lower than that of Pyrococcus furiosus, another proof-reading DNA polymerase. Therefore, our pcr product DNA will have far fewer "mistakes" in the sequences that are replicated from template DNA. Our polymerase will also work much faster so our ~20 cycles will require less time than conventional Taq based pcr.

Protocol for PCR
Obtain a tiny 0.2ml pcr tube from your instructor. All of the ingredients listed below in the table, except the template DNA, have been added together previously and kept on ice for you in these tubes.

Label it with a fine tipped Sharpie on the top and side with the code name for your isolate. Do not use tape.

you will add 4 μL of lysate to your PCR tube with master mix. Since your pcr tube already has 10μL master mix, 4μL DNAase free water, and 1μL of each of 2 primers, the total reaction volume for everyone will be 20μL.

It is very important to pipet these tiny volumes accurately. Use the P10 or P20 pipettes. Look at the tip after you draw up your measured volume to make sure you have liquid there.

Dispense the template DNA into the liquid directly, watching to make sure that the liquid has left the pipette tip.

Tap the bottom of the tube (VERY GENTLY!) and flick the tube to mix. Do not treat these tubes roughly as they are quite thin-walled and can break or crack.

Bring your tube to your instructor; they will show you where the thermal cycler is located in JH 022. Your instructor will start the reaction when everyone's tubes are loaded.

Component TABLE

Component amt. in a 20 μl
reaction
Final Conc.
Purified
DNAase free
Water
4 μL already in tube.
Want to achieve
total of 20 μl reaction vol.
Add from 0 - 3μl
_
2x Phusion Master Mix 10 μl 1x
27F primer 1 0.5 μMolar
1492R primer 1 0.5 μMolar
template DNA 4 μl optimum is 100ng of DNA/reaction


The cycling program is shown below.

Thermal Cycler Program:
3 step program

Cycle Step Temperature Time # of Cycles
Initial Denaturation 98C 5 min. 1
Denaturation
Annealing
Extension
98C
55C
72C
10 sec
30 sec
30 sec
30
Final Extension 72C
4C
10 min
Hold
1


While the 16S rRNA genes from all of the bacterial species in your DNA are being amplified in the thermal cycler, you will have about an hour to work on any other parts of your project.
After the PCR reactions are complete, you will need to complete a "Clean-Up" of your pcr products (remove the unused dNPTs, primer dimers, salts, etc. The instructions for using a kit to purify your pcr products and get them ready for sequencing next time. You will also need to set up a gel to assess the purity of your pcr product and the success of your amplification.

Agarose Gel Electrophoresis of Clean PCR product

To see if you successfully amplified the 16s rRNA gene and not anything else, you will "run a gel" on your cleaned pcr products. To run a gel means that we will perform an electrophoretic separation of the DNA fragments in your cleaned up pcr product, using a small fraction of the volume of your pcr product applied to a 1% agarose gel stained with Sybr Safe DNA stain. Your instructor will photograph the gel, label it with your amplicon id from the template and post the gel photo on OnCourse so you can evaluate your success at 16S rRNA gene amplification. You should see a single band of ~1.5kb indicating that the only dsDNA in your pcr product came from amplification of a ~1500bp gene fragment. Can you explain how we know the size of our amplified gene fragment?

Protocol for making a 1% agarose gel

In order to run out your PCR products you will first pour a 1% agarose gel. The recipe for the gel is 1.0% agarose (w/v) in 1x TBE buffer (10x=890mM Tris, 890mM Boric Acid, 20mM EDTA) with SybrSafe™ stain. Your instructor will add the SybrSafe stain to your molten agarose after you prepare it. Before you start, prepare your agarose gel, comb, and reservoir as you are instructed

Protocol: 1. Using a graduated cylinder, fill a glass, 250 mL flask with 100 mL of 1x TBE buffer.
2. Using the top loading balance, measure out 1 gram of Agarose
3. Pour the agarose into the flask containing the TBE buffer and stir to mix. The agarose won't go into solution here but needs to be heated
4. Place the flask inside the microwave and heat for 1 minute, maximum power. At the end of the minute, swirl the solution to mix and place back in the microwave.
5. Heat for 1 minute again, this time watching closely to make sure it does not boil. At the end, swirl to mix and bring to your instructor for the sybersafe dye
6. After your instructor adds the SyberSafe, pour your gel into the mould. It will take ~ 25 minutes to set.

DNA is uniformly negatively charged and will,therefore, move toward the positive electrode. The separation is determined by the size or mass of the molecule or fragments of DNA.




Procedure for Agarose Gel Electrophoresis of PCR products
1. Load 5 microliters of your PCR product on your gel by placing the 5 microliters of your pcr product as a spot on a small piece of parafilm and adding 5 microliters of loading dye (0.25% XC, 30% glycerol, 0.1mg/ml RNAase). Mix the loading dye by pipetting up and down on the spot, on the parafilm, before loading all 10 microliters into a lane of the 1% agarose gel.
2. Record which lane is loaded with which product. Be sure to leave the first two lanes and the last lane empty for the 1kbp ladder, the positive control and the negative water control.

    • Note that Loading dye contains glycerol to keep our sample in the lane rather than floating away and will have one of 3 marker dyes (bromophenol blue, xylene cyanol, or orange G) that facilitate estimation of DNA migration distance and optimization of agarose gel run time. 1x TBE buffer is used in this electrophoretic separation (89mM Tris, 89mM Boric acid, 2.0mM EDTA. The gel will be run at 120V for approximately 30 minutes.