==Method and Materials==
==Method and Materials==
===Equipment===
===Equipment===
{{SJK Comment|l=15:44, 6 December 2008 (EST)|c=All of the information is in this "equipment" section, very nice job.  My comments here are more "style" issues.  (1)  You don't need the phrase "in this experiment" (2) the customary way to cite companies is to say "...a constant deviation spectrometer (Company name, location (city)"  in this case, though, you may not be able to find the company location if it exists anymore (it's maybe Adam Hilger Ltd.).  You can link to the website via the references (so put a number and then in the references section give the nice website you found). (3)  You don't usually publish that "you were safe" but if there are important safety notes, it is really good to include it.  In this case, high voltage safety is common, and you don't have any special advice, so your safety comments would not help the reader.  (4) the phrase "turn on the apparatus..." is a "how to" whereas in a scientific report it should be "we did" statments (as in your previous sentence).}}
In this experiment we used a constant deviation spectrometer with a Pellin-Broca constant-deviation prism [http://www.abdn.ac.uk/virtualmuseum/pictures_show2.php?prefix=ABDNP&num=200584&firstview=true&mt=not&sign=%3Ex=&viewnumber=0&resultsperpage=9&termscount=1&listofterms], a spectrum tube power supply [http://www.electrotechnicproduct.com/science.html], and 3 spectral line tubes of three different elements: Hydrogen, Deuterium, Mercury.  Details of the materials used are in links.  We began by making sure that all instruments were functioning correctly, and (most importantly)made sure that we were in a safe environment.  We next  plugged in the power supply, and inserted the Hg tube as instructed by the manual.  Turn on the apparatus and allow it to heat for about a minute or so.
In this experiment we used a constant deviation spectrometer with a Pellin-Broca constant-deviation prism [http://www.abdn.ac.uk/virtualmuseum/pictures_show2.php?prefix=ABDNP&num=200584&firstview=true&mt=not&sign=%3Ex=&viewnumber=0&resultsperpage=9&termscount=1&listofterms], a spectrum tube power supply [http://www.electrotechnicproduct.com/science.html], and 3 spectral line tubes of three different elements: Hydrogen, Deuterium, Mercury.  Details of the materials used are in links.  We began by making sure that all instruments were functioning correctly, and (most importantly)made sure that we were in a safe environment.  We next  plugged in the power supply, and inserted the Hg tube as instructed by the manual.  Turn on the apparatus and allow it to heat for about a minute or so.



Revision as of 13:44, 6 December 2008

Balmer Series Analysis and the Rydberg Constant

SJK 14:56, 6 December 2008 (EST)

14:56, 6 December 2008 (EST)
This is good Title and Author information. The title could be improved slightly by being more specific, such as calculation of the Rydberg constant from the hydrogen balmer series...but it's pretty good as you have it. Room number is not necessary. On a published paper, contact information is so someone in principle can contact you about the paper.

Author: Manuel Franco Jr.

Experimentalist: David Eduardo Sosa and Manuel Franco Jr.

Location: Albuquerque, New Mexico, 87131, United States

University of New Mexico Department of Physics and Astronomy

800 Yale Blvd. NE

Room Number: 116

E-mail: eMJeF_2004@hotmail.com


Abstract

In this experiment, we determined the Rydberg Constant, compared hydrogen and deuterium, and analyzed the Balmer series. We compare our experimental value to the accepted value R = 1.0967758 × 107 m−1.SJK 15:07, 6 December 2008 (EST)

15:07, 6 December 2008 (EST)
this second sentence is a result and would typically be close to the end of the abstract. Also, it would be better to report your value for the Rydberg constant and say whether it's consistent with the accepted value.

We did this by using four wavelengths of the spectral line emissions of hydrogen in the Balmer series. These colors "reflect emissions of photons by electrons in excited states transitioning to the quantum level described by the principal quantum number n equals 2." (1)SJK 15:00, 6 December 2008 (EST)

15:00, 6 December 2008 (EST)
It is very good that you use quotes and cite your source here. However, direct quotations (using exact quote) are extremely rare in the abstract and also rare in the paper. So, you need to paraphrase in your own words.

Hydrogen and deuterium are compared to each other, and their experimental values are also compared to their accepted values. In running through the data concepts from the Balmer serious arise that contribute to the experiment. These concepts consist that "the Balmer series is characterized by the electron transitioning from n ≥ 3 to n = 2, where n refers to the radial quantum number or principal quantum number of the electron." (1)


Introduction

SJK 15:32, 6 December 2008 (EST)

15:32, 6 December 2008 (EST)
Your introduction as is is a brief history of the Rydberg constant...this is interesting, but it's only a small part of what your introduction should be. You should introduce the physics and importance of the constant (as you have done), then you should include: (1) discussion of ways of measuring the constant and the best methods for currently measuring the constant, along with the current accepted value (you will need citations to refereed publications), (2) a brief introduction to what you tried to do, and (3) a concluding statement, something like "our measurements were slightly inconsistent with the accepted value and we can improve these in future measurements by ..." Just to reiterate, you need to cite several original publications in the introduciton, not just wikipedia articles (which are not considered refereed, and which are considered "secondary" sources, not primary.).

In 1885, Johann Jakob Balmer, a mathematician, discovered this series of colors of hydrogen in the color spectrum, hence the Balmer series. He derived such equation based on his observations: http://upload.wikimedia.org/math/1/2/2/1223c57e48b6b6c0cf038dd69a22db64.png [1]

Three years after the discover of this series, Johannes Robert Rydberg, a physicist, would revise the equation and analyze the details of this phenomena. He would revise the equation to what we commonly known today: http://upload.wikimedia.org/math/0/a/c/0acd60cdab573b571c1a07ee23a8c0d7.png

He used this formula "to predict the wavelengths of photons... emitted by changes in the energy level of an electron in an atom." [2] He would later discover the constant slope in the wavelength over the quantum number transitions.

SJK 15:24, 6 December 2008 (EST)

15:24, 6 December 2008 (EST)
Is this really the number Rydberg found? It looks more like a modern accepted value. His number probably had much much more uncertainty. You will need to find a refereed publication (e.g. from that NIST CODATA site we were looking at) as a source of the accepted value.

He found the slope to be: http://upload.wikimedia.org/math/7/b/6/7b625152ea50ad187556f8d158b79aff.png

The constants are as follows:

[math]\displaystyle{ h \ }[/math] is the Planck's constant,

[math]\displaystyle{ m_e \ }[/math] is the rest mass of the electron,

[math]\displaystyle{ e \ }[/math] is the elementary charge,

[math]\displaystyle{ c \ }[/math] is the speed of light in vacuum, and

[math]\displaystyle{ \epsilon_0 \ }[/math] is the permittivity of free space. [3]

Apparently, both Johann and Johannes were Swiss, and both contributed to this discovery.

Method and Materials

Equipment

SJK 15:44, 6 December 2008 (EST)

15:44, 6 December 2008 (EST)
All of the information is in this "equipment" section, very nice job. My comments here are more "style" issues. (1) You don't need the phrase "in this experiment" (2) the customary way to cite companies is to say "...a constant deviation spectrometer (Company name, location (city)" in this case, though, you may not be able to find the company location if it exists anymore (it's maybe Adam Hilger Ltd.). You can link to the website via the references (so put a number and then in the references section give the nice website you found). (3) You don't usually publish that "you were safe" but if there are important safety notes, it is really good to include it. In this case, high voltage safety is common, and you don't have any special advice, so your safety comments would not help the reader. (4) the phrase "turn on the apparatus..." is a "how to" whereas in a scientific report it should be "we did" statments (as in your previous sentence).

In this experiment we used a constant deviation spectrometer with a Pellin-Broca constant-deviation prism [4], a spectrum tube power supply [5], and 3 spectral line tubes of three different elements: Hydrogen, Deuterium, Mercury. Details of the materials used are in links. We began by making sure that all instruments were functioning correctly, and (most importantly)made sure that we were in a safe environment. We next plugged in the power supply, and inserted the Hg tube as instructed by the manual. Turn on the apparatus and allow it to heat for about a minute or so.

Calibration

After setting up the equipment, we first start off by calibrating the spectrometer by using mercury (Hg) and the table of spectral lines of Hg (Lab Manual: Section 4.3).

Hg Spectral Lines

Color Wavelengths
Deep Violet 404.7 nm (hard to see)
Violet 435.8 nm
Blue-Green Skipped (very weak)
Green 546.1 nm
Yellow 577.04 nm
Yellow 579.0 nm
Red 690.75 nm

We first set the dial one of the wavelengths in the above table. We used the violet color because our data would deviate based on our initial calibration. Since violet is centric it would minimize data instrumental error. We used the other colors to confirm that it's properly calibrated. Then we aligned the colors using the cross hairs in the eyepiece. We adjusted the prism to align the cross hairs with the color as need. Once we calibrated the spectrometer, we adjusted the slit at the other end of the spectrometer to .7 mm. We adjusted the slit as we saw fit later on, but we stayed within the bounds of .5 and 1 mm. The narrower the slit, the color had a higher resolution, but the wider the slit, the color was somewhat blurred. As we were calibrating, Koch mention the us that the gears in the dial have what is called backlash. Backlash is were if you turn the dial clockwise, take a measurement, then counterclockwise there will be gap that will deviate your measurements. So when the spectrometer is calibrated, turn it going counterclockwise or clockwise and take measurements based on that initial direction. If you manage to pass your measurement, go back passing the measurement, and then turn it again stopping at the measurement. Stick to the original direction. All the data measurements have to be taken the same way initially. If we were to take a data point clockwise, or opposite to direction we initially used to calibrate, our data would be off by about 1 nm.

Hydrogen Spectrum Tube

Once we calibrated and backlash was reduced, we turn the power supply off. Then we change the Hg tube with the H tube. (CAUTION: The test tubes will get hot after extended periods of use. Minor burn is possible when handling them!) We turned the power supply back on. We will now record the wavelengths seen through the eye piece based on the Hydrogen. There are four bright and distinct lines: red, turquoise, bright violet, and a diminished violet. We saw something similar to this:

[6]

Deuterium Spectrum Tube

After taking several measurements of the wavelength from hydrogen, we repeat the process of replacing the test tubes. This time we took measurements from deuterium. The same colors appear as in hydrogen, and the wavelengths are about the same.

Data

The following measurements are the wavelengths for hydrogen and deuterium. The data was taken counterclockwise.

Hydrogen Measurements

Color Measurement 1 (nm) Measurement 2 (nm) Measurement 3 (nm) Measurement 4 (nm)
Red 657.8 659.9 659.5 659
Blue/Green 486 486 486.1 485.9
Violet 433.8 434 434.2 434.4
Dim. Violet 409.7 409.8 409.3 410.1

Deuterium Measurements

Color Measurement 1 (nm) Measurement 2 (nm) Measurement 3 (nm) Measurement 4 (nm)
Red 659 659.9 659.5 658.1
Blue/Green 485.9 485.9 486 486
Violet 434.2 434.2 434.2 434.2
Dim. Violet 409.8 409.7 409.8 409.3

Results and Discussion

Wavelengths of H and D

This is the Spread Sheet 1 in where I did all my data analysis for hydrogen and deuterium. The following table shows the colors of each wavelength with the averages and the uncertainties. I took the data and found an average for all corresponding wavelengths. Also found their S.E.M. (standard error of the mean), by taking the standard deviation of the mean and dividing the square root of the total number of data points.

Color Wavelengths for H Wavelengths for D
Red 656.1 +/- .5 nm 659.13 +/- .03 nm
Blue/Green 486.00 +/- .04 nm 485.95 +/- 0.03 nm
Violet 434.1 +/- .1 nm 434.2 +/- 0.1 nm
Dim. Violet 409.7 +/- .1 nm

409.65 +/- .12 nm

Determining the Rydberg constant

As for the Rydberg constant, I found the constant in this word Spread Sheet 2, and I obtained this graph for hydrogen. The calculated slope is 1.0975 (+/- .0003) × 10^7 m^-1.

I used this equation to find the slope http://upload.wikimedia.org/math/5/a/0/5a05645dc256a0aca0ab1c9cf97b6525.png [7].

I went through and calculated the individual slopes of each hydrogen wavelength, and compared it to the accepted value.

Conclusions

The experimental value for the Rydberg constant is 1.0975 (+/- .0003) × 10^7 m^-1, and the accepted value is 1.0967758 × 10^7 m−1. The percent difference between the values is .06%.

Koch, I did not calculate the value in for deuterium in the first lab of the Balmer series. So, when I take the new and improved data, I will calculate it for deuterium here in this spot.

References

Lab Manual: Sections 4.1-4.6

(1) Wikipedia article on Balmer Series

Wikipedia article on Rydberg Constant

Riveras Formal Report

Acknowledgments

I just want to thank Johann Jakob Balmer and Johannes Rydberg for make this discovery, for without this discovery I would not being doing this. I also wanna thank my my mom, my dad, my brothers, my dog. I want acknowledge Dr. Kock and Aram for taking the time to instruct us and show us how to go about this and other experiments. I want to thank the department of physics and astronomy, a.k.a. PandA, for providing the materials for this experiment.

Links

3 4

Question for Koch

  1. Why does Rivera take several measurements for mercury in his spreadsheet?