Physics307L:People/Mondragon: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
 
(17 intermediate revisions by 2 users not shown)
Line 1: Line 1:
This is my page for [[Physics307L|Junior Lab, Fall 2007]]. Links to my notebook and my main OWW page, where you can find contact info, below
This is my page for [[Physics307L|Junior Lab, Fall 2007]]. Links to my notebook and my main OWW page, where you can find contact info, below
==[[/Notebook|My 307L lab notebook]]==
==[[/Notebook|My 307L lab notebook]]==
[[/Notebook|My 307L lab notebook]]
[[/Notebook|My 307L lab notebook]]<p>
[http://www-hep.phys.unm.edu/~gold/phys307L/manual.pdf Quick link to lab manual here]
<pre><nowiki>[http://www-hep.phys.unm.edu/~gold/phys307L/manual.pdf Quick link to lab manual here]</nowiki></pre>


==[[User:Tomas A. Mondragon|My main OWW user page]]==
==[[User:Tomas A. Mondragon|My main OWW user page]]==
[[User:Tomas A. Mondragon]]
[[User:Tomas A. Mondragon]]
==The Poisson fit accuracy tests==
[[/Poisson |Poisson notebook]]
==[[/Formal Lab Report |Formal Lab report]]==
[[/Formal Lab Report | Formal Lab Report]]
==Oscilloscope Lab Summary==
==Oscilloscope Lab Summary==
Main notebook entry [[/Notebook/070829|here]].
Main notebook entry [[/Notebook/070829|here]].
Line 15: Line 23:


Further investigation can be done in how electrons lose energy to the helium in the bulb and how this effects radius.
Further investigation can be done in how electrons lose energy to the helium in the bulb and how this effects radius.
==Poisson Statistics summary==
{{SJK comment|label=01:46, 22 October 2007 (CDT)|comment=Outstanding work, Tomas!  Your work in getting the experiment working was a huge help, and the care and time you spent on data analysis are very evident.  Also, I am intrigued about the weird 27 count event you saw.  If you have a chance, get together with Nik and Bradley to see how their multi-day experiment turned out.}}
notebook entries [[Physics307L:People/Mondragon/Notebook/070926]] and [[Physics307L:People/Mondragon/Notebook/071003]]
Poisson distributions model count data of an experiment that count events during a dwell time that happen at random but do so at a definite average rate. (Nuclear decay, photon detection, etc.) [[Physics307L:People/Trujillo | Lorenzo Trujillo]] and I set up some gamma ray detection equipment inside of a lead shielded cavity and counted the events the equipment detected in 256 10ms, 20ms, 40ms, 80ms, 100ms, 200ms, 400ms, 800ms, 1s, and 10s time intervals. The data we collected fit Poisson distributions very well, and the average count numbers fit on a line on a average count number versus dwell time very well just like anything following a Poisson distribution should. We were counting, on average, 7.39 events per second. There was an interesting instance were we counted 27 events in a 200ms period, though. I wonder what caused that. Could it be some weird particle creation and annihilation event?
==Planck's Constant==
[[Physics307L:People/Mondragon/Notebook/071010]]
[[Physics307L:People/Mondragon/Notebook/071017]]
We calculated <math>h=3.77989*10^{-15}\pm 0.14521*10^{-15} \,eV*s</math> based on data collected from our experiment that took advantage of the photoelectric effect and the emmision spectrum of mercury vapor. The accepted value of <Math> h =\,\,\, 6.626\ 068\ 96(33) \times 10^{-34}\ \mbox{J}\cdot\mbox{s} \,\,\, = \,\,\, 4.135\ 667\ 33(10) \times10^{-15}\ \mbox{eV}\cdot\mbox{s}</math> is within three standard deviations of my calculated value. Looks like a systematic error.
==Speed of Light ==
[[Physics307L:People/Mondragon/Notebook/071024]]
[[Physics307L:People/Mondragon/Notebook/071031]]
==Excitation Levels of Neon==
[[Physics307L:People/Mondragon/Notebook/071107]]
[[Physics307L:People/Mondragon/Notebook/071114]]
Not much usefull data was gathered, probably the wiring was wrong.
I think this may be a graph of whats supposed to happen with reversed collector ring bias, bot its flipped around an only shows some nubs. No peaks.
Our resolution was 0.25 V. No peaks found.
[[Image:Negative bias.png]]
==Rydberg constant/Balmer Series summary==
Notebook entry [[Physics307L:People/Mondragon/Notebook/071121| here]]
The Balmer series is a sequence of lines in hydrogen's absorption/emission spectrum in the optical range that follows the relationship
:<math>\frac{1}{\lambda} = \frac{4}{B}\left(\frac{1}{2^2} - \frac{1}{n^2}\right) = R_\mathrm{H}\left(\frac{1}{2^2} - \frac{1}{n^2}\right), n=3,4,5,...</math>.
This relation was found by Johann Balmer and was later generalized by Johannes Rydberg. R<sub>H</sub> is the Rydberg constant for hydrogen, <math>\lambda</math> is the observed wavelength of one of the lines, and n is an integer corresponding to that particular line as well as the principal quantum number of the excited electron state that produces the line. The Balmer lines are produced by absorption or emission of electromagnetic energy due to changes in the excitation level of the hydrogen atom between the first excited state and higher energy states.
To make meaningful measurements, we calibrated our instrument by taking wavelength measurements of emission lines of mercury vapor. The emission lines of mercury vapor are well known so we compared the values we measured to the accepted values for the emission spectrum of mercury to come up with a calibration curve that related the values our instrument gave us to an actual wavelength.
Next, we measured the wavelength of hydrogen's spectral lines. After converting our measurements to actual wavelengths, we used Rydbergs's generalization of the Balmer equation to figure out the Rydberg constant for hydrogen. Our data and calculations showed that <math>R_\mathrm{H} = 1.10592*10^7 \pm 9.64*10^5\,\mathrm{m}^{-1}</math> in excelent agreement with the accepted value <math>10 967 758.341 \pm 0.001\,\mathrm{m}^{-1}</math>

Latest revision as of 19:28, 4 May 2009

This is my page for Junior Lab, Fall 2007. Links to my notebook and my main OWW page, where you can find contact info, below

My 307L lab notebook

My 307L lab notebook

Quick link to lab manual here

[http://www-hep.phys.unm.edu/~gold/phys307L/manual.pdf Quick link to lab manual here]

My main OWW user page

User:Tomas A. Mondragon

The Poisson fit accuracy tests

Poisson notebook

Formal Lab report

Formal Lab Report

Oscilloscope Lab Summary

Main notebook entry here.

see comment

Steven J. Koch 23:59, 2 October 2007 (EDT):Good work during this lab, Tomas. I think you've calculated the random uncertainty correctly (based on your email comments. So, the remaining question is: why is the accepted value so far outside of your uncertainty range??? This will be a puzzle for future experimenters in the 307L lab.

To get practice in using an oscilloscope, I adjusted the volts/div, time/div, and trigger settings on the oscilloscope to get the oscilloscope to display a ~200Hz sine wave, triangle wave, and square wave. Adjusting the time and voltage settings improved how well the wave form were displayed on screen, and adjusting the trigger appropriately made the waveform displayed on the screen steady.

To gain experience taking measurements with an oscilloscope, I measured the amplitudes of these waveforms using the grid on the scope's display, the scope's horizontal cursors, and the scope's peak-to-peak measurement function. I then used the scope's vertical cursors to measure the scope's characteristic AC coupling fall time. The voltage the oscilloscope measured under AC coupling after a DC voltage step up declined to 10% after about 32ms meaning the characteristic fall time was about 14ms

e/m ratio summary

This experiment worked better than I initially expected. I haven't done any proper number crunching yet, but the e/m ratio that Lorenzo and I measured seems to float around [math]\displaystyle{ 2.9\pm0.2\times 10^{11} \tfrac{\mbox{coulombs}}{\mbox{kilogram}} }[/math]

Further investigation can be done in how electrons lose energy to the helium in the bulb and how this effects radius.

Poisson Statistics summary

SJK 01:46, 22 October 2007 (CDT)

01:46, 22 October 2007 (CDT)
Outstanding work, Tomas! Your work in getting the experiment working was a huge help, and the care and time you spent on data analysis are very evident. Also, I am intrigued about the weird 27 count event you saw. If you have a chance, get together with Nik and Bradley to see how their multi-day experiment turned out.

notebook entries Physics307L:People/Mondragon/Notebook/070926 and Physics307L:People/Mondragon/Notebook/071003

Poisson distributions model count data of an experiment that count events during a dwell time that happen at random but do so at a definite average rate. (Nuclear decay, photon detection, etc.) Lorenzo Trujillo and I set up some gamma ray detection equipment inside of a lead shielded cavity and counted the events the equipment detected in 256 10ms, 20ms, 40ms, 80ms, 100ms, 200ms, 400ms, 800ms, 1s, and 10s time intervals. The data we collected fit Poisson distributions very well, and the average count numbers fit on a line on a average count number versus dwell time very well just like anything following a Poisson distribution should. We were counting, on average, 7.39 events per second. There was an interesting instance were we counted 27 events in a 200ms period, though. I wonder what caused that. Could it be some weird particle creation and annihilation event?

Planck's Constant

Physics307L:People/Mondragon/Notebook/071010 Physics307L:People/Mondragon/Notebook/071017

We calculated [math]\displaystyle{ h=3.77989*10^{-15}\pm 0.14521*10^{-15} \,eV*s }[/math] based on data collected from our experiment that took advantage of the photoelectric effect and the emmision spectrum of mercury vapor. The accepted value of [math]\displaystyle{ h =\,\,\, 6.626\ 068\ 96(33) \times 10^{-34}\ \mbox{J}\cdot\mbox{s} \,\,\, = \,\,\, 4.135\ 667\ 33(10) \times10^{-15}\ \mbox{eV}\cdot\mbox{s} }[/math] is within three standard deviations of my calculated value. Looks like a systematic error.

Speed of Light

Physics307L:People/Mondragon/Notebook/071024 Physics307L:People/Mondragon/Notebook/071031

Excitation Levels of Neon

Physics307L:People/Mondragon/Notebook/071107 Physics307L:People/Mondragon/Notebook/071114

Not much usefull data was gathered, probably the wiring was wrong.

I think this may be a graph of whats supposed to happen with reversed collector ring bias, bot its flipped around an only shows some nubs. No peaks.

Our resolution was 0.25 V. No peaks found.

Rydberg constant/Balmer Series summary

Notebook entry here

The Balmer series is a sequence of lines in hydrogen's absorption/emission spectrum in the optical range that follows the relationship

[math]\displaystyle{ \frac{1}{\lambda} = \frac{4}{B}\left(\frac{1}{2^2} - \frac{1}{n^2}\right) = R_\mathrm{H}\left(\frac{1}{2^2} - \frac{1}{n^2}\right), n=3,4,5,... }[/math].

This relation was found by Johann Balmer and was later generalized by Johannes Rydberg. RH is the Rydberg constant for hydrogen, [math]\displaystyle{ \lambda }[/math] is the observed wavelength of one of the lines, and n is an integer corresponding to that particular line as well as the principal quantum number of the excited electron state that produces the line. The Balmer lines are produced by absorption or emission of electromagnetic energy due to changes in the excitation level of the hydrogen atom between the first excited state and higher energy states.

To make meaningful measurements, we calibrated our instrument by taking wavelength measurements of emission lines of mercury vapor. The emission lines of mercury vapor are well known so we compared the values we measured to the accepted values for the emission spectrum of mercury to come up with a calibration curve that related the values our instrument gave us to an actual wavelength.

Next, we measured the wavelength of hydrogen's spectral lines. After converting our measurements to actual wavelengths, we used Rydbergs's generalization of the Balmer equation to figure out the Rydberg constant for hydrogen. Our data and calculations showed that [math]\displaystyle{ R_\mathrm{H} = 1.10592*10^7 \pm 9.64*10^5\,\mathrm{m}^{-1} }[/math] in excelent agreement with the accepted value [math]\displaystyle{ 10 967 758.341 \pm 0.001\,\mathrm{m}^{-1} }[/math]