Registry/Measurement kit/Preparation
From OpenWetWare
Description of the measurement kit components and methods of preparation. See also Registry/Measurement kit/Instructions for a description of how to use the kit to test a promoter or RBS.
Promoter Measurement Kit
Components
- psb3K3
- <bbpart>E0240</bbpart>
- TOP10 Chemically competent cells
Preparation
psb3K3
Primers for Preparatory PCR
- Need to fill in here.
Preparatory PCR
- The psb3K3 "backbone" plasmid is produced by PCR from a prepped psb3K3 template.
- A preparative PCR mix containing:
- 190 of PCR Supermix HIFI from Invitrogen
- 5uL of 3K3SuffixFWD primer
- 5uL of 3K3PrefixREV primer
- 0.5uL of template at ~40ng/uL
- Run PCR with the following conditions:
- 95C for 5 min
- 95C for 30 sec
- 55C for 30 sec
- 68C for 3min 20sec
- Goto 2 35 times
- 68C for 10 min
- 4C for eva
- Notes: I haven't really optimized the PCR conditions, but I find that using the Supermix is much more reliable than using the random endy lab stocks, fwiw.
PCR Cleanup
- PCR Cleanup on a 200uL preparative PCR mix should yield about 48uL of cleaned up DNA at a concentration of ~330-350ng/uL (16ug).
Restriction Digest
- Load 1ug of DNA into a 50ml digest (X/P)
- I use this protocol (except use buffer NEB3)
RBS Measurement Kit
Components
- psb3K3
- <bbpart>I13401</bbpart>
- TOP10 Chemically competent cells
Preparation
I13401
Miniprep
- Streak LB+Amp plate of I13401.1A2
- Innoculate 10ml of LB+Amp with a single colony from the plate, grow to saturation
- Miniprep the 10ml of culture
- Load the entire sample into a single miniprep column
- Elute with 50uL EB
- Measure the concentration of DNA in the sample (expected concentration?)
Digest
- Load 1ug of DNA into a 50ml digest (X/P)
- I use this protocol (except use buffer NEB3)
PCR Cleanup
- Expected conecntation
- On average we see ~65% yield between what went into the digest and what comes out of this cleanup step.
- So expected concentration will be ~22ng/uL in 30uL elution.
- I load 3uL into the ligation, so if you need to do more than 9 ligations then make up multiple digests (or include more DNA in the digest -- up to how much?)
Troubleshooting
- Described below are the tests we did to verify that the input parts to the measurement Kit are what we thought they are.