Registry of Standard Biological Parts/Bug reports

From OpenWetWare
Revision as of 10:25, 11 March 2006 by Reshma P. Shetty (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search
  1. Reshma 14:56, 16 Nov 2005 (EST): The registry appears to have some strange behavior when you try to enter a feature is whose starting coordinate is greater than its ending coordinate. It highlights two small stretches of sequence. (I was doing this in an effort to see if I could indicate features on the opposite strand.)
  2. Reshma 14:56, 16 Nov 2005 (EST): When you add a feature that is only 1 nucleotide long (like a mutation). It highlights 4 bases in the sequence pane instead of 1.
    • BC 15:23, 8 Dec 2005 (EST): The same bug seems to occur for other small features. It seems to highlight not just 4 bases extra but everyting up to the next "gap" in the sequence display, i.e. up to the next multiple of 10. Based on a small sample size (B0036 in E7103 and I7102 and R0085)
  3. Reshma 15:52, 16 Nov 2005 (EST): Somehow I am unable to edit the sequence of the part I just created (BBa_I50000). When I go to edit the sequence, it seems to just concatenate the sequence I type in rather than replacing the original sequence.