Cleaning Glass Beads:
- Wash beads in 70% ethanol twice
- Submerge beads in ethanol for ~3 min
- Use vacuum filter cap to remove ethanol
- Replace beads in beaker
- Wash beads once in ddH20
- Cover beaker with tinfoil, label and autoclave
- Label a second container and autoclave
- Put beads from beaker into the second container
- Bake beads overnight at 150 °C