Smolke:Protocols/Freezer stock management and database: Difference between revisions
From OpenWetWare
Jump to navigationJump to search
No edit summary |
|||
(7 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
''' | {{Smolke_Top}} | ||
*Position on cap insert (e.g., 1A1 for Box 1, position A1) | |||
===Freezer Stock Database=== | |||
The database is divided into two parts, the permanent archive and the working archive. | |||
*'''The permanent archive''' contains 1-4 vials of every cell line the lab has acquired or constructed. Whenever you create a new cell line that you feel other lab members might want to use, enter it into the permanent archive. | |||
**Every vial has a code that lists its box and its position within the box (e.g. 1A1 is the tube in position A1 in Box 1, 12H7 is the tube in position H7 in box 12). This code is used to organize the vials and reference them in the spreadsheet. Some positions are to be left empty to prevent the vials from becoming overcrowded in the freezer boxes. | |||
**No vial should be removed from the permanent archive unless there is no copy of that cell line anywhere else. In the event that you must thaw a vial, use it to immediately make more freezer stocks (about 9 vials). Add one of these to the permanent archive to replace the vial you took and the rest to create a new entry in the working archive. Be sure to update the spreadsheet both when you initially remove the vial and again when you replace it. | |||
*'''The working archive''' contains copies of cell lines from the permanent archive that are in frequent use. | |||
**The code for the working archive stocks lists the box and the row within the box (e.g. 5A is the label of every tube in row A in Box 5). A row of vials can share a code because every vial in a given row will be totally identical. | |||
**When you remove a vial from the working archive, you do not need to replace it immediately, but be sure to change the "Vials Remaining" field in the spreadsheet. You should also create and maintain personal freezer stocks of that cell line so that you need never take a vial of that cell line from the archive again. However, if you remove the last vial in a row, you must make a new batch of 8 vials to replenish the working archive (and update the spreadsheet accordingly), in addition to your set of personal stocks. | |||
**Under this system, each researcher should only ever need to remove one vial from the working archive for any given cell line. | |||
===Labeling for All Stocks=== | |||
All freezer stocks in the database must have a cap insert and a printed label on the side of the vial. To create labels, use the template document in the Tissue Culture folder on the lab server. Print the labels using the Endy printer. Be sure to load the blank label sheet in the proper orientation. | |||
The labels of all freezer stocks must include the following information: | |||
*Position on cap insert and label (e.g., 1A1 for Box 1, position A1) | |||
*Cell line name (e.g., CTLL-2 Parental) | *Cell line name (e.g., CTLL-2 Parental) | ||
*Passage number (for adherent cells) | *Passage number (for adherent cells) | ||
Line 6: | Line 20: | ||
*Initial and date | *Initial and date | ||
===Lymphocyte (CTLL-2, Jurkat, and NK-92) Stocks=== | |||
*Count cells with Trypan Blue | *Count cells with Trypan Blue | ||
*Determine number of stocks that can be made | *Determine number of stocks that can be made | ||
*Update freezer stock spreadsheet to determine stock position and print appropriate labels | *Update freezer stock spreadsheet to determine stock position and print appropriate labels | ||
*Harvest desired number of cells by spinning at 1400 rpm for | *Harvest desired number of cells by spinning at 1400 rpm for 5 min | ||
*Resuspend cells with heat-inactivated FBS + 10% DMSO to 10-20 million cells per ml | *Resuspend cells with heat-inactivated FBS + 10% DMSO to 10-20 million cells per ml | ||
*Aliquot cells into cryovials at 0.5 ml/vial (i.e., 5-10 million cells per vial) | *Aliquot cells into cryovials at 0.5 ml/vial (i.e., 5-10 million cells per vial) | ||
Line 17: | Line 32: | ||
*Transfer tubes to appropriate box and position in cryo container | *Transfer tubes to appropriate box and position in cryo container | ||
===HEK Stocks=== | |||
*Trypsinize, neutralize, and count cells with Trypan Blue | *Trypsinize, neutralize, and count cells with Trypan Blue | ||
*Determine number of stocks that can be made | *Determine number of stocks that can be made |
Latest revision as of 13:38, 7 December 2010
Freezer Stock DatabaseThe database is divided into two parts, the permanent archive and the working archive.
Labeling for All StocksAll freezer stocks in the database must have a cap insert and a printed label on the side of the vial. To create labels, use the template document in the Tissue Culture folder on the lab server. Print the labels using the Endy printer. Be sure to load the blank label sheet in the proper orientation. The labels of all freezer stocks must include the following information:
Lymphocyte (CTLL-2, Jurkat, and NK-92) Stocks
HEK Stocks
|