Line 24: | Line 24: | ||
*Size: I consider this ''massively'' oversized. In my experience, 50uL of PCR products (~3ug product) is more than sufficient for cloning. -Josh | *Size: I consider this ''massively'' oversized. In my experience, 50uL of PCR products (~3ug product) is more than sufficient for cloning. -Josh | ||
**I think this depends on what you're cloning. My inserts tend to be <150 bp, which | **I think this depends on what you're cloning. My inserts tend to be <150 bp, which means getting 3 ug of product requires significantly larger PCR volumes. Smaller inserts are also more difficult to purify without loss downstream, hence the large volume that I generally use. --YC | ||
*Polymerase: I use Pfu (>500bp) or PfuUltraII (>~3kb) for any lengthy PCR that I intend to clone. -Josh | *Polymerase: I use Pfu (>500bp) or PfuUltraII (>~3kb) for any lengthy PCR that I intend to clone. -Josh | ||
*Magnesium: I have never felt a need to vary my magnesium concentration on a reaction-by-reaction basis. So I mix my Taq buffer using a standard amount of magnesium (2mM, personally), and save an extra step. The magnesium concentration given above (0.16mM) seems ''way'' too low. -Josh | *Magnesium: I have never felt a need to vary my magnesium concentration on a reaction-by-reaction basis. So I mix my Taq buffer using a standard amount of magnesium (2mM, personally), and save an extra step. The magnesium concentration given above (0.16mM) seems ''way'' too low. -Josh |
Revision as of 13:55, 15 October 2009
Protocol
Notes
|