The BioBricks Foundation:Standards/Technical/Measurement: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
 
(3 intermediate revisions by one other user not shown)
Line 15: Line 15:
[[Image:Mfa0910100 BBF FACS.jpg|500px|thumb|left|FACS of promoter set at Lawrence Berkeley]]
[[Image:Mfa0910100 BBF FACS.jpg|500px|thumb|left|FACS of promoter set at Lawrence Berkeley]]
<br style="clear:both" />
<br style="clear:both" />
[[Image:DDM_promoter_chart.jpg|500px|thumb|left|FACS of promoter set at JHUSOM]]
[[Image:DDM_promoter_chart.jpg|500px|thumb|left|FACS measurements of promoter set at Johns Hopkins]]
<br style="clear:both" />
<br style="clear:both" />


Line 23: Line 23:
==Notebooks==
==Notebooks==
*[[Notebook:Jason R. Kelly/Projects/BBF Meas Standards]] - Jason's lab notebook.
*[[Notebook:Jason R. Kelly/Projects/BBF Meas Standards]] - Jason's lab notebook.
*[[User:Dileep_D._Monie/Notebook]] - Dileep's lab notebook
*[[User:Dileep_D._Monie/Notebook/BBF_Standards_Measurement]] - Dileep's lab notebook


==Notes==
==Notes==
Line 42: Line 42:
</biblio>
</biblio>


*[http://www.jstor.org/view/03697827/ap020024/02a00040/0 The Ohm is where the art is (Bruce Hunt)] - amazing history of standard setting in electrical engineering
*[http://www.jstor.org/stable/301998 The Ohm is where the art is (Bruce Hunt)] - amazing history of standard setting in electrical engineering
 
*[http://books.google.com/books?id=8M0LAAAAYAAJ Reports of the Committee on Electrical Standards (1873)] - The committee was responsible for determining "what would be the most convenient unit of resistance, and second what would be the best form and material for the standard representing that unit".

Latest revision as of 15:55, 3 November 2008

Goals of the BBF Measurement Working Group

  • We aim to submit the following standards for comment in advance of the June workshop:
    • the definition of a consensus relative fluorescence unit of measure - a 'Biobricks E. coli GFP fluorescence unit'
    • a standard method for measuring promoter strengths

Briefing on Measuring Promoters & RBSs

<html> <embed style="width:400px; height:326px;" id="VideoPlayback" type="application/x-shockwave-flash" src="http://video.google.com/googleplayer.swf?docId=3783852973289336417&hl=en" flashvars=""> </embed> </html>

  • Video from Jason Kelly introducing a standard measurement kit for characterizing BioBrick promoters and RBSs. (feel free to comment via talk page, blog, email, smoke signal, etc.)

Promoter measurement test

Plate reader & FACS measurements of the promoter set at MIT


FACS of promoter set at Lawrence Berkeley


FACS measurements of promoter set at Johns Hopkins


Protocols

Notebooks

Notes

Histogram of the MIT FACS data above, sorry there's no legend, but just wanted to show that the peaks aren't multimodal. The numbers reported as 'FACS' in the bar chart are the geometric means of these peaks reported relative to I20260 (dark blue).

References

  1. Dyer BW, Ferrer FA, Klinedinst DK, and Rodriguez R. A noncommercial dual luciferase enzyme assay system for reporter gene analysis. Anal Biochem. 2000 Jun 15;282(1):158-61. DOI:10.1006/abio.2000.4605 | PubMed ID:10860516 | HubMed [1]