*Measured .1065 g Adenosine and added it to 10 ml buffer to create approx 40 mM. 3 micro-liters 40mM | *Measured .1065 g Adenosine and added it to 10 ml buffer to create approx 40 mM adenosine solution. 3 micro-liters 40mM adenosine was added to 2996 micro-liters of buffer and 4 micro-liter of EHNA inhibitor to create a 40uM solution of adenosine.<br.> | ||
*In Dr.Hartings lab we added 30 ul of ADA after data was recorded 5 times. Data was recorded every 15 sec for 10 min.<br.> | *In Dr.Hartings lab we added 30 ul of ADA after data was recorded 5 times. Data was recorded every 15 sec for 10 min.<br.> | ||
* Dilutions were made with 50mM Phosphate buffer pH 74 <br.> | * Dilutions were made with 50mM Phosphate buffer pH 74 <br.> |
Revision as of 18:26, 19 October 2013
Biomaterials Design Lab | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Objective
Procedure
DataSpectra of ADA Conversion of Adenosine to Inosine
Concentration vs. Time for ADA Conversion of Adenosine to Inosine using an Inhibitor
|