User:Alicia Rasines Mazo/Notebook/CHEM-581 Experimental Chemistry I/2014/09/17: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
(fix raw html notebook nav)
 
(2 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 25: Line 25:
===Completing preparation of ionic liquid modified clay===
===Completing preparation of ionic liquid modified clay===
Continued from [http://openwetware.org/wiki/User:Alicia_Rasines_Mazo/Notebook/CHEM-581_Experimental_Chemistry_I/2014/09/10 Sept.10]
Continued from [http://openwetware.org/wiki/User:Alicia_Rasines_Mazo/Notebook/CHEM-581_Experimental_Chemistry_I/2014/09/10 Sept.10]
# Stir for 1 week.  
# Centrifuge: 4000 rpm, 30 min, 4°C
# Vacuum filter using 0.2uM nylon filter paper
#*Solution starting weight: 27.45 g
#*Collect supernatant first time
#*Wash with H<sub>2</sub>O
#*Wash with EtOH
#*Wash with H<sub>2</sub>O
#*Wash with EtOH
# Dry in oven at 90C overnight
# Dry in oven at 90C overnight
# Grind with a mortar and pestle.
# Store in a dessicator


====pXRD Measurements====
====pXRD Measurements====

Latest revision as of 00:18, 27 September 2017

Project name Main project page
Previous entry      Next entry

Tasks for 17 September

  • To run UV-Vis measurements of MG left in solution (not absorbed by PVA polymer film).
  • To finish synthesis of 10 % PVA-exfoliated clay
  • To finish preparation of ionic liquid modified clays
  • To run pXRD

UV-Vis analysis of MG leftover solutions

  • Dilutions of some of the MG solutions were made in order to be able to use the spectrometer
    • Diluted 200 ppm 100 times by adding 100μL to a 10 mL volumetric flask. This was done for the polymer film-containing solutions.
  • Also diluted 80 ppm 50 times by adding 200μL to a 10 mL volumetric flask.
  • Diluted 200 ppm and 80 ppm MG 100 and 50 times respectively. Then ran UV Vis measurements to measure absorbance of MG dye coated onto vial glass.

Completing synthesis of 10% PVA-exfoliated clay

Continued from Sept. 12

  • Placed in sodium sulfate solution, followed by 1% HCl solution and finally in Sodium Bicarbonate

Completing preparation of ionic liquid modified clay

Continued from Sept.10

  1. Centrifuge: 4000 rpm, 30 min, 4°C
    • Solution starting weight: 27.45 g
    • Collect supernatant first time
    • Wash with H2O
    • Wash with EtOH
    • Wash with H2O
    • Wash with EtOH
  2. Dry in oven at 90C overnight

pXRD Measurements

  • Sample prepped on Sept. 12, to be analysed on Sept. 19.
    1. Hartings- NaMT
    2. Madeleine and Alicia- 8 ppm
    3. James's group- 2 ppm
    4. James's group- PVA
    5. Eleni's group- 80 ppm
    6. Andrew's group- 200 ppm
  • Instrument parameters on Dr Hartings OWW