User:Andy Maloney/Surface passivation effects on kinesin and microtubules

From OpenWetWare
Jump to navigationJump to search

Purpose

This page describes the experiment where I investigated gliding speed variations of microtubules using different surface passivation schemes using the gliding motility assay.

This is the second chapter in my completely open notebook science dissertation. If you would like to post questions, comments, or concerns, please join the wiki and post comments to the talk page. If you do not want to join the wiki and would still like to comment, feel free to email me.


Introduction

Figure 1: Image of our mascot "Kiney" at the microscope where I perform experiments. The plush doll form of Kiney was made by Child's Own Studios.

Both kinesin and microtubules are vital components of eukaryotic cells. Kinesin is used as a vehicle to shuttle items from one part of the cell to another and microtubules are the roads that kinesin travel on. Kinesin walks along microtubules in one direction and does so by converting chemical energy, in the form of ATP hydrolysis, to linear motion (Carter 2005, Vale 1997, Hua 1997, Vale 1985, Goldstein 1999). Observations of this system are typically carried out in two manners: the gliding motility assay or with an optical trap (Block 1990, Yildez 2004, Gelles 1988). The gliding motility assay (Böhm 1997, Böhm 2000, Böhm Stracke & Unger 2000) is the experimental procedure of interest for this study and a description on how to prepare a gliding motility assay can be found in Chapter 1.

These studies show that the type of casein used in an assay affects the kinesin and microtubule system. One way to measure this affect is to observe the speed at which microtubules glide. This study aims to show that there are subtle differences in the speeds at which microtubules will glide at and I will offer some of my own ideas as to why I think these differences exist.

Methods and materials

In this section, I will discuss the technological hurdles required to obtain stable data and the subtle differences in the generic gliding motility assay described in Chapter 1.

Temperature stabilization

Figure 2: Graph showing three gliding motility experiments using different passivation schemes, alpha casein, beta casein and whole casein. Note that each individual trace continuously increases in speed over time.

Temperature stabilization is crucial for observing stable speeds. Without it, I observed microtubule gliding speeds increase over time. Figure 2 shows data that did not use a temperature stabilized objective and shows a sharp initial increase in speed which, over time would taper but never level off. There are three different assays in the graph, one each of: alpha casein, beta casein and whole casein. A description of the different types of caseins will be given below, briefly they are the constituents of whole casein described in Chapter 1. I initially thought that I observed the goal of this study; which was to observe speed changes dependent on the type of passivation used. However, what I observed was that kinesin is a very sensitive temperature probe.

I presented Figure 2 at the Biophysical Society Meeting 2010 where Stefan Diez suggested that the increase in speed over time was due to a temperature effect. I did not initially understand his comment because there was nothing attached to the microscope that could be heating the sample. So, I didn't really do anything about it. I presented more of the same data showing speed changes due to water isotopes and osmolytes at a conference in Santa Fe later that year (Maloney 2010). Erik Schaeffer attended the conference and he again told me that there was a temperature issue and that was why I saw the speed increase over time. He described to me the microscope setup used in his lab which stabilized the temperature of the objective with millikelvin precision. He told me that with this setup, he could tell rather precisely when and if a graduate student in his lab turned on the computer monitor near the microscope. This story blew me away and I of course didn't think it possible but, it most certainly is true as I found out with my experiments. If a computer monitor not even attached to the microscope could register a temperature increase on the objective, then there was a highly probable possibility that my microscope was heating up due to the mercury lamp.

Figure 3: Temperature of the microscope objective with no temperature stabilization and the mercury lamp on shining through the objective. The black curve is when the lamp was on and the red was when it was switched off. Figure 4: Graph showing the three experiments from Figure 3 plotted with respect to the time of day they were performed at.

The temperature of the entire microscope does increase over time due to having the mercury lamp on. Figure 3 shows the temperature increase of the objective due to having the mercury lamp on and shining through it. The temperature of the objective was taken at the top, near where the sample would be and no oil was used on the objective. As can be clearly seen, the objective does reach a stable temperature, albeit 5.5 hours after turning the lamp on. This is not ideal for experiments as one would have to wait 5.5 hours before being able to take measurements. This graph does not show the effect of placing a microscope slide on the objective either. Adding a slide at room temperature will cause the temperature of the objective to decrease as can be seen in Figure 5.

Returning to the data taken in Figure 2, I decided to re-plot the data against absolute time, i.e. from the seconds measured since 1904. Thankfully I took all the data in Figure 2 on the same day and when plotted with their time stamps appropriately zeroed from the first image taken, Figure 4, one can clearly see that there is an overall increase in speed as time goes on. As a bonus, one can also see that over the time the slide is on the objective, the speeds increase. This was due to the fact that the slides were at room temperature and they heated up when on the objective. A plot showing the effect of temperature on the objective for turning the heating element on and off, and adding oil and removing and replacing a slide on the objective can be seen in Figure 5.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Movie 1: Showing the focus drift due to temperature instabilities. When the overall image becomes brighter, the focus is drifting.

This finding I felt was unfortunate because it basically said that the large differences in gliding speeds was solely due to temperature effects and not on the chemistry of passivation. Nonetheless, I took this opportunity to build a similar system to what Erik Schaeffer used in his lab to stabilize the temperature of the microscope objective (Mahamdeh 2009). As can be seen in Figure 5, with a stable temperature, speed measurements can be recorded with as little as ±4 nm/s errors. This is a feat all to itself since average speeds in the literature can quote errors as large as 50 - 100 nm/s (Böhm 1997). Figure 6 also shows the large increase in speed observed in my earlier experiments for early times, except now, the data levels off. Figure 6 shows quite nicely that without temperature stabilization, speed measurements would not be stable. As an added bonus, Movie 1 shows that when there was no temperature stabilization on the objective, the focus would change periodically. This required constant adjustments to the focus of the objective. The movie looses focus when the overall image gets brighter. This is due to the objective collecting more light from the fluorescent microtubules in solution and not at the surface of the slide where the kinesin is adhered to.

A detailed description of the build can be found in an Instructables post. This design can maintain a temperature to ±0.1°C. There are very few studies that indicate whether or not observation of the gliding motility assay was done with temperature stabilization or not. It has been shown that temperature does play a crucial role in obtaining stable data (Böhm 2000, Böhm Stracke & Unger 2000) in a few studies, as well as, the ones I have done.

Figure 5: Temperature of the microscope objective with temperature stabilization. The initial spikes are due to turning the stabilization electronics on and off. The smaller spikes at later times are when a slide is removed from the objective and replaced with a new slide at room temperature. Figure 6: Graph showing gliding motility speed values after temperature stabilization of the objective. Alpha casein was used as the surface passivator.


Materials

I like to think of the preparation for all the solutions used in an assay as my mise en place. And, just like no one would ever touch a fellow cook's mise en place in a restaurant, no one but me was allowed to use my solutions. These rules were set in place partly due to how finicky these assays are and how I've learned that keeping a tight control on my solutions allows me to quickly replace chemicals when an assay has gone awry.

I have already spoken about several of the necessary tools used for this assay in Chapter 1. Below, I will link to the tools that do not change for this assay and go into greater detail about those that do. Those items in the list that do not have have links will be described below.


Passivation solutions

This experiment used the different bovine casein constituents to investigate speed variations of microtubules in the gliding motility assay. In the temperature stabilization section of this chapter, my initial experiments saw huge differences in speed with the different caseins used. As was already mentioned above, the large speed variations were due to temperature effects and not due to the passivation chemicals. Once I stabilized the temperature of my objective, I continued to investigate if there were any variations in speed due to surface passivation. It turns out that there was a difference in speed measurements due to surface passivation, albeit a more subtle difference than what I saw initially without temperature stabilization.

To begin this experiment, I purchased the following caseins all from bovine milk.

Each casein component was reconstituted in PEM under constant stirring. I will outline below the different solutions that were prepared for this experiment giving the naming convention for each solution in the subheading.

W-PEM

For a detailed description of how to make W-PEM, please see Chapter 1.

α-PEM

The subscript "s" attached to alpha casein means "sensitive" since the alpha caseins are the first caseins to be removed from solution by adding over 4 mM calcium. αs1-casein comprises approximately 37% of whole bovine casein while αs2-casein comprises only 10% (Fox 1998 Ch. 4).

Alpha PEM has 1.0 mg/mL α-casein in PEM. Dissolving α-casein in PEM required approximately 60-80 minutes of constant stirring at room temperature. The procedure I followed to make α-PEM is as follows.

  1. Weigh out 25 mg of α-casein.
  2. Add the 25 mg of α-casein to 25 mL of PEM.
  3. Stir for approximately 60-80 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

α-PEM will last for 6 months stored at 4°C. No additional filtering was done on the α-PEM solution.

β-PEM

β-casein comprises approximately 35% of the protein in whole bovine casein. It takes approximately 400 mM calcium to remove it from a solution of skim milk (Fox 1998 Ch. 4).

β-PEM has 1.0 mg/mL β-casein in PEM. The procedure for making β-PEM is very similar to how I made α-PEM except for the length of time required to mix.

  1. Weigh out 25 mg of β-casein.
  2. Add the 25 mg of β-casein to 25 mL of PEM.
  3. Stir for approximately 30-40 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

β-PEM will last for 6 months stored at 4°C. No additional filtering was done on the β-PEM solution.

κ-PEM

κ-casein is structurally very different from α and β casein. Kappa casein is a glycoprotein and was depicted in Chapter 1's whole casein micelle's as its "hairs". Kappa casein is thought to stabilize the casein micelle and it is unaffected by calcium concentration. It can even help to stabilize alpha and beta caseins from calcium precipitation (Fox 1998 Ch. 4).

κ-PEM has 1.0 mg/mL κ-casein in PEM. The procedure for making κ-PEM is very similar to how I made κ-PEM except for the length of time required to mix.

  1. Weigh out 25 mg of κ-casein.
  2. Add the 25 mg of κ-casein to 25 mL of PEM.
  3. Stir for approximately 15-20 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

κ-PEM will last for 6 months stored at 4°C. No additional filtering was done on the κ-PEM solution.

M-PEM

A mixed variety of whole casein was also prepared. I called this solution M-PEM. From the stated amounts of the individual casein components, I mixed a "whole" casein type solution using α-PEM, β-PEM, and κ-PEM. I decided to do this because I wanted to see if I could artificially reproduce the results obtained from W-PEM.

Since all the components of casein were already in solutions of PEM, I just mixed them in a vial to obtain M-PEM.

  • 49% α-casein or 980 μL of α-PEM.
  • 37% β-casein or 740 μL of β-PEM.
  • 14% κ-casein or 280 μL of κ-PEM.

M-PEM will last for 6 months stored at 4°C. No additional filtering was done on the M-PEM solution.

I did not investigate the solubility of the caseins in a solution of PEM. Casein solubility is a complicated function of other casein constituents in solution (Zittle 1961, 1963), temperature (Payensa 1963, O’Connell 2003, Leclerc 1997), genetic variants (Thompson 1969), ionic strength and types of salts in solution (Thompson 1969), calcium ion concentration (Zittle 1961, Zittle 1963, Thompson 1969), and pH (Bingham 1971). Casein solubility measurements were not performed in this study.

Experiment and data analysis

The speed at which microtubules glide at in the motility assay depends on a number of factors one of which, is the pH of the solution. In my PEM solution, the amount of NaOH is approximate since each solution of PEM is pH-ed to 6.89. Böhm (Böhm Stracke & Unger 2000) shows that gliding speed is affected by both the pH and the ionic strength of the solution the motors are in. In an effort to reduce as many variables as possible for speed measurements, I chose to maintain the pH of the PEM buffers at exactly 6.89 and vary the amount of NaOH necessary to achieve this pH.

For a complete description of the gliding motility assay, please see Chapter 1. Briefly, polymerization was carried out in a Thermo PCR Sprint thermocycler held constant at 37˚C and incubated for 30 minutes using 1 µL of the 29% rhodamine-labeled and 71% unlabeled tubulin. After 30 minutes, the microtubules were fixed and diluted by 200x by adding 199 µL of PEM-T. Polymerized microtubules were stored at room temperature and protected from ambient light until used in a motility assay. Storing polymerized microtubules at 4˚C will cause rapid depolymerization (Shelanski 1973).

Gliding motility assay

Experiments followed the same recipe outlined in Chapter 1. The steps taken for this experiment were as follows.

  1. Prepared a flow cell.
  2. Incubated the flow cell with 1.0 mg/mL of the various caseins in PEM for 10 minutes.
  3. During the 10 minute incubation, kinesin was diluted in 0.5 mg/mL of the same casein in PEM used in Step 2, plus 1 mM ATP. The final concentration of kinesin used in these experiments was 27.5 μg/mL.
  4. After 10 minutes, kinesin was flowed into the flow cell by fluid exchange. This was then allowed to sit for 5 minutes.
  5. During the various incubation steps, a new motility solution was prepared for each assay. The different motility assays consisted of:
  6. After the 5 minute incubation with kinesin, the motility solution was introduced to the flow cell by fluid exchange.
  7. The flow cell was then sealed with nail polish.

In order to not dilute the Taxol used to stabilize microtubules, it is added in the motility solution at the same concentration used in PEM-T. This is the same reason why 1 mM ATP is added to the motility solution. I did not want to dilute the amount of ATP the kinesin is stored in. The kinesin home page and Verma et. al. (Kinesin, Verma 2008), suggest that adding casein to the motility solution enhances the chances of a gliding motility assay to work properly. I observed that adding casein to the motility solution causes microtubules to undergo non ideal motility, i.e. they move in tight circles and end up wrapping around themselves such that the microtubules look like squiggles and are untrackable. In order to prevent such behavior, I did not include casein in the motility solution.

After sealing the flow cell, the slide was immediately placed on the microscope for observation. Data was taken at 5 frames per second with a single exposure time for each frame of 100 ms. The camera software was set to take a total of 600 images for one region of interest (ROI) and have an EMCCD gain of 150. The time to capture 600 frames was approximately 2 minutes of total exposure for one ROI. After the camera had captured 600 frames, I moved the sample on the microscope. I moved the flow cell around because I wanted to get a broad sample of speed measurements from it. One reason for doing this is to try and not continuously sample only one area of kinesin coverage (Hunt 1994). showed that microtubules would slow down against viscous loads if the kinesin concentration was low. My assays never used small concentrations of kinesin but, to ensure that I had a sampling of speed that did not have to take into account kinesin coverage, I moved the sample around. Each slide was repositioned on the microscope for a total of 15 time giving me 15 ROIs to analyze data from.

Data analysis

Microtubules were then tracked using a custom LabVIEW tracking application thanks to Larry Herskowitz. The tracking software used image segmentation algorithms to identify microtubule ends via pattern matching. The software did not track microtubules that that had fewer than 100 consecutive images. This lower bound of images was found through experiment to give reliable data. Microtubules that could be tracked with fewer images did not consistently give high fidelity data and thus a lower bound for images was set. The software was unable to track microtubules that had a segmented area less than 55 pixels due to the pattern matching algorithms used. This put a lower bound on the length of trackable microtubules to be around 2 μm. Finally, tracking of microtubules stopped if the microtubule crossed other microtubules or if it came too close to the edges of the ROI.

Once tracking was complete, the X and Y pixel values for the ends of microtubules were then analyzed with another custom LabVIEW analysis program again written by Larry Herskowitz. This program calculated the speeds at which microtubules were moving at by subtracting the pixel values of consecutive tracked microtubule images and dividing by the time between frames.

[math]\displaystyle{ s=166.7\left(\frac{nm}{s}\right)\times\frac{\sqrt{(x_{n+1}-x_n)^2+(y_{n+1}-y_n)^2}}{t_{n+1}-t_n} }[/math]

These values are plotted in Figure 8 as the blue markers. As one can see, there is a lot of noise in these raw measurements. I believe that the cause is because microtubule ends are never permanently attached to the kinesin surface and thus undergo transient Brownian motion. To alleviate this noise, a sliding Gaussian window of 2 seconds was used to smooth the data. This newly smoothed data is depicted as the black curve in Figure 8. Boundary effects due to the finite sample size are quite evident in the graph. There are a lot of techniques that try to compensate for these edge effects, however, we as a group decided to not take them into consideration. Instead, we decided to remove 5 seconds worth of points from the beginning and end of the data set. This completely removed all the edge effects due to smoothing.

Figure 8: Data analysis. Blue markers are X and Y data points tracked by the tracking program. They have been converted to speed values. The black curve is the smoothed data using a Gaussian window with a width of 2 seconds. The red curve is the data that is then analyzed by the KDE algorithm.
Figure 9: KDE of a single microtubule gliding speed using alpha casein passivation.

Automated tracking provided the x and y position with subpixel accuracy of the microtubule ends for each frame that was tracked, see Figure 8. These time series data (blue markers) were smoothed (black line) with a sliding Gaussian window with a standard deviation of 2 seconds. Smoothed data points that were within 5 seconds of the beginning or end of the tracks were discarded (red line) in order to eliminate window boundary effects on the smoothed data. Smoothing the position versus time data was necessary since the microtubule ends are never permanently attached to the kinesin surface and thus undergo transient Brownian motion. After smoothing and truncating, the instantaneous speed was calculated as the distance per time between consecutive frames.

Kernel density estimation (KDE) (Silverman 1968) was then done on all the individual microtubules. Making a KDE is very similar to making a histogram of the speed data. Except that the KDE method applies a Gaussian kernel around every point instead of placing a data point in a bin. The Gaussians are then summed together to give a smooth representation of what the microtubule speed is. Figure 9 shows the KDE of the microtubule data in Figure 8. The bandwidth used in this kernel was 20 nm/s. As you can see in Figure 8, The smoothed red line data is not completely flat. This is because the microtubule does not travel at the same speed all the time. It can pause, stop completely, or even slow down. Using the KDE method allows one to see these subtle differences in speeds and is quite evident in Figure 9. My present study was to look at the average or most probable speeds a microtubule will travel at using different passivation schemes. This is why I took the most likely speed a single microtubule traveled at and used that speed for the next step in the analysis.

Speed versus time data for all the microtubules in an individual region of interest (ROI) were then concatenated together and the most likely speed for a ROI was extracted using the KDE method with a Gaussian kernel of width 50 nm/s. Using the KDE method instead of a simple mean reduces the sensitivity to microtubule pausing or stalling, which was evident in many assays. We used a large kernel width to reduce sensitivity to possible speed changes due to number of kinesin motors or other causes (Gagliano 2010). The most likely speeds for individual regions were then plotted versus time to determine when the slide had reached thermal equilibrium with the objective, see Figure 6. The initial 5 data points were removed for all data sets indicating that it took about 10 minutes for the slide to reach a stable temperature. Each assay; alpha, beta, kappa, whole, and mixed casein was repeated 3 separate times on different days and with different kinesin aliquots. When possible, the mean and standard error of the mean was computed for the three data points for a given assay time.

Results and discussion

Results

Data was taken at 33.1 ± 0.1°C as measured from the top thermistor on the objective. This temperature is well above the temperature the objective would reach due to long-term heating, see Figure 3, from the Hg lamp and was found to give consistent data, Figure 6. I observed that the closer the observation was to the boundaries of the flow cell, the slower the microtubule gliding speed was and, that the propensity for depolymerization increased near the boundaries. In order to obtain consistent data and prevent depolymerization of the microtubules, gliding assays were observed in the center of the flow cell channel, except where otherwise noted. All images have had dead pixels removed by an interpolation function and have been false colored using ImageJ’s green fire blue LUT using a custom LabVIEW 7.1 application.

Bovine alpha casein (a mixture of αs1 37% and αs2 10%) constitutes approximately 47% of whole bovine casein (Fox 1998 Ch. 4). This passivation was capable of supporting small microtubules and longer ones as can be seen in Figure 10. When using alpha casein, the gliding motility assay worked every time except when the kinesin or antifade system lost its effectiveness for maintaining a gliding assay. Movie 2 shows a typical gliding assay using alpha casein as the surface passivator.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/UnRTr1FUdtY?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/UnRTr1FUdtY?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 10: Typical image from a gliding motility assay using alpha casein as the surface passivator. Movie 2: Typical movie from a gliding motility assay using alpha casein as the surface passivator.

Bovine beta casein comprises approximately 35% of whole casein and visible precipitates took less time to dissolve in PEM as compared to alpha casein. Figure 11 shows that beta casein as a surface passivator was not ideal. It did not support smaller microtubules and did not in general have very many motile microtubules in any assay. The microtubules that were motile, were typically quite long. Beta casein also caused the microtubule’s minus and positive ends to detach from the kinesin surface while undergoing motility more often than the other passivation schemes. This caused errors in the tracking and thus did not give consistent data. This is unfortunate as it can be purified to better than 98% making this component of whole casein the purest commercially available. Another interesting phenomenon observed when using beta casein was that motile microtubules were not found in the center of the channel for the flow cell. Motile microtubules were observed, but they were always found off center to the flow cell channel. I am not sure of the reason for this but, it may depend on kinesin or casein concentration. I did not vary the input kinesin or casein concentration for these studies.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 11: Typical image from a gliding motility assay using beta casein as the surface passivator. Movie 3: Typical movie from a gliding motility assay using beta casein as the surface passivator.

Kappa casein, compared to alpha and beta, is structurally very different. It is a glycoprotein and is thought to stabilize the casein micelle (Fox 1998 Ch. 4, Walstra 1999, Phadungath 2005) by sterically hindering the aggregation of too many casein sub-micelles. It did not support motility in a very consistent manner as can be seen from Figure 12. As was the case for beta casein, kappa casein did not support motility in the center of the channel of the flow cell. Stuck microtubules were found near the center of the flow cell and near the tape. However, between the boundaries of the flow cells and away from the center of it, there was motility. In the areas that motility existed, kappa casein was able to support motility of long and short microtubules with the exception of extremely short microtubules found to move only in the alpha or whole casein assays. The very short microtubules either remained stuck to the surface or exhibited motility for a very short period of time before going into solution. Kappa casein did a remarkable job of adhering microtubules to the slide much like how poly-L-lysine is used to fix microtubules on a slide (Vater 1995).

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 12: Typical image from a gliding motility assay using kappa casein as the surface passivator. Movie 4: Typical movie from a gliding motility assay using kappa casein as the surface passivator.

Whole bovine casein is the passivator of choice when doing gliding motility experiments. We found that whole bovine casein worked remarkably well for sustaining motility. Similar to the alpha casein passivation, whole casein worked every single time and gave consistent data. It was only when we deemed either the kinesin or the antifade system to have lost its effectiveness at maintaining microtubule gliding that the assay did not work. Of the 5 types of bovine casein solutions tested, whole casein required heat in order for visible precipitate to completely dissolve in was the most difficult to get into a solution of PEM. See the supplemental information for a more thorough discussion of how we dissolve whole casein in PEM. We did not observe any adverse affects to motility by heating whole casein. Whole casein supported long and short microtubule motility as shown in Figure 1 E.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 12: Typical image from a gliding motility assay using whole casein as the surface passivator. Movie 5: Typical movie from a gliding motility assay using whole casein as the surface passivator.

Mixing whole casein from the individual constituents of alpha, beta, and kappa was also used as a surface passivator. The mixed whole casein consisted of 49% alpha casein, 37% beta casein and, 14% kappa casein which is very similar to what Fox and McSweeney state as the casein components of bovine milk (Fox 1998 Ch. 4). Mixing it was easy since each component was already in a PEM solution. The behavior of the mixed bovine whole casein was indistinguishable from the purchased whole casein or the alpha casein passivation. The number of microtubules and the varying lengths undergoing motility in the mixed casein passivation was very similar to those of the whole casein passivation as well.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 12: Typical image from a gliding motility assay using mixed casein as the surface passivator. Movie 6: Typical movie from a gliding motility assay using mixed casein as the surface passivator.

Figure 13 shows the mean speed measurements for 15 different regions of interest for the alpha, beta, whole and mixed casein assays. Each region of interest is the mean and SEM from three separate samples. The passivator that gave the most consistent speed was alpha casein. The mean speed and SEM from our alpha casein measurement was 949 ± 4 nm/s. Purchased whole casein and mixed casein performed remarkably similarly and displayed average speed values of 966 ± 7 nm/s and 966 ± 7 nm/s respectively. Bovine beta casein performed poorly in comparison to alpha, whole, or mixed caseins and we measured the mean speed to be 870 ± 30 nm/s. Figure 14 shows the observed speeds for kappa casein passivation. Since there were so many areas where no motility was observed in this assay, it was difficult to determine a mean speed measurement for each ROI as was done in Figure 13. However, it does appear that when motile, the speeds were around 870-880 nm/s with kappa casein as the surface passivator. This was similar to how beta casein performed.

Figure 13: Black circles are alpha casein passivation, red squares are beta casein passivation, green right side up triangles are whole casein passivation, and blue upside down triangles are mixed casein passivation. Error bars are the standard error of the mean for each region in the flow cell where data was taken. Alpha casein has the most consistent average speed measurements at 949 ± 4 nm/s. Whole casein and mixed casein averaged to 966 ± 7 nm/s and 966 ± 6 nm/s respectively. And, beta casein averaged to 870 ± 30 nm/s. Errors in the average speed are the standard deviation from the average. Figure 14: Green squares, red circles, and blue triangles represent 3 different assays. As the figure shows, kappa casein is not the ideal surface passivator. There are many regions in the flow cell where no motility exists at all and other areas where motility can give quasi consistent results. Albeit at much slower speeds than is reported from alpha, whole or mixed casein passivations. The open black circles show a characteristic alpha casein assay for comparison. Note that the initial increase in speed is due to the slide coming to thermal equilibrium with the objective.
Figure 15: Filled blue bars are length calculations for the alpha casein passivation, filled green bars are for the beta casein passivation, filled red bars are for the kappa casein passivation, unfilled black bars are for the mixed casein passivation, and unfilled purple bars are for the whole casein passivation. Length measurements were performed only on tracked microtubules and are estimations from computing the Convex Hull perimeter on eroded images of microtubules.

Figure 15 shows a histogram of microtubule lengths. To obtain lengths, an erosion algorithm was used on binary images of only the microtubules that were tracked. The erosion algorithm comes as a standard function in LabVIEW 7.1. The “skeleton” algorithm, as it is called in LabVIEW, is not optimized for measuring microtubule lengths and tended to overestimate them. Because of this, another algorithm was used on the “skeletonized” microtubules, namely a Convex Hull perimeter calculation, also found in the LabVIEW library of functions. Dividing the Convex Hull perimeter by 2 gave lengths that consistently fell in between manual measurements done my myself and Koch. As can be seen in the figure, alpha casein (filled blue bars), whole casein (empty purple line bars) and mixed casein (empty black line bars) all were able to sustain motility with smaller microtubules 2 - 6 µm range. Beta casein (filled green bars) had significantly fewer microtubules that were tracked, however, those that were tended to be longer than the ones tracked in the alpha casein assay. Kappa casein (filled red bars) show that there were many more trackable microtubules than beta casein and significantly fewer than alpha casein. The smallest trackable microtubules using our algorithm are not smaller than 2 µm. Figure 2 shows that while in comparison to the other lengths, there are relatively few 2 µm microtubules in any of the assays, kappa casein had no microtubules that fell in the 2 - 3 µm range. There is, however, a larger number of kappa casein microtubules that were in the 20 - 21 µm range as compared to the other assays. Length measurements using this method are not optimized for precision. This method does, however, give a simple way to see the relative size distribution differences in the assays.

Discussion

It would appear that the more difficult it was to dissolve casein, the better it worked as a surface passivator. This may be a coincidence, or it may relate to the manner in which casein adsorbs to the glass. Whole casein was by far the most difficult to dissolve visible precipitate into PEM without heating. Alpha casein came in second, beta third and kappa fourth in terms of the time to dissolve completely in PEM at room temperature. Whole casein is approximately 50% alpha casein and seeing how well alpha casein performed as a surface passivator, it was not surprising to find that whole casein also performed well. The differences in measured speeds between alpha and whole casein could be a result of how kinesin is supported by the different caseins, or it could be due to differences in surface-coverage for passivation by the casein. It has been shown that using substrates of differing hydrophilicity with whole casein passivation affects the activity of kinesin (Huang 2005). This is a very interesting result and could be an indication that kinesin likes to adsorb to the casein and not the substrate. And, the hydrophobicity of the surface could influence how casein adheres to it ultimately affecting the gliding motility assay.

Purchased whole and mixed whole casein were practically indistinguishable. They performed almost identically and had the same measured speeds. Mixed whole casein has an upper bound of 20% impurities in it. This amount is very similar to the amount of impurities alpha casein has in it yet, mixed whole casein performed exactly how purchased whole casein did. This similarity between mixed and purchased whole casein suggests that the speed difference between alpha and whole casein is not due to impurities but rather that it is due to how kinesin is supported by the casein micelles or, how casein interacts with the glass. To elucidate the effects, it would be prudent to measure the speeds for the various caseins as a function of casein and kinesin concentrations during incubation. I have not performed these experiments.

Beta casein would have been the most ideal protein to use as the surface passivator since it can be purified to greater than 98% purity. Higher protein purity is advantageous for systematically producing devices that use kinesin and microtubules as sensors. However, beta casein did not perform very well. It had the least number of motile microtubules to track, it was not very reliable, and had a large distribution in speeds. It is possible, though, that varying other parameters such as kinesin concentration, or beta casein concentration could restore reliable motility. Again, these are future experiments.

Kappa casein would be an attractive surface passivator just for its ease in dissolving in PEM. However, where motility exists in the flow cell is not consistent and it never occurs in the center of the channel where I have observed the most consistent speed measurements from other assays. With kappa casein, many long and stable microtubules permanently stuck to the surface. I am not sure if the sticking is caused from kinesin attaching to microtubules and then somehow being impeded from moving or, if there is actually no kinesin on the kappa casein surface and the microtubules are just attracted to the kappa casein or glass. Remember that kappa caseins are glycoproteins are are structurally very different than the other casein constituents.

Of the five types of bovine casein used to observe the gliding motility assay, alpha casein performed very well. It is the easiest of the three commercially available bovine casein constituents to dissolve in PEM and can be purchased at 70% purity. Most likely, the 30% contaminants are from other casein components. It performed well every time an assay was prepared and worked just as well as mixed and purchased whole casein.

Conclusion

There are a wide variety of surface passivation strategies in the literature. Even for use with kinesin in the gliding motility assays there exists choices for the casein to use as the passivator. Bovine alpha casein was the most reliable passivator when following the most typical gliding assay protocol found in Chapter 1. This is why I have chosen it to be used for my following studies using isotopes of water in the gliding motility assay.

Future work

There are a great number of experiments that could be done to further this line of research. For instance, varying the amount of kinesin used in each assay could illuminate more characteristics of how kinesin interacts with the surface passivation. Also, varying the casein constituent concentration used to passivate the surface could bring to light the possibility that either beta or kappa casein is a better surface passivator than alpha casein. And finally, since the individual constituents of bovine casein can be purchased separately, one can devise experiments that uses engineered "whole casein" as the surface passivation. One could even use dephosphorylated alpha or beta casein as components to the engineered surface passivation.

References

  • Fox, P, & McSweeney, P (1998). Chapter 9: Heat-induced changes in milk. Dairy chemistry and biochemistry (1st ed., pp. 347-378). London: Blackie Academic & Professional.
  • O’Connell, J. E., Grinberg, V. Y., & Kruif, C. G. de. (2003). Association behavior of β-casein. Journal of Colloid and Interface Science, 258(1), 33-39. doi: 10.1016/S0021-9797(02)00066-8.
  • Vale, RD, & Fletterick, RJ (1997). The design plan of kinesin motors. Annual review of cell and developmental biology, 13, 745-77. doi: 10.1146/annurev.cellbio.13.1.745.
  • Yildiz, A, Tomishige, M, Vale, RD, & Selvin, PR (2004). Kinesin walks hand-over-hand. Science (New York, N.Y.), 303(5658), 676-8. doi: 10.1126/science.1093753.


Notebook entries

All of my raw observations, raw data taking, and silly ramblings are contained in my notebook entries. They are the unedited versions of this page.