|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 8: | Line 8: | ||
==Objectives== | ==Objectives== | ||
# Perform | # Perform 2nd Agar Disc Diffusion Assay | ||
Line 63: | Line 63: | ||
# Thaw Ecoli frozen sample (from basement storeroom, retrieved with Dr. Hartings) for 30 min over ice | # Thaw Ecoli frozen sample (from basement storeroom, retrieved with Dr. Hartings) for 30 min over ice | ||
##Plate 100ul sample of thawed Ecoli solution onto mueller hinton agar plates by first pipetting the volume and then using a trangular spreader in circles | # Dilute Ecoli thawed stock to OD600 (absorbance at 600nm) of .08-.1 (specifically .812A) | ||
#Plate 100ul sample of diluted thawed Ecoli solution onto mueller hinton agar plates by first pipetting the volume and then using a trangular spreader in circles | |||
#Load 10ul of sample dilutions or control dilution onto their own individual 6mm Whatman membrane filter paper discs with tweezers | |||
-it was noted on 03/23/16 that loading 20ul onto the membrane filter paper discs took a very long time, and resulted in slight leakage when placed onto the plate, this time only load 10ul and see if there is still inhibition as to lessen the load on the filter paper discs | -it was noted on 03/23/16 that loading 20ul onto the membrane filter paper discs took a very long time, and resulted in slight leakage when placed onto the plate, this time only load 10ul and see if there is still inhibition as to lessen the load on the filter paper discs | ||
# place discs on plate, labeled so that dilution 1, is in a particular 5th of a plate (5 dilutions total) and immediately cover palte | |||
# incubate at 37˚C overnight in incubator and check results after 24 hours incubation | |||
Note that this technique was conducted on the benchtop. Between each loading of a disc on a plate, the tweezers used were washed with EtOH to minimize contamination. However, the plates were open to the air for a period of time during plating and loading of discs. Because we are testing for bacterial inhibition by the nanoparticles and control, if there is contamination, but inhibition we may never know that there was contamination in the first place. Discussed with Dr. Hartings and protocol was approved. | Note that this technique was conducted on the benchtop. Between each loading of a disc on a plate, the tweezers used were washed with EtOH to minimize contamination. However, the plates were open to the air for a period of time during plating and loading of discs. Because we are testing for bacterial inhibition by the nanoparticles and control, if there is contamination, but inhibition we may never know that there was contamination in the first place. Discussed with Dr. Hartings and protocol was approved. |
Latest revision as of 01:43, 27 September 2017
Project name | Main project page Previous entry Next entry | ||||||||||||||||||||||||||||||
Objectives
ProcedureMaterials for Agar Disc Diffusion
-autoclaved in dry cycle
AMP Table
Disc Diffusion Procedure
-it was noted on 03/23/16 that loading 20ul onto the membrane filter paper discs took a very long time, and resulted in slight leakage when placed onto the plate, this time only load 10ul and see if there is still inhibition as to lessen the load on the filter paper discs
Note that this technique was conducted on the benchtop. Between each loading of a disc on a plate, the tweezers used were washed with EtOH to minimize contamination. However, the plates were open to the air for a period of time during plating and loading of discs. Because we are testing for bacterial inhibition by the nanoparticles and control, if there is contamination, but inhibition we may never know that there was contamination in the first place. Discussed with Dr. Hartings and protocol was approved. Checking the discs
|