User:Daniel-Mario Larco/Notebook/AU Biodesign Lab - 09/03/2013/2014/02/26: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(Autocreate 2014/02/26 Entry for User:Daniel-Mario_Larco/Notebook/AU_Biodesign_Lab_-_09/03/2013)
 
No edit summary
Line 6: Line 6:
| colspan="2"|
| colspan="2"|
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
==Entry title==
==Procedures==
* Insert content here...
# Ocean Optics was used to perform continuous absorbance spectra in order to observe hemoglobin activity
##Solutions were prepared to run the Ocean Optics tests
### 3.0285mg of Tris were dissolved in 0.5L H2O, and pH was adjusted to 7.5 using 1N Hydrochloric acid
### 870.5mg of Sodium Dithionite were dissolved in 500mL of Tris buffer
# Both solutions were debased by placing a N<sub>2<sub/> line in the solutions for a few hours
# The data was collected then analyzed
 
 
==Data==
Graph showing how pure hemoglobin changes over time in the presence of Sodium Dithionite
[[Image:Hemoglobin control ocean.png|300px]]
This graph will be used as a basis for comparison of the nano particles coated with Hemoglobin
 
Graph showing absorbance changes in alpha hemoglobin nanoparticles over time
[[Image:Alpha Hemoglobin.png|300px]]
- In this graph we notice that the peak at around 400nm decreases but no new peak is formed, which suggests that something isn't right.
 
Graph showing absorbance changes in beta hemoglobin nanoparticles over time
[[Image:Beta hemoglobin ocean.png|300px]]
- In this graph we can see activity in the Beta-Method Hemoglobin coated AuNPs
 
 
<br>
<br>





Revision as of 16:47, 17 April 2014

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Procedures

  1. Ocean Optics was used to perform continuous absorbance spectra in order to observe hemoglobin activity
    1. Solutions were prepared to run the Ocean Optics tests
      1. 3.0285mg of Tris were dissolved in 0.5L H2O, and pH was adjusted to 7.5 using 1N Hydrochloric acid
      2. 870.5mg of Sodium Dithionite were dissolved in 500mL of Tris buffer
  2. Both solutions were debased by placing a N2 line in the solutions for a few hours
  3. The data was collected then analyzed


Data

Graph showing how pure hemoglobin changes over time in the presence of Sodium Dithionite This graph will be used as a basis for comparison of the nano particles coated with Hemoglobin

Graph showing absorbance changes in alpha hemoglobin nanoparticles over time

- In this graph we notice that the peak at around 400nm decreases but no new peak is formed, which suggests that something isn't right.

Graph showing absorbance changes in beta hemoglobin nanoparticles over time

- In this graph we can see activity in the Beta-Method Hemoglobin coated AuNPs