User:Dhea Patel/Notebook/Experimental Biological Chemistry Notebook/2012/10/03

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(Description)
Line 36: Line 36:
*The stock solutions for HAuCl<sub>4</sub>  and BSA were combined. The moles of each component were calculated in this "new stock" and the BSA needed was calculated so that the desired Au/BSA ratios could be obtained. Please refer to [[User:Melissa_Novy/Notebook/CHEM-571/2012/10/03| Melissa's entry]] for tables and specifics including moles, volumes, and edited protocol.  
*The stock solutions for HAuCl<sub>4</sub>  and BSA were combined. The moles of each component were calculated in this "new stock" and the BSA needed was calculated so that the desired Au/BSA ratios could be obtained. Please refer to [[User:Melissa_Novy/Notebook/CHEM-571/2012/10/03| Melissa's entry]] for tables and specifics including moles, volumes, and edited protocol.  
 +
 +
==Data==
 +
 +
[[Image:ADA_HisTrap_FPLC.PNG]]
 +
The UV-vis at 280nm of the elutent from the nickel column.
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 19:50, 4 October 2012

Search this Project

Customize your entry pages

Objective

  • to purify filtered protein through FPLC and
  • to remake Au/BSA solutions to run through Atomic Absorption.

Description

Purifying Protein via FPLC

  • The FPLC column was washed with 100mL binding buffer (pH 7.5 with Tris, NaCl, and 30mM of imidazol).
  • The filtered protein supernatant from yesterday was injected into the column.
  • The flow through from the column was collected in the same 50ml falcon tube that previously contained the protein supernatant as a precaution in case protein failed to bind to column.
  • 200mL elution buffer was pushed through the column while collecting the binded ADA protein in 5mL aliquots in separate test tubes.
    • NOTE: The nickel column binds to the histidine complex of Adenosine Deaminase (ADA) protein. Adenosine Deaminase is the only protein among protein supernatant with histidine complex. So theoretically, the ADA protein will be the only protein that sticks to the nickel column. The elusion buffer contains a high concentration of imidazole that competes with the nickel to bind to the histidine of the ADA protein. Theoretically, the ADA protein will be more attracted to the imidazole in the elusion buffer than the nickel in the column. Therefore, the ADA protein would flow through the column with the elusion buffer.
  • The AKTP purifier (that runs the FPLC) took real-time UV-vis at 280nm of the run through and elutent from the column. The 280nm peak indicates the presence of protein in the elutent. This UV-vis made it be feasible to identify the test tubes containing the ADA protein.
  • The ADA protein was collected in two 5mL test tubes and combined into a 15mL falcon tube. The falcon tubes were stored at 4°C.


Preparing Au/BSA Solutions of AA

  • The stock solutions for HAuCl4 and BSA were combined. The moles of each component were calculated in this "new stock" and the BSA needed was calculated so that the desired Au/BSA ratios could be obtained. Please refer to Melissa's entry for tables and specifics including moles, volumes, and edited protocol.


Data

Image:ADA_HisTrap_FPLC.PNG The UV-vis at 280nm of the elutent from the nickel column.


Personal tools