==Entry title==
+
==Objective==
-
* Insert content here...
+
* Run UV-vis and Fluorescence on p-sorbitol in phosphate buffer and mannitol in tris buffer samples in either MeOH, acetone, acetonitrile, ethyl acetate, water, or chloroform.
 +
==Description==
 +
*all the mannitol in tris buffer samples were vortexed and centrifuged before being measured
 +
*Centrifuge settings were as follows:
 +
**13200rpm
 +
**0:16 seconds
 +
**851 rotor
 +
*all the p-sorbitol in phosphate buffer samples were sonicated for 3 hours in their respective solvents.
 +
*Each solvent was used as a blank.
 +
*The data was corrected for the blank and a corrected baseline.
 +
*UV-vis scanned from 200-800nm
 +
*Fluorescence was run with an emission scan of 310-550nm at an excitation of 290nm and scan speed of 100nm/min.
 +
 +
'''Only MeOH and Acetone samples (for both mannitol in tris and p-sorbitol in phosphate) were run today. The rest of the samples will be run [[User:Dhea_Patel/Notebook/Hemoglobin_Project/2013/02/13|tomorrow]].'''
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 09:20, 13 February 2013

Project name Main project page
Previous entry      Next entry

Objective

  • Run UV-vis and Fluorescence on p-sorbitol in phosphate buffer and mannitol in tris buffer samples in either MeOH, acetone, acetonitrile, ethyl acetate, water, or chloroform.

Description

  • all the mannitol in tris buffer samples were vortexed and centrifuged before being measured
  • Centrifuge settings were as follows:
    • 13200rpm
    • 0:16 seconds
    • 851 rotor
  • all the p-sorbitol in phosphate buffer samples were sonicated for 3 hours in their respective solvents.
  • Each solvent was used as a blank.
  • The data was corrected for the blank and a corrected baseline.
  • UV-vis scanned from 200-800nm
  • Fluorescence was run with an emission scan of 310-550nm at an excitation of 290nm and scan speed of 100nm/min.

Only MeOH and Acetone samples (for both mannitol in tris and p-sorbitol in phosphate) were run today. The rest of the samples will be run tomorrow.