User:Elaine Marie Robbins/Notebook/CHEM-496/2012/02/14: Difference between revisions
From OpenWetWare
(Autocreate 2012/02/14 Entry for User:Elaine_Marie_Robbins/Notebook/CHEM-496) |
(→Data) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{|{{table}} width="800" | {|{{table}} width="800" | ||
|- | |- | ||
|style="background-color: # | |style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Absorbance vs Tris Concentration</span> | ||
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html> </html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}} | |||
|- | |||
| colspan="2"| | |||
| | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
< | |||
[[ | |||
|- | |||
|colspan="2"| | |||
==Objective== | |||
To continue the experiment performed on [[User:Elaine Marie Robbins/Notebook/CHEM-496/2012/02/01| 02/01/12]] to determine the effects of various concentrations of tris buffer on AuNP absorbance. | |||
==Description== | |||
# Take UV-vis data for various dilutions of tris buffer (pH 10.9) | |||
#* 1 M | |||
#* 500 mM | |||
#* 200 mM | |||
#* 100 mM | |||
#* 75 mM | |||
==Data== | |||
* Graph of absorbance vs wavelength for AuNP and different dilutions of tris | |||
<center>[[Image:Absorbance vs wavelength magnified.jpg]]</center> | |||
While all concentrations of tris buffer cause a peak shift towards shorter wavelengths, the higher concentrations tended to yield lower absorbance values. | |||
* Graph of peak absorbance vs -log(ionic strength of tris buffer solution). | |||
<center>[[Image:Peak absorbance vs -log(ionic strength) 2-14-12.jpg]]</center> | |||
* Graph of peak wavelength vs -log(ionic strength of tris buffer solution). | |||
* | |||
<center>[[Image:Peak wavelength vs -log(ionic strength) 2-14-12.jpg]]</center> | |||
==Notes== | ==Notes== | ||
[[Category:Course]] | [[Category:Course]] | ||
[[Category:Miscellaneous]] | [[Category:Miscellaneous]] | ||
Revision as of 12:50, 21 February 2012
Absorbance vs Tris Concentration | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
ObjectiveTo continue the experiment performed on 02/01/12 to determine the effects of various concentrations of tris buffer on AuNP absorbance. Description
Data
While all concentrations of tris buffer cause a peak shift towards shorter wavelengths, the higher concentrations tended to yield lower absorbance values.
Notes
|