User:Floriane Briere/Notebook/CHEM-496/2012/03/27: Difference between revisions
From OpenWetWare
(→Notes) |
m (→Objective) |
||
(7 intermediate revisions by the same user not shown) | |||
Line 11: | Line 11: | ||
==Objective== | ==Objective== | ||
Last week, we haven't been able to reproduce data we collected in | Last week, we haven't been able to reproduce data we collected in february for fluorescence spectrum; especially, the 166 ratio with dye solution gives very different results (it was the lowest curve in february but the highest last week). To try to explain this difference, we are going to measure pH of initial solutions (made in february) and compare it with the pH of second solutions (made in march). By comparing curves and pH, we are going to see whether or not it can explain the non reproducibility of our results. | ||
Line 42: | Line 42: | ||
# Increase the pH by adding Tris buffer: | # Increase the pH by adding Tris buffer: | ||
## 70 ratio with dye: add 6 drops, final pH = 8.29 | ## 70 ratio with dye: add 6 drops, final pH = 8.29 | ||
## | ## 166 ratio with dye: add 3 drops, final pH = 8.41 | ||
## | ## BSA/HCl ratio with dye: add 7 drops, final pH = 8.28 | ||
* Fluorescence spectrum of 3/21 solutions (2nd solutions). | * Fluorescence spectrum of 3/21 solutions (2nd solutions). | ||
Line 57: | Line 57: | ||
# 70 ratio alone: prepared on the 2/28 | # 70 ratio alone: prepared on the 2/28 | ||
# BSA/HCl alone: prepared on the 3/20 | # BSA/HCl alone: prepared on the 3/20 | ||
# Dye in solution: prepared in february (same as last time) | |||
* Take UV spectrum of all solutions. | |||
==Results== | ==Results== | ||
Line 63: | Line 66: | ||
[[Image:27mar - fluorescence curve 2nd solution.jpg]] | [[Image:27mar - fluorescence curve 2nd solution.jpg]] | ||
* Fluorescence spectrum: initial solutions. | |||
[[Image:27mar - fluorescence curve initial solution.jpg]] | |||
* Fluorescence spectrum: control solutions. | |||
[[Image:27mar - fluorescence curve control solution.jpg]] | |||
* UV spectrum: second solutions. | |||
[[Image:27mar - UV curve second solution.jpg]] | |||
[[Image:27mar - UV curve second solution zoom.jpg]] | |||
* UV spectrum: initial solutions. | |||
[[Image:27mar - UV curve initial solution.jpg]] | |||
[[Image:27mar - UV curve initial solution zoom.jpg]] | |||
* UV spectrum: control solutions. | |||
[[Image:27mar - UV curve control solution.jpg]] | |||
[[Image:27mar - UV curve control solution zoom.jpg]] | |||
==Notes== | ==Notes== |
Revision as of 07:53, 24 April 2012
Chem-496 | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
ObjectiveLast week, we haven't been able to reproduce data we collected in february for fluorescence spectrum; especially, the 166 ratio with dye solution gives very different results (it was the lowest curve in february but the highest last week). To try to explain this difference, we are going to measure pH of initial solutions (made in february) and compare it with the pH of second solutions (made in march). By comparing curves and pH, we are going to see whether or not it can explain the non reproducibility of our results.
We still miss the following data:
Protocol
Results
Notes
|