User:Helen L. Slucher/Notebook/CHEM 571/2013/10/01: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 16: Line 16:
## luminol (use stock solution)
## luminol (use stock solution)
## 3-aminophthalic acid (product of reaction between luminol and H2O2 catalyzed by HRP. In order to take this measurement, react (in 1:1 ratio or with slight excess H2O2) luminol with H2O2 in presence of HRP. Allow the reaction to proceed for 5 minutes; take the spectrum)
## 3-aminophthalic acid (product of reaction between luminol and H2O2 catalyzed by HRP. In order to take this measurement, react (in 1:1 ratio or with slight excess H2O2) luminol with H2O2 in presence of HRP. Allow the reaction to proceed for 5 minutes; take the spectrum)
# Kinetics of luminol oxidized by changes in absorption spectrum, reaction carried out in stopped flow mixer
## Add HRP/Luminol stock solution to stopped flow mixer
## Add H2O2 stock solution to stopped flow mixer
## equilibrate mixer tubes with sample.
## Initiate Mixing
## Using luminol and 3-aminophthalic acid spectra as endpoints, determine the kinetics of 3-aminophthalic acid synthesis.


==Data==
==Data==

Revision as of 15:27, 12 October 2013

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>


Objective

Monitor the kinetics and yield of the horseradish peroxidase-catalyzed oxidation of luminol.

Description

  1. UV-Vis Absorbance of reactants, catalysts, and products
    1. horseradish peroxidase (Use stock solution)
    2. luminol (use stock solution)
    3. 3-aminophthalic acid (product of reaction between luminol and H2O2 catalyzed by HRP. In order to take this measurement, react (in 1:1 ratio or with slight excess H2O2) luminol with H2O2 in presence of HRP. Allow the reaction to proceed for 5 minutes; take the spectrum)
  2. Kinetics of luminol oxidized by changes in absorption spectrum, reaction carried out in stopped flow mixer
    1. Add HRP/Luminol stock solution to stopped flow mixer
    2. Add H2O2 stock solution to stopped flow mixer
    3. equilibrate mixer tubes with sample.
    4. Initiate Mixing
    5. Using luminol and 3-aminophthalic acid spectra as endpoints, determine the kinetics of 3-aminophthalic acid synthesis.

Data

  1. Series 1: HRP Stock
  2. Series 2: 0.126mM Luminol
  3. Series 3: H2O2 Stock