User:Jamie Nunziata/Notebook/Protease Research/2015/10/20: Difference between revisions
(Autocreate 2015/10/20 Entry for User:Jamie_Nunziata/Notebook/Protease_Research) |
(fix raw html notebook nav) |
||
(2 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
== | ==Objective== | ||
* | |||
The objective of today's lab was to use a Fluorescence Assay to determine the rate a 100nM solution of a-chymotrypsin degrades AuNP fiber samples. | |||
==Procedure== | |||
7 samples of AuNP fibers were spun down at 300rpm for 10 minutes. These fibers will be used for our 120min, 90min, 60min, 45min, 30min, 15min, and 10min samples. 2.31µL of 43.359µM a-chymotrypsin (in phosphate buffer) and 997.7µL of phosphate buffer was added to each sample tube and a blank Eppindorf tube (no fibers), making a final solution of 100nM a-chymotrypsin. | |||
To each cuvette, the following was added: <br> | |||
*20uL of the blank or sample | |||
*140uL of Assay Buffer | |||
*40uL of Assay Reagent | |||
A full lab procedure can be found in Nicole Bonan's notebook entry for [[User:Nicole_Bonan/Notebook/Chem_571_Lab_Notebook/2015/10/20|today]] | |||
Fluorescence for each sample was measured between the emission spectrum from 400 to 600nm, and the data is recorded below | |||
==Data== | |||
[[Image:JMN_10_20_2015_BlankSample_Fluorescence.jpg]] | |||
[[Image:JMN_10_20_2015_SampleSlope_Fluorescence.jpg]] | |||
Latest revision as of 01:21, 27 September 2017
Project name | Main project page Previous entry Next entry |
ObjectiveThe objective of today's lab was to use a Fluorescence Assay to determine the rate a 100nM solution of a-chymotrypsin degrades AuNP fiber samples. Procedure7 samples of AuNP fibers were spun down at 300rpm for 10 minutes. These fibers will be used for our 120min, 90min, 60min, 45min, 30min, 15min, and 10min samples. 2.31µL of 43.359µM a-chymotrypsin (in phosphate buffer) and 997.7µL of phosphate buffer was added to each sample tube and a blank Eppindorf tube (no fibers), making a final solution of 100nM a-chymotrypsin.
Fluorescence for each sample was measured between the emission spectrum from 400 to 600nm, and the data is recorded below Data
|