There are three types of triggering on the TDS 1002 Digital Storage Oscilloscope.  According to [http://en.wikipedia.org/wiki/oscilloscopes#Triggered_sweeps Wikipedia], modern oscilloscopes use triggered sweep "to display events with unchanging or slowly changing waveforms, ...[which] may or may not be evenly spaced."


==AC Coupling==
==AC Coupling==

Revision as of 14:54, 31 August 2009

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Equipment

Tektronix TDS 1002 Digital Storage Oscilloscope BK Precision 4017A 10MHz Sweep/Function Generator BNC Cable

Setup

Plug both the oscilloscope and the function generator into a 120V AC wall outlet and connect the BNC cable to the output of the function generator and the CH1 lead on the oscilloscope. Turn on both the generator and oscilloscope.

Waveform Measurments

Wave 1
Set the generator to a sine wave at 200Hz. Measure the peak-peak voltage:
7.52V --measured by grid
7.52V --measured by cursors
7.52V --measured by oscilloscope


Wave 2
Set the generator to a sine wave at 75Hz. Adjust the output level slightly. Measure the peak to peak voltage:
9.90V --measured by grid
9.84V --measured by cursors
9.84V --measured by oscilloscope


Wave 3
Set the generator to a sine wave at about 7kHz. Adjust the output to a high level. Set the oscilloscope to acquire an average of 64 samples to remove the fluctuations in the wave towards the peaks. Measure the peak to peak voltage:
19.52V --measured by grid
19.56V --measured by cursors
19.5V --measured by oscilloscope.


Wave 4
Set the generator to a sine wave at 500Hz. Adjust the output to a low level.
3.72V --measured by grid
3.76V --measured by cursors
3.76V --measured by oscilloscope.


Wave 5
Leave the generator at 500Hz. Adjust the output to an high level. Set the generator to a large positive DC offset. Note that with sufficiently high DC offset the waveform seems to be displayed improperly. Specifically, it appears that the oscilloscope does not measure above 13V. As the DC offset is lowered, the waveform returns to a sinusoidal wave.

Triggering

There are three types of triggering on the TDS 1002 Digital Storage Oscilloscope. According to Wikipedia, modern oscilloscopes use triggered sweep "to display events with unchanging or slowly changing waveforms, ...[which] may or may not be evenly spaced."

AC Coupling

Acknowledgments

T. Mahony's Oscilloscope Lab Book for page format

Links

Physics307L
My OWW Page
My 307L Page