Line 11: | Line 11: | ||
*Enough plates, with right antibiotic, are available. Remove from cold storage, place in incubator for pre-heating. | *Enough plates, with right antibiotic, are available. Remove from cold storage, place in incubator for pre-heating. | ||
*Waterbath for heat shock is at right temperature (42 C). | *Waterbath for heat shock is at right temperature (42 C). | ||
*Ethanol for sterilization of glass spreader is available. (use absoulute ethanol). | |||
Before heat shock: Place plates in incubator for pre-heating. | Before heat shock: Place plates in incubator for pre-heating. | ||
Line 40: | Line 40: | ||
'''Preparing supercompetent cells:''' | '''Preparing supercompetent cells:''' | ||
*Centrifuge is cooled | *Centrifuge is cooled. Chill tube holders of the correct size by placing them in the centrifuge in advance. | ||
*Spectrophotometer and cuvettes for measuring OD are available | *Spectrophotometer and cuvettes for measuring OD are available | ||
*When using spectrophotometer: Correct wavelength is selected (600 nm) | *When using spectrophotometer: Correct wavelength is selected (600 nm) | ||
*For snap freezing: Dry ice or liquid nitrogen is available. | *For snap freezing: Dry ice or liquid nitrogen is available. | ||
*Freezer box is available | *Freezer box is available | ||
*Sterilize tubes for cell aliquots are available. | |||
*'''Freezer box is marked'''. | *'''Freezer box is marked'''. | ||
'''Electrophoresis:''' | '''Electrophoresis:''' | ||
* | *Imaging system is operational | ||
*After imaging: Save image as image file. Copy file(s) to personal area. | *After imaging: Save image as image file. Copy file(s) to personal area. | ||
*Remove gel from imaging apparatus. | *Remove gel from imaging apparatus. |
Revision as of 11:17, 3 June 2013
Checklists for lab procedures:
Start of day:
- Wipe down lab bench with ethanol.
Transformation:
- Supercompetent cells are available (remove from freezer 20 min before use, to avoid waiting for cells to thaw).
- Enough plates, with right antibiotic, are available. Remove from cold storage, place in incubator for pre-heating.
- Waterbath for heat shock is at right temperature (42 C).
- Ethanol for sterilization of glass spreader is available. (use absoulute ethanol).
Before heat shock: Place plates in incubator for pre-heating.
Restriction digest:
- Needed restriction enzymes are available.
- Thaw buffer
- Waterbath at 37 C is available. (or otherwise, thermomixer, or otherwise, shaking incubator)
Ligation:
- Ligation buffer is available.
- Ligase is available.
- Correct ligase is used (T4 DNA ligase)
- If possible include positive control to make sure the ligase is functional.
- If possible, include negative control of bacbone only/insert only, as appropriate.
Pipetting:
- Release plunger slowly to avoid air bubbles forming at the tip.
- When pipetting small volumes (enzyme reactions, etc.), confirm both that the right volume is drawn into and expelled from the pipette.
Preparation of agar plates:
- Magnetic stirrers are available
- Antibiotic is available. Thaw antibiotic.
Preparing supercompetent cells:
- Centrifuge is cooled. Chill tube holders of the correct size by placing them in the centrifuge in advance.
- Spectrophotometer and cuvettes for measuring OD are available
- When using spectrophotometer: Correct wavelength is selected (600 nm)
- For snap freezing: Dry ice or liquid nitrogen is available.
- Freezer box is available
- Sterilize tubes for cell aliquots are available.
- Freezer box is marked.
Electrophoresis:
- Imaging system is operational
- After imaging: Save image as image file. Copy file(s) to personal area.
- Remove gel from imaging apparatus.
- Copy image to document, write observations.
Gel extraction:
- The correct band is cut.
Measuring OD:
- Instrument is set to correct wavelength (typically 600 nm)
- Cultures are re-placed in incubator immediately after sampling.
- Enough liquid in cuvette
- Cuvette is inserted in correct orientation
Miniprep:
- Centrifuge is available
- Before centrifuging, measure OD600 is possible, for records on relation between culture properties and DNA yield.
- After measuring DNA concentration, record statistics (culture volume used, OD600, yield, etc.) for use in procedure optimization.
Use of instruments, general:
- After end of run/experiment, copy data to personal area.
- Print paper of copy of raw or processed data, place in ring binder or lab journal.
Inoculating cultures:
- A suitable incubator and tube rack / holder for the culture(s) is free.
Receiving plasmid samples for use:
- As soon as possible, verify the sequence (entirely, or critical parts only) for yourself
- Make a new glycerol stock for your personal use.
End of day:
- No samples are left on bench (that shouldn't be there).
- Update sample records
- Wipe down lab bench with ethanol.