*(1) Uchida Yoko e/m Experimental Apparatus Model TG-13
*
*(1) SOAR DC Power Supply Model PS-3630
*
*(1) SOAR DC Power Supply Model 7403
*
*(1) Gelman Instrument Company Deluxe Regulated Power Supply (no visible model number)
*
*(1) Fluke 111 True RMS Multimeter
*(2) Amprobe 37XR-A True RMS Multimeters
*(11) Pomona Electronics Banana Cables


===Lab===
The official lab procedure is on Pages 15-20 of [http://www-hep.phys.unm.edu/~gold/phys307L/manual.pdf this lab manual].
I connected the appropriate cables to the power supplies, and I connected a voltmeter in series to the Helmholtz coils' power supply. I had difficulty in getting the power supplies to work; they would not register any current, or very low current. Aram showed me that my circuit was not complete, and that I had to turn a current knob on the apparatus to get current to flow. Referring to Alexander T. J. Barron's notebook, Aram and I connected voltmeters to every device in the circuit. I still got odd readings in the high-voltage power supply, so I attempted to hook up a voltmeter to it, but I got a slight shock. I therefore turned the HV power supply off before hooking anything to it.


===Lab===
I connected the appropriate cables to the power supplies. I had difficulty in getting the power supplies to work; they would not register any current, or very low current. Aram showed me that my circuit was not complete, and that I had to turn a current knob on the apparatus to get current to flow.
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
|}
|}


__NOTOC__
__NOTOC__

Revision as of 15:49, 13 October 2008

PHYC 307L Junior Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Charge to Mass Ratio Lab 10/13/08

Equipment Used

  • (1) Uchida Yoko e/m Experimental Apparatus Model TG-13
  • (1) SOAR DC Power Supply Model PS-3630
  • (1) SOAR DC Power Supply Model 7403
  • (1) Gelman Instrument Company Deluxe Regulated Power Supply (no visible model number)
  • (1) Fluke 111 True RMS Multimeter
  • (2) Amprobe 37XR-A True RMS Multimeters
  • (11) Pomona Electronics Banana Cables

Lab

The official lab procedure is on Pages 15-20 of this lab manual.

I connected the appropriate cables to the power supplies, and I connected a voltmeter in series to the Helmholtz coils' power supply. I had difficulty in getting the power supplies to work; they would not register any current, or very low current. Aram showed me that my circuit was not complete, and that I had to turn a current knob on the apparatus to get current to flow. Referring to Alexander T. J. Barron's notebook, Aram and I connected voltmeters to every device in the circuit. I still got odd readings in the high-voltage power supply, so I attempted to hook up a voltmeter to it, but I got a slight shock. I therefore turned the HV power supply off before hooking anything to it.