User:Karlena L. Brown/Notebook/PVOH Research/2013/03/01

From OpenWetWare

< User:Karlena L. Brown | Notebook | PVOH Research | 2013 | 03(Difference between revisions)
Jump to: navigation, search
(Hydrogel Pressure Samples Tested 3)
Current revision (19:16, 14 April 2013) (view source)
(Straight Pippette: Hydrogel Pressure Samples Tested 3)
 
Line 9: Line 9:
* Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)
* Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)
-
==Straight Pippette: Hydrogel Pressure Samples Tested 3==
+
==Straight Pipette: Hydrogel Pressure Samples Tested 3==
'''RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13'''  
'''RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13'''  

Current revision

PVOH Research Main project page
Previous entry      Next entry

OBJECTIVES

  • Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)

Straight Pipette: Hydrogel Pressure Samples Tested 3

RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13

Sample Order PVOH vs. Clay Ratio PVOH Type Clay Selection Amount of Hydrogel Used (g)
150:50130K110% CEC NaMT w/ DMHXLBR0.1006
250:50130K110% CEC NaMT w/ DMHXLBR0.1022
390:10130KLaponite0.1031
450:50146K110% CEC Laponite w/ DMHXLBR0.1066
590:10130K110% CEC Laponite w/ DMHXLBR0.1083
690:10130K110% CEC NaMT w/ DMHXLBR0.1003
750:50130K110% CEC Laponite w/ DMHXLBR0.1036
850:50146KLaponite0.1016
990:10130K110% CEC NaMT w/ DMHXLBR0.1011
1090:10146K110% CEC NaMT w/ DMHXLBR0.1020
1150:50130KNaMT0.1024
1250:50130K50% CEC NaMT w/ Bu3HdP+0.1015
1350:50146K110% CEC NaMT w/ DMHXLBR0.0998
1490:10130K50% CEC NaMT w/ Bu3HdP+0.1026

Notes

  • The pipettes that provided the best fluorescence results for each sample were both the straight plastic and 90° angle bent pipettes.
  • All samples run maintained a composition incorporating Rhodamine 6G dye
  • All samples on 3/01/13 were tested using the straight pipette. (See figure listed below)