* Micropipets were used to transfer the Au/BSA solution from their test tube to the cuvette.
* Micropipets were used to transfer the Au/BSA solution from their test tube to the cuvette.
* One single cuvette was used for all UV-Vis scans to avoid fluctuations in the UV-Vis scan readings.
* One single cuvette was used for all UV-Vis scans to avoid fluctuations in the UV-Vis scan readings.
* During the UV-Vis scans, some of the fibers were stuck in the micropipet tips. These fibers were discarded. Hence, some of the volume of the Au/BSA solution were lost.  
* During the UV-Vis scans, some of the fibers were stuck in the micropipet tips. These fibers were discarded. Hence, some of the volume of the Au/BSA solution were lost. This may be the case; the volume lost is negligible.  


[[Image:AuBSAaug29edited.png]]
[[Image:AuBSAaug29edited.png]]

Revision as of 20:44, 14 September 2012

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

UV-Vis Spectroscopy of Aug. 29 Au/BSA solutions

  • In reference to the entry of Wednesday, August 29 (a week ago), the Au and BSA solutions were made using a metal spatula. Due to its hygroscopic nature, HAuCl4 reacted with the metal spatula.
  • The Au/BSA solutions of Aug. 29 were still examined using UV-Vis. The values for each mole ratio were plotted by its intensity vs. time using MS Excel.
  • Micropipets were used to transfer the Au/BSA solution from their test tube to the cuvette.
  • One single cuvette was used for all UV-Vis scans to avoid fluctuations in the UV-Vis scan readings.
  • During the UV-Vis scans, some of the fibers were stuck in the micropipet tips. These fibers were discarded. Hence, some of the volume of the Au/BSA solution were lost. This may be the case; the volume lost is negligible.

  • UV-visible scans of different Au/BSA mole ratios (batch August 29) incubated at 85 degrees Celsius for 4 h.


  • A closer view of the peaks of the UV-Visible scan of Au/BSA mole ratios from above.

Preparation of Au and BSA solutions

  • The metal spatulas used for preparation of stock solutions were wrapped with parafilm. This was done to inhibit HAuCl4 from reacting with the metal.
  • BSA solution was prepared by dissolving .0254 g of white crystalline powder of BSA in .025 L of water.

0.254 g of BSA × (1 mol of BSA ÷ 66430 g of BSA) = 3.82 × 10-7

3.82 × 10-7 ÷ .025 L of water = 1.53 × 10-5 mM/L

  • HAuCl4 stock solution was prepared by dissolving 0.0639 g of the orange, granular solid of HAuCl4 in .025 L of water.