* A rack of Au/BSA solutions was recovered and used for the assigned Atomic Absorption Spectroscopy (AAS). The entire solution set were observed to lack fibers even at high mole ratios where formation of fibers is typical. The date of which the solutions were made is unknown.
* A rack of Au/BSA solutions was recovered and used for the assigned Atomic Absorption Spectroscopy (AAS). AAS was used to strip the molecule to its elemental state.
* The entire solution set were observed to lack fibers even at high mole ratios where formation of fibers is typical. The date of which the solutions were made is unknown.
* The equipment used for AAS is by the make of Shimadzu AA-6200 Atomic Absorption Flame Emission.
* The equipment used for AAS is by the make of Shimadzu AA-6200 Atomic Absorption Flame Emission.
* The sample cell used for this procedure is the ignited flame.
* The sample cell used for this procedure is the ignited flame.
* A gold hollow cathode tube was selected for the procedure. The wavelength of the lamp was at 242.8 nm.
* A gold hollow cathode tube was selected for the procedure. The wavelength of the lamp was 242.8 nm.
*


<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 14:48, 23 October 2012

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Atomic Absorption Spectroscopy of Au/BSA

  • A rack of Au/BSA solutions was recovered and used for the assigned Atomic Absorption Spectroscopy (AAS). AAS was used to strip the molecule to its elemental state.
  • The entire solution set were observed to lack fibers even at high mole ratios where formation of fibers is typical. The date of which the solutions were made is unknown.
  • The equipment used for AAS is by the make of Shimadzu AA-6200 Atomic Absorption Flame Emission.
  • The sample cell used for this procedure is the ignited flame.
  • A gold hollow cathode tube was selected for the procedure. The wavelength of the lamp was 242.8 nm.