== | ==FPLC== | ||
Running FPLC in order to purify the Mn-Hb and the Ni-Hb. | |||
Here is a picture of the two variants prior to purification. (The Mn-Hb is in the more orange liquid and the Ni-Hb is in the more maroon liquid) | |||
[[Image:20130301 HbPhoto.jpg|400px]] | |||
For the purification, I am using the following buffers: | |||
Binding: 10mM Tris, 50mM NaCl, pH 8.5 | |||
Elution: 10mM Tris, 1M NaCl, pH 8.5 | |||
The Mn-Hb proceeded in a similar fashion to the WT-Hb, eluting at around 10% BufferB. | |||
The Ni-Hb was not purified with these conditions. Something stuck to the column, which there was much that passed through the column. The portion that stuck to the column could not be eluted with the elution buffer. I ran all of the solution through the column and collected the flowthru. | |||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> |
Revision as of 07:34, 7 March 2013
Protein Re-engineering | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
FPLCRunning FPLC in order to purify the Mn-Hb and the Ni-Hb. Here is a picture of the two variants prior to purification. (The Mn-Hb is in the more orange liquid and the Ni-Hb is in the more maroon liquid) For the purification, I am using the following buffers: Binding: 10mM Tris, 50mM NaCl, pH 8.5 Elution: 10mM Tris, 1M NaCl, pH 8.5 The Mn-Hb proceeded in a similar fashion to the WT-Hb, eluting at around 10% BufferB. The Ni-Hb was not purified with these conditions. Something stuck to the column, which there was much that passed through the column. The portion that stuck to the column could not be eluted with the elution buffer. I ran all of the solution through the column and collected the flowthru. |