User:Matthew R Skorski/Notebook/Cellulose Summer 2014/2014/06/23: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(One intermediate revision by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 15: Line 15:
Put large filament (from 6/18/2014) fragments into the extruder at 180°C.  The first approximately three feet were normal and smooth but the rest was very puffy.  Also to note the filament fragments clumped together in the hopper.  Had to press down on the them so the screw would break it up.   
Put large filament (from 6/18/2014) fragments into the extruder at 180°C.  The first approximately three feet were normal and smooth but the rest was very puffy.  Also to note the filament fragments clumped together in the hopper.  Had to press down on the them so the screw would break it up.   


Cut up the extruded filament into smaller pieces so it could be run through the extruder a second time.  The second time thought the extuder got the same problem of air bubbles in the filament.  Cut up the filament into even smaller fragements to see it that helped.  The 3rd extrusion ran into the same problem of the filament puffing up due to air bubbles.   
Cut up the extruded filament into smaller pieces so it could be run through the extruder a second time.  The second time thought the extuder got the same problem of air bubbles in the filament.  Cut up the filament into even smaller fragements to see it that helped.   


Made 7 mL of NH<sub>4</sub>-CNC solution, bringing the total up to 78 mL.         
Made 7 mL of NH<sub>4</sub>-CNC solution, bringing the total up to 78 mL.         

Latest revision as of 00:08, 27 September 2017

Project name Main project page
Previous entry      Next entry

Entry title

  • Purpose: To extrude the 20 g sample from 6/18/2014 through the extruder and create more NH4-CNC solution.

Safety and Procedure: See 6/6/2014 for column information

Experimental: The extruder would not turn on at first. After cleaning some metal filaments from the bottom and opening the sides to look the power would turn on if both the power button and heating button were switched on in that order.

Put large filament (from 6/18/2014) fragments into the extruder at 180°C. The first approximately three feet were normal and smooth but the rest was very puffy. Also to note the filament fragments clumped together in the hopper. Had to press down on the them so the screw would break it up.

Cut up the extruded filament into smaller pieces so it could be run through the extruder a second time. The second time thought the extuder got the same problem of air bubbles in the filament. Cut up the filament into even smaller fragements to see it that helped.

Made 7 mL of NH4-CNC solution, bringing the total up to 78 mL.