User:Melissa Novy/Notebook/CHEM-571/2012/09/19

From OpenWetWare

< User:Melissa Novy | Notebook | CHEM-571 | 2012 | 09(Difference between revisions)
Jump to: navigation, search
(Luminol Stock Solution in H2O and Carbonate Buffer)
Current revision (11:26, 9 October 2012) (view source)
(Notes)
 
Line 40: Line 40:
==Notes==
==Notes==
-
* Please refer to the [[Media:HRP_Assays.pdf|HRP assay]] report for all UV-vis and fluorescence spectra.
+
* Please refer to the [[User:Melissa_Novy/Notebook/CHEM-571/2012/09/25|entry on 2012/09/25]] for HRP-luminol fluorescence spectra and data analysis.
-
*'''[[User:Abigail E. Miller|Abigail E. Miller]] 18:03, 7 October 2012 (EDT)''':the report is not a substitute for your notebook. all data and results should be posted in your notebook. you then draw/drew from your notebook to write the report.
 
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
__NOTOC__
__NOTOC__

Current revision

Search this Project

Customize your entry pages

Objectives

  • Complete horseradish peroxidase enzymatic activity assay from 2012/09/18.
  • Make 2.5 mM luminol (MW 177.16) stock solution for horseradish peroxidase chemiluminescence assay.
  • Using a fluorimeter, collect emission spectra at 425 nm for horseradish peroxidase chemiluminescence assay.

Luminol Stock Solution in H2O and Carbonate Buffer

  • Calculations:
    • 10 mL of 2.5 mM luminol stock solution requires the following:
  MW luminol: 177.16 g/mol
  Mass luminol:
        10 mL × (10-3 L/mL) × (2.5 × 10-3 M) × (10-3 mol/mmol) × 177.16 g/mol = 0.00443 g luminol
  Actual mass luminol: 0.0044 g
  Actual concentration: 
        0.0044 g × (1 mol/177.16 g) × (1/0.010 L) = 2.5 × 10-3 M in H2O
  • The concentration of the luminol stock solution was varied by serial dilution as follows:
    • 1.25 mM, 625 μM, 312.5 μM, and 156.25 μM.
    • 10 mL solutions of each concentration were made.
  • Notes:
    • Luminol did not dissolve completely in H2O, so Na2CO3 was added in a ratio of 4 g for every 500 mL of solution to aid its dissolution.
      • 0.08 g of Na2CO3 was added to the luminol solution.
    • After the luminol dissolved, 0.48 g NaHCO3 was added to adjust the pH of the solution to about 7.
      • 0.48 g of NaHCO3 was added to the luminol solution.

Notes

  • Please refer to the entry on 2012/09/25 for HRP-luminol fluorescence spectra and data analysis.