* The solution was stirred for 1 h and then cast into a Teflon dish.
* The solution was stirred for 1 h and then cast into a Teflon dish.
* The dish was left under the fume hood to encourage evaporation of the dichloromethane.
* The dish was left under the fume hood to encourage evaporation of the dichloromethane.
 +
 +
==UV-Vis on ''E. coli'' Cells==
 +
* Absorbance was measured at 650 nm with a Shimadzu UV-1800 spectrophotometer using plastic cuvettes.  2 mL of each sample was pipetted into a clean plastic cuvette.
 +
* The absorbance of DH5α was 1.800.
 +
* The absorbance of DH10B was 1.82.

Revision as of 15:56, 6 February 2013

Search this Project

Customize your entry pages

Objectives

  • Make 50 mL 5 M KNO3 solution for ionic strength adjustments with silver ion-selective electrode.
  • Make LB/agar solution.
  • Make PLA2002D + 5wt% Laponite (PLA + 5LMT) using dichloromethane.

Calculations for 5 M KNO3

  MW KNO3: 101.10 g/mol
  0.050 L × 5 M KNO3 = 0.25 mol KNO3
  0.25 mol KNO3 × (101.10 g/1 mol KNO3) = 25.275 g KNO3
  • Actual mass KNO3: 25.2756 g
  • KNO3 was placed in a glass screw-top bottle and 50 mL of pure H2O was added. The solution was stirred and heated at 70°C for 3 hours to dissolve the KNO3.

PLA2002D + 5wt% Laponite Film

  • 1 g of PLA was dissolved in 10 mL of dichloromethane in a fume hood.
  • 0.05 g Laponite was dispersed in 5 mL of dichloromethane, and then added to the PLA solution.
  • The solution was stirred for 1 h and then cast into a Teflon dish.
  • The dish was left under the fume hood to encourage evaporation of the dichloromethane.

UV-Vis on E. coli Cells

  • Absorbance was measured at 650 nm with a Shimadzu UV-1800 spectrophotometer using plastic cuvettes. 2 mL of each sample was pipetted into a clean plastic cuvette.
  • The absorbance of DH5α was 1.800.
  • The absorbance of DH10B was 1.82.